Grizzly G0710 owner manual 110V Motor, 220V Motor, Paddle Switch

Page 26

Start

Capacitor

300MFD

125VAC

110V Motor

Paddle

 

Switch

Wt

 

Wt

 

 

110 VAC

Ground

5-15 Plug

 

Neutral

 

Wt

Wt

Hot

 

Ground

Start

Capacitor

300MFD

125VAC

220V Motor

Paddle

 

Switch

Wt

 

Wt

220 VAC

 

 

6-15 Plug

 

(As Recommended)

Ground

 

Wt

G

 

Wt

Hot

220

VAC

Hot

-24-

READ ELECTRICAL SAFETY

Model G0710 Dust Collector (Mfg. since 6/10+)

 

ON PAGE 23!

 

Image 26
Contents Model G0710 1HP Wall Hanging Dust Collector Page Table of Contents Contact Info IntroductionManual Accuracy Machine DescriptionMACHINe dATA SHeeT Impeller Information Safety Safety Instructions for MachineryUnattended OPERATION. Never­ leave­ Additional Safety Instructions for Dust Collectors Full-Load Current Rating Power SupplyAvailability Circuit InformationMinimum Gauge Size 12 AWG Grounding RequirementsExtension Cords 50 ftUnpacking SetupNeeded for Setup InventoryHardware Recognition Chart Site Considerations Assembly To assemble and mount the dust collectorDuct Grounding Collection SystemMaterial Selection Machine Average Dust Port Size Dust CollectionMachine Approximate Test Run To test run the machineOperations GeneralH7215-4 x 5 Rigid Metal Flex Hose G6163-4 Metal Hose Clamp AccessoriesG3181-Dust Collection Kit #1 H4340-0.3 Micron BagH6396-Small Downdraft Table H6397-Large Downdraft Table H2797-110V Shop Fox Remote ControlG0572-Hanging Air Filter With Remote Schedule MaintenanceBag Cleaning LubricationMotor & Electrical ServiceTroubleshooting Dust Collector Operation To Collection System beginning on Page 14 forWiring Wiring Safety Instructions220V Motor Paddle Switch110V Motor Parts MainMachine Labels Warranty Card CommentsGrizzly INDUSTRIAL, INC BOX BELLINGHAM, WAWarranty and Returns Warranty and ReturnsOrder Hours a DAY