240 VOLT,

SINGLE PHASE OPERATION

The motor supplied with your tool is a dual voltage 120/240 volt motor. If it is desired to operate your dust collector at 240 volts, single phase, contact your local Authorized Delta Service Center or qualified electrician for proper procedures to rewire your dust collector motor for 240 volt operation and wiring a 240 volt attachment plug to the power supply cord.

The tool with a 240 volt plug should only be connected to an outlet having the same configuration as the plug illustrated in Fig. 26. No adapter is available or should be used with the 240 volt plug.

AS A PRECAUTION IN ALL CASES, MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED. IF YOU ARE NOT SURE, HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and a 3-hole receptacle which will accept the tool’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the tool. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Figs. 27 & 27A, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere

Volts

Total Length of

Gauge of

Rating

 

Cord in Feet

Extension Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

 

 

 

 

Fig. 27

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

HOLES

Fig. 24

HOLES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

Fig. 25

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

240 volt

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. 26

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere

Volts

Total Length of

Gauge of

Rating

 

Cord in Feet

Extension Cord

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

 

 

 

 

Fig. 27A

10

Image 10
Contents ½ H.P. Single-Stage Dust Collector General Safety Rules Additional Safety Rules for Dust Collectors Refer to them often Use them to instruct othersUnpacking and Cleaning Hardware not ShownAssembling Blower and Motor Assembly to Base AssemblyAssembling Casters to Base Page Page Assembling Filter and Dust Collection Bags to Drum Motor Specifications Connecting Tool to Power SourcePower Connections Grounding InstructionsExtension Cords Minimum Gauge Extension CordOperating Controls MaintenanceCircuit Breaker Accessories PARTS, Service or Warranty Assistance Two Year Limited WarrantyCanadian PORTER-CABLE Delta Service Centers