Fedders CH18ABD1 warranty Introduction, Recognize Safety SYMBOLS, Words and Labels, Codes

Page 2

INTRODUCTION

You have made a major investment in a fine piece of equipment. Keep your investment sound by reading these instructions before installing this unit. This will ensure that the full potential of this equipment is achieved. It will also be helpful in avoiding any needless service costs or operational problems. Included in these instructions are safety rules, installation, operation, and maintenance instructions.

Only the highest quality components were used in the construction of your unit. With proper maintenance, your system should provide years of economical, trouble-free service.

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS

What You Need To Know About Safety

Instructions

Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.

Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

NOTES TO INSTALLER

The words “SHALL” and “MUST” indicate a requirement which is essential to satisfactory and safe product performance. The words “SHOULD” and “MAY” indicate a recommendation or advice which is not essential and not required but which may be useful or helpful.

Installation and service personnel are required by some locales to be licensed. Persons not qualified SHALL NOT install this equipment nor interpret these instructions.

This installation and maintenance manual is provided to ensure the proper installation and the most satisfactory performance of your equipment. The instructions contained herein SHALL NOT be deemed to extend, modify, alter or expand any of the representations contained in the limited warranty.

WARNING

A QUALIFIED INSTALLER MUST PERFORM INSTALLATION AND SERVICE.

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, MAINTENANCE OR USE CAN CAUSE EXPLOSION, FIRE, ELECTRICAL SHOCK OR OTHER CONDITIONS WHICH MAY CAUSE DEATH, PERSONAL INJURY OR PROPERTY DAMAGE AND WILL VOID THE WARRANTY. REFER TO THIS MANUAL FOR PROPER INSTRUCTIONS.

DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS OR OTHER COMBUSTIBLE MATERIALS IN THE VICINITY OF THIS OR ANY OTHER EQUIPMENT.

BEFORE PERFORMING ANY WORK ON THIS EQUIPMENT, POWER SUPPLY MUST BE TURNED OFF AT THE HOUSEHOLD SERVICE BOX TO AVOID THE POSSIBILITY OF SHOCK, INJURY, DAMAGE TO EQUIPMENT OR DEATH.

CONSULT A QUALIFIED INSTALLER FOR INFORMATION OR ASSISTANCE.

CODES

The installer SHALL comply with all local, state, and federal codes and/or regulations pertaining to this type of equipment and its installation. Such codes and/or regulations should take precedence over any recommendations contained herein in lieu of local codes. Installations SHALL be made in accordance with the National Electrical Code, local codes and recommendations made by the National Board of Fire Underwriters. Consult local building codes and National Electrical Code (NEC) for special requirements.

INSPECTION AND UNPACKING

A thorough inspection of the shipping container should be made immediately upon receiving your unit. Look for any punctures or openings and if it appears damage has occurred note it on the freight bill before signing. Contact the delivering carrier immediately to inspect damage, and no installation work should begin until this inspection is completed.

Locate rating plate on unit corner panel. It contains information needed to properly install unit. Check rating plate to be sure unit matches job specification.

11

Rating plate located inside control box cover

1

Image 2
Contents Table of Contents Through 5 Ton Heat PumpIntroduction Recognize Safety SYMBOLS, Words and LabelsWhat You Need To Know About Safety Instructions CodesElectrical Connections InstallationCondensing Unit Location 114Service Valve Connections 117118 PrecautionsConnect Refrigerant Piping Liquid Line SizesSUB-COOLING Charging Final Checks for InstallerModel Cooling OperationMaintenance Instructions Defrost OperationLimited Warranty Model C10

CH18ABD1 specifications

The Fedders CH18ABD1 is a powerful and efficient air conditioning unit that is designed for residential and light commercial applications. This model is particularly popular for its ability to deliver rapid cooling and heating, making it an ideal choice for various climates and seasonal changes.

One of the standout features of the Fedders CH18ABD1 is its robust 18,000 BTU cooling capacity. This allows it to efficiently cool large spaces, making it suitable for medium to large rooms. The unit also offers a heating capacity, which provides flexibility for year-round comfort. The ability to switch between cooling and heating modes allows users to enjoy a comfortable indoor environment no matter the weather outside.

The Fedders CH18ABD1 is designed with advanced technologies that enhance its efficiency and performance. A key technology is its use of a high-efficiency compressor, which significantly reduces energy consumption while maintaining effective temperature control. Additionally, this model includes a programmable thermostat that allows users to set precise temperatures and schedules, promoting energy savings and convenience.

In terms of noise levels, the Fedders CH18ABD1 operates quietly, making it suitable for settings where noise is a concern, such as bedrooms or offices. The unit’s design incorporates sound-dampening features that minimize operational sound, ensuring an unobtrusive climate control experience.

Installation and maintenance of the Fedders CH18ABD1 is relatively straightforward. The unit is designed for easy mounting in windows or through walls, providing flexibility in placement. Regular maintenance is facilitated by accessible filters that can be easily cleaned or replaced, helping sustain optimal performance over time.

Furthermore, the unit is equipped with various modes, such as fan-only and auto-restart functions. The fan mode allows for air circulation without cooling, while the auto-restart function ensures the unit resumes its previous settings after a power outage.

In summary, the Fedders CH18ABD1 stands out for its powerful cooling and heating capabilities, advanced efficiency technologies, and user-friendly features. Its flexible operation, quiet performance, and ease of maintenance make it a reliable choice for anyone seeking an effective and efficient air conditioning solution. This unit is an excellent investment for those aiming to maintain a comfortable living environment throughout the year.