Powermatic PM1900TX manual Maintenance

Page 13

NOTE: The infrared sensor on the dust collector has a 120° line-of-sight angle. See Figure 12. Outside of this angle, the remote control may not be effective.

Figure 12

Setting the Timer (1-Phase Models)

While the machine is running, press the TIME button to activate the timer. Each time the button is pressed and released, the run time is incremented on the digital display by one minute and can be set up to 99 minutes.

If the TIME button is pressed and held, the time will scroll up to 99 minutes, then start again at

00.Release the button when the desired set time is reached. The dust collector will run for the amount of time displayed on the digital display. If you scroll past 99 and release the button at 10, for example, the machine will run for ten minutes, not 110 minutes.

If the OFF button is pressed while machine is running with the timer engaged, the machine turns off and the timer is disengaged; i.e., when the machine is restarted, the timer must be reset.

Connecting the Dust Collector to a Machine

Use the proper type hose to connect the dust collector to the machine being operated. Dryer vent hose is not acceptable for this purpose. Contact your nearest Powermatic distributor for a full line of Dust Collector hoses and accessories. You can customize your installation and obtain maximum performance with dust hoods, hoses, clamps, fittings, and blast gates.

Maintenance

Never perform maintenance on this machine before turning it OFF and removing plug from power source. Failure to comply may cause serious injury!

Cleaning the Filter Bags

Wearing a particle mask or respirator for protection against fine dust particles during cleaning is highly recommended.

During first use and after cleaning, the filter bags may allow some dust to escape. This is normal and will stop after a short period of time.

Clean both the filter and collector bags frequently to keep the collector's performance at its optimum. To clean:

1.Disconnect machine from the power source.

2.Unhook the filter bag from the hanger. Shake the bag so that the majority of the dust falls into the collector bag.

3.Loosen the retaining strap, and remove the filter bag from the housing.

4.Turn the bag inside-out and clean.

5.Turn the bag outside-in and re-attach to the housing using the retainer strap to secure.

Removing the Collector Bags

1.Disconnect machine from the power source.

2.Remove the collector bag by pushing the ring of the collector bag upwards and pulling the bag out at an angle.

3.Empty the contents into an appropriate container.

4.Turn the bag inside-out and clean.

5.Turn the bag outside-in and insert into the housing.

Cleaning the Canister Filters

Clean the canister filters frequently to keep the collector's performance at its optimum. To clean the filter, turn the handle a couple of rotations so the dust falls into the clear plastic bag. Properly discard the plastic bag.

Motor

Make frequent inspections of the motor fan and blow out (with low pressure air hose) or vacuum any accumulation of foreign material in order to maintain normal motor ventilation.

13

Image 13
Contents Part No. M-1792071 PowermaticWarranty Period Warranty and ServiceTable of Contents Page Page Introduction Specifications Unpacking Contents of Shipping CartonBase Machine Assembly Handles Cone InstallationFilter System Connect the upper hanger to the hanger support bar Figure Filter Bag System Assembly Retainer strap connection 17mm wrench required Canister System AssemblyElectrical Connections Disconnect from power source unplugOperating the Machine Extension CordsMaintenance Page Index No. Part No Description Size Qty Parts List for PM1900TX Dust Collector Base MachinePM1900-BMHP 1791075F Parts List and Breakdown for PM1900TX Filter Bag SystemBreakdown for PM1900TX Canister Filter System Parts List for PM1900TX Canister Filter System RSE Parte Nro. M-1792071 Del Colector de Polvo PM1900TXPeríodo de la Garantía Garantía y Servicio TécnicoPartes de Repuesto ÍndicePage Guarde Estas Instrucciones Introducción Especificaciones Contenido del Embalaje de Transporte DesempaqueContenido de la Bolsa de Partes Figura Asamblea de cono y hardware FiguraMontaje de la Máquina Base Montaje del Cono ManijasSistema de Filtros Figura Montaje del Sistema de Bolsa FiltroSe requiere una llave de 17mm Montaje del Sistema de CanastaOperación de la Máquina Conexiones EléctricasCables de Extensión Para convertir la tensión de operación de 230 a 460 VoltiosMantenimiento Page Nro. de Lista. Parte Nro Descripción Tamaño Cantidad Para 3HP, 230V, 1Ø 39-1 PM1900-139-1 1791075B Sistema de Colección y Bolsa Filtro incluye #1 al Despieze del Sistema Recipiente Filtro PM1900TX 1791086 Sistema de Recipiente Filtro incluye #1 a PM1900-301 Motor Pièce N. M-1792071 Dépoussiéreur PM1900TXPériode de garantie Garantie et entretienTable des matières Page Retenez CES Instructions Introduction Spécifications Contenu du carton dexpédition DéballageContenu du sac de matériel Figure Assemblée du cône et matériel FigureMontage de lengin de base Manches Cône InstallationSystème de filtre Connexion de la courroie de retenue Montage du système de sac-filtreClé de 17 mm requise Montage du système de boîte de filtrageConnexions électriques Sur les recommandationsUtilisation de la machine RallongesConnexion dun dépoussiéreur à une machine Réglage de la minuterie ModèleNettoyage de sacs-filtres Retrait des sacs du collecteurPage ’indice N de la pièce Description Taille Qté Liste de pièces du dépoussiéreur PM1900TX Machine de baseFor 3HP, 230V, 1Ph 39-1 PM1900-139-1 791 075B Page 1791087 Sac de collecteur en plastique Paquet de RSE