Grizzly H7678 instruction manual Troubleshooting, Symptom Possible Cause Solution

Page 17

TROUBLESHOOTING

Symptom

Possible Cause

Solution

Air leaking at trig-

1. O-rings in trigger valve hous-

1.

O-rings must be replaced

ger valve area.

 

ing are damaged.

 

& operation of safety yoke

 

 

 

 

must be checked.

 

 

 

 

Air leaking between

1. Loose screws in housing.

1.

Tighten screws.

housing and hose.

2. Damaged O-ring.

2.

Replace O-ring.

 

3.

Loose air fitting.

3.

Tighten air fitting & use tef-

 

 

 

 

lon tape.

 

 

 

 

Air leaking between

1. Damaged seal.

1.

Replace damaged seals.

housing and cap

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

Tool skips staples

1. Air leaks.

1.

Tighten screws and fittings.

while discharging.

2. Dirt in nose.

2.

Clean nose.

 

3.

Dirt or damage prevents

3.

Clean magazine and

 

 

staples from moving freely in

 

inspect/repair damage.

 

 

magazine.

 

 

 

4.

Inadequate air flow to tool.

4.

Check fitting, hose, com-

 

 

 

 

pressor & air pressure.

 

5.

Worn O-ring on piston or lack

5.

Replace piston O-ring.

 

 

of lubrication.

 

Lubricate.

 

6.

Damaged O-rings on trigger

6.

Replace trigger valve O-

 

 

valve.

 

rings.

 

7.

Worn bumper.

7.

Replace bumper.

 

8.

Cap seal leaking.

8.

Replace cap seal.

 

 

 

 

Tool runs slowly

1. Stapler is not sufficiently lubri-

1.

Lubricate stapler.

or has a loss of

 

cated.

 

 

power.

2. Broken spring in cap assem-

2.

Replace spring.

 

 

bly.

 

 

 

3.

Exhaust port in cap is blocked.

3.

Clean or replace damaged

 

 

 

 

internal parts.

 

 

 

 

Fasteners frequent-

1. Stapler is not sufficiently lubri-

1.

Lubricate stapler.

ly jam the stapler.

 

cated.

 

 

 

2.

Staples are the wrong size.

2.

Use correct staples.

 

3.

Staples are bent or dirty.

3.

Use undamaged, clean

 

 

 

 

staples.

 

4.

Magazine or nose screws are

4.

Tighten magazine.

 

 

loose.

 

 

 

5.

Driver or driver guide are worn

5.

Replace worn or damaged

 

 

or damaged.

 

parts.

 

 

 

 

Stapler does not

1. Staple is jammed in magazine

1.

Clear stapler magazine or

fire.

 

or discharge area.

 

discharge area.

 

2.

Piston shaft is damaged.

2.

Replace piston shaft.

 

3.

Air pressure too low.

3.

Check/increase air pres-

 

 

 

 

sure.

 

 

 

 

 

H7678 18 Gauge Deep Stapler Kit

-15-

Image 17
Contents Gauge Deep Stapler KIT Before Operating This Equipment SafetySafety Instructions For Pneumatic Tools H7678 18 Gauge Deep Stapler Kit Additional Safety Instructions for Staplers H7678 18 Gauge Deep Stapler Kit Contact Info IntroductionForeword UnpackingInventory SET UPCompressed Air System Disconnect Stapler from the AIR Supply Safety YokeOperating OperationsLoading Page Clearing Jammed Staples Replacing Pistons/O Rings CleaningLubricating Cleaning & LubricationH7678 Parts Breakdown Description H7678 Parts ListSymptom Possible Cause Solution TroubleshootingWarranty and Returns Warranty Card Place Stamp Here