Grizzly G0672, G0671, G0673 owner manual Flexible Duct, Plastic Duct

Page 29

There are quite a number of options when it comes to metal duct, but metal duct that is spe- cially manufactured for dust collection is the best choice. When selecting your metal duct, choose high quality metal duct with smooth welded inter- nal seams that will minimize airflow resistance. This type of duct usually connects to other ducts or elbows with a simple, self-sealing clamp, is very quick and easy to assemble, and can be readily dismantled and re-installed. This is espe- cially important if you ever need to change things around in your shop or add more machines. See the Accessories section on Page 35 for exam- ples.

Avoid inferior metal duct that requires you to cut it to length and snap it together. This type of duct is time consuming to install because it requires you to seal all the seams with silicone and screw the components on the ends with sheet metal screws. Another disadvantage is the rough internal seams and crimped ends that unavoidably increase static pressure loss.

Flexible Duct

Flexible hose is generally used for short runs, small shops and at rigid duct-to-tool connections. There are many different types of flex hose on the market today. These are manufactured from materials such as polyethylene, PVC, cloth hose dipped in rubber and even metal, including steel and aluminum.

The superior choice for flexible ducting is metal flex hose that is designed to be flexible and as smooth as possible to reduce static pressure loss.

Figure 25. Example of flexible metal duct.

G0671/G0672/G0673 Dust Collector

There are also many kinds of pure plastic flexible hose, such as non-perforated drainage type hose and dryer vent hose. Drainage type hose, while being economical, does not quite have the flex- ibility required for dust collection. The inside of the duct is also deeply corrugated and can increase the static pressure loss by as much as 50% over smooth wall duct. Dryer vent hose offers greater flexibility, but is non-resistant to abrasion and tends to collapse in a negative pressure system. We DO NOT recommend using dryer vent hose in your dust collection system.

If using flex-hose, choose one of the many types designed specifically for the movement of solid particles, i.e. dust, grains and plastics. However, the cost of specifically designed flexible duct can vary greatly. Grizzly offers polyethylene hose, which is well suited for the removal of particulate matter, especially sawdust, since it is durable and completely flexible. Polyethylene is also very eco- nomical and available in a wide variety of diam- eters and lengths for most applications.

Plastic Duct

The popularity of plastic duct is due to the fact that it is economical and readily available. It is also simple to assemble and easily sealed against air loss. The primary disadvantage of plastic duct for dust collection is the inherent danger of static electrical build-up.

Figure 26. Example of plastic duct and

components.

-27-

Image 29
Contents Dust Collector Ss ,EAD from Leadbased PAINTS Table of Contents Contact Info IntroductionForeword Functional Overview Identification Machine Data Sheet Main Specifications Operational Information Performance Curve Model G0672 HP Dust Collector Main Specifications Operational Information CFM Model G0673 HP Industrial Dust Collector Main Specifications Operational Information Model G0673 HP Dust Collector  !,7!93 53%3 %!2.2 02/4%#4/ %. /0%2!4.! -!#.%29  !,7!93 53% !.3 !002/6%$$ 3!&%49 ,!33%33 7%. /0%2!4 53%3 2%#/--%.$%$- !##%33/2%3  53%3!!2/5.$%$ %84%.3/..#/2$ 2!4%$4&/2/4%-!#.%!-0%2!%2 -!.9 -!#.%3 #!. %*%#4 7/2+0%#%3 4/7!2$ /0%2!4/2  !,7!93 ,/#+ -/,% !3%3 & 53%$ % %&/2% /0%2!4. -!#.%29#Additional Safety for Dust Collectors Operation Circuit RequirementsSetup Safety SetupItems Needed for Setup UnpackingG0671/G0672 Inventory Contents Figures 7 QtyFasteners where used not shown Qty G0673 Inventory Contents Figures QtyHardware Recognition Chart Placement Location AssemblySite Considerations Floor LoadCollector mounted to impeller Housing Upper filter bag secured to collector Page Test Run Metal Duct Designing SystemGeneral Duct Material Plastic Duct Flexible DuctDecide Who Will Design System DesignSketch Your Shop Layout Sketch a Basic Duct LayoutMachine Determine Required CFM of Each MachineMachine Approximate Determining Branch Line Duct Size Determining Main Line Duct SizeMultiple Dust Ports Two Machines on Same Branch LineDuct Approximate Dia Calculating Duct ResistanceLoss Per Foot Additional Factors Static Pressure LossPerformance Curve System Grounding General Operation Safety Basic ControlsOperations Metal Duct Starter Kit AccessoriesH2443-9 1⁄2 x 6 Universal Adapter Metal ElbowsReducers & Adapters Lubrication Bag Cleaning MaintenanceSchedule Daily CheckMotor & Electrical ServiceTroubleshooting Dust Collection Operation Symptom Possible CauseElectrical Safety Instructions WiringColor KEY G0671/G0672 Wiring DiagramSee Figure G0673 Wiring DiagramG0673 Electrical Components G0673 220V switchG0671 Parts Breakdown PartsDescription G0671 Parts ListG0672 Parts Breakdown G0672 Parts List G0673 Parts Breakdown G0673 Parts List G0671 G0672 G0673 Label Placement22!.49 #!2$ 99.$5342!, .# 0//88 %,,.!- 7!  Warranty and Returns #ALL 4ODAYD&ORO! &2%%