Operation
CAUTION. Do not operate the extractor unless a hose is connected to the inlet port.
Switching on and off
1.Connect the plug to the power supply.
2.Depress the ON button.
3.To switch off, depress the OFF button.
NOTE.
1.The extractor must be connected to an earthed outlet and should be operated on a residual current device (RCD) of 30 mA capacity.
2.Extension leads must have a minimum lead cross section of 3 x 0.75 mm2 (240V).
3.The extractor is automatically turned off in the event of a power failure. You will need to press the ON button again to restart it.
Connecting the extractor to various tools and machines
1.Connect the small end of the large inlet hose (15) to the inlet port (11).
2.The 3 inlets of the vacuum distributor have an outer diameter of 35mm and inner diameter of 29mm.
3.You can connect up to 3 tools to the vacuum distributor. Use the caps supplied to cover the inlets that are not used. A single connection hose (14) is provided.
4.You can connect the
Maintenance
CAUTION. Always use a dust mask and safety goggles when carrying out any maintenance operation on this tool.
1.Keep the tool’s air vents unclogged and clean at all times.
2.Remove dust and dirt regularly. Cleaning is best done with a soft rag or a soft brush. Wear safety glasses to protect your eyes while cleaning.
3.Re-lubricate all moving parts at regular intervals.
4.If the body of the tool needs cleaning, wipe it with a soft, damp cloth. A mild detergent can be used, but nothing like alcohol, petrol or other cleaning agent.
5.Never use caustic agents to clean plastic parts.
CAUTION. Water must never come into contact with the tool.
General inspection
1.Regularly check that all the fixing screws are tight. They may vibrate loose over time.
Repairs
1.Only an authorised service centre should replace the cordset or effect other repairs. If the cordset is damaged or worm, have it repaired or replaced by an authorised service centre.
8