Zone Modifications

The Sun StorEdge network FC switches in a Sun StorEdge 3900 or 6900 configuration now support the Sun StorEdge SAN 4.1 Release. You can upgrade the switches to support the 402xx 2 Gbit-compatible firmware.

Caution Use caution when upgrading back-end switches to the 2 Gbit-compatible firmware. Use only the setswitchflash command, which performs the upgrade and creates the zone configuration in a controlled manner (refer to the Sun StorEdge 3900 and 6900 Series 2.0 Reference and Service Guide for the procedures).

Zone Modifications

You should not modify the shared zone set on the back-end switches—doing so can cause an error (Error State 50) on the virtualization engine. If you determine, however, that you must modify the shared zone set, follow these steps:

1.Offline the T ports (interswitch links).

2.Offline the virtualization engine ports.

3.Modify the zone on one switch while the other switch continues to run.

4.Online the T ports (interswitch links).

5.Allow the zone database to merge.

6.Online the virtualization engine ports.

You can use the sanbox2(1M) command to offline the ports. For example:

#/opt/SUNWsecfg/flib/sanbox2 -x switch-ip-addr port -state offline

By default:

T ports are 6 7 14 15

Virtualization engine ports are 0 8