Be sure that you extend the bare copper wire down all branches of the system. Do not forget to connect the wires to each other with wire nuts when two branches meet at a “Y” or “T” connec- tion.
Ensure that the entire system is grounded. If using plastic blast gates to direct air flow, the grounding wire must be jumped (Figure 14) around the blast gate without interruption to the grounding system.
Plastic Blast Gate
Copper Ground Wire | Metal Duct |
|
Figure 14. Ground jumper wire when using plastic blast gates or elbows and metal duct.
We also recommend wrapping the outside of all plastic ducts with bare copper wire to ground the outside of the system against static electrical build up. Wire connections at Y’s and T’s should be made with wire nuts.
Attach the bare ground wire to each stationary woodworking machine and attach the canister dust collector frame with a ground screw as shown in Figure 15. Ensure that each machine is continuously grounded to the grounding terminal in your electric service panel.
Ground Screw
External Ground Wire
Internal Ground Wire
Figure 15. Flex-hose grounded to machine.
G0583 1 HP Canister Dust Collector |