Test Run
Once the assembly is complete, test run your machine to make sure it runs properly and is ready for regular operation.
The test run consists of verifying the following: 1) The motor powers up and runs correctly, and 2) (Model G0673 only), the motor turns the correct direction (machine is not wired out of phase).
If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the machine immediately, then review the Troubleshooting on Page 38.
If you still cannot remedy a problem, contact our Tech Support at (570)
Before starting the dust collector, make sure you have performed the preceding assem- bly instructions, and you have read through the rest of the manual and are familiar with the various functions and safety features on this machine. Failure to follow this warn- ing could result in serious personal injury or even death!
To test run the machine:
1.Make sure you have read the safety instruc- tions at the beginning of the manual and that the machine is setup properly.
2.Make sure all tools and objects used during setup are cleared away from the machine.
3.Connect the machine to the power source.
4.Turn the machine ON by pushing in the GREEN button on the power switch.
5.Listen to and watch for abnormal noises or actions. The machine should run smoothly with little or no vibration or rubbing noises.
6.Turn the machine OFF by pushing in the RED button on the power switch.
7.Model G0673 Only: Verify that the power is not connected out of phase by starting/ stopping the machine and determining if the motor turns in the correct direction, using the criteria below:
G0671/G0672/G0673 Dust Collector |