SECTION 2: POWER SUPPLY
Availability
Before installing the machine, consider the avail- ability and proximity of the required power supply circuit. If an existing circuit does not meet the requirements for this machine, a new circuit must be installed. To minimize the risk of electrocu- tion, fire, or equipment damage, installation work and electrical wiring must be done by a qualified electrician in accordance with all applicable codes and standards.
Electrocution, fire, or equipment damage may occur if machine is not correctly grounded and connected to the power supply.
Full-Load Current Rating
The
14 | Amps | |
7 | Amps |
The
If the machine is overloaded for a sufficient length of time, damage, overheating, or fire may result— especially if connected to an undersized circuit. To reduce the risk of these hazards, avoid over- loading the machine during operation and make sure it is connected to a power supply circuit that meets the requirements in the following section.
Circuit Information
A power supply circuit includes all electrical equip- ment between the main breaker box or fuse panel in your building and the incoming power connec- tions at the machine. This circuit must be sized to safely handle the
For your own safety and protection of property, consult a qualified electrician if you are unsure about wiring practices or electrical codes in your area.
Note: The circuit requirements listed in this man- ual apply to a dedicated
Circuit Requirements for 110V
This machine is prewired to operate on a 110V power supply circuit that has a verified ground and meets the following requirements:
Nominal Voltage | 110V/120V |
Cycle | 60 Hz |
Phase | |
Circuit Rating | 15 Amps |
Plug/Receptacle | NEMA |
Circuit Requirements for 220V
This machine can be converted to operate on a 220V power supply. To do this, follow the Voltage Conversion instructions later in this section. The intended 220V circuit must have a verified ground and meet the requirements that follow:
Nominal Voltage | 220V/240V |
Cycle | 60 Hz |
Phase | |
Circuit Rating | 15 Amps |
Plug/Receptacle | NEMA |