Sun Microsystems 6900 Sun Proprietary/Confidential Internal Use Only, Value Description, encid12

Models: 6900 3900

1 204
Download 204 pages 8.57 Kb
Page 117
Image 117
Value Description

TABLE 8-1Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event Type

Severity

Action

Description

 

Action

 

 

 

 

 

 

 

interface.

Alarm-

Red

Y

The Sun StorEdge T3+

1.

Open a Telnet session

loopcard.cable

 

 

 

array has reported that a

 

to the affected Sun

 

 

 

 

loopcard is in a failed

 

StorEdge T3+ array.

 

 

 

 

state.

2.

Verify the loopcard

 

 

 

 

 

 

state with fru stat.

 

 

 

 

Possible Drive Status

3.

Verify the matching

 

 

 

 

Messages:

 

firmware with the

 

 

 

 

 

 

other loopcard.

 

 

 

 

Value Description

4.

Reenable the loopcard

 

 

 

 

0 Drive mounted

 

if possible (enable u

 

 

 

 

2 Drive present

 

(encid)[12] ).

 

 

 

 

3 Drive is spun up

5.

Replace the loopcard

 

 

 

 

4 Drive is disabled

 

if necessary.

 

 

 

 

5 Drive has been

6.

Reenable the disk if

 

 

 

 

replaced

 

possible

 

 

 

 

7 Invalid system area on

7.

Replace the disk, if

 

 

 

 

drive

 

necessary.

 

 

 

 

9 Drive not present

 

 

 

 

 

 

D Drive disabled; drive is

 

 

 

 

 

 

being reconstructed

 

 

 

 

 

 

S Drive substituted

 

 

 

 

 

 

 

 

 

power.battery

Alarm-

Red

Y

The state of the batteries

1.

Open a Telnet session

 

 

 

 

in the Sun StorEdge T3+

 

to the affected Sun

 

 

 

 

array is not optimal.

 

StorEdge T3+ array.

 

 

 

 

 

2.

Run refresh -s to

 

 

 

 

Possible causes are:

 

verify the battery

 

 

 

 

• The voltage level on

 

state.

 

 

 

 

the power supply and

3.

Replace the battery, if

 

 

 

 

the battery have moved

 

necessary.

 

 

 

 

out of acceptable

 

 

 

 

 

 

thresholds.

 

 

 

 

 

 

• The internal power

 

 

 

 

 

 

cooling unit (PCU)

 

 

 

 

 

 

temperature has

 

 

 

 

 

 

exceeded acceptable

 

 

 

 

 

 

thresholds.

 

 

 

 

 

 

• A PCU fan has failed.

 

 

 

 

 

 

 

 

 

Chapter 8 Troubleshooting the Sun StorEdge T3+ Array Devices 97

Sun Proprietary/Confidential: Internal Use Only

Page 117
Image 117
Sun Microsystems 6900, 3900 Sun Proprietary/Confidential Internal Use Only, Value Description, encid12, Run refresh -s to