CONNECT REFRIGERANT PIPING

The following should be followed when installing refrigerant piping. Comply with all local, state, and federal codes and/or regulations pertaining to this type of equipment and its installation.

1.Run the tubing by the most direct route and support every few feet. Do not run the lines underground unless they are in a chase. Leave enough material between structure and unit to absorb vibration.

2.Insulate the vapor line to prevent sweating and line loss. In underground chases, the vapor line should be insulated to provide vibration isolation between the vapor and liquid line. A minimum of 3/8” insulation is recommended in conditioned space and 1/2” to 3/4” in unconditioned space. Ensure that tubing insulation is pliable and completely surrounds vapor tube.

3.In general, the piping should be sloped toward the outdoor unit to prevent oil trapping. Where vertical risers occur, a suction line trap should be located at the base of the riser to assure proper oil return.

WARNING

REFRIGERANT LINE LENGTH MUST NOT EXCEED 75’ ON HORIZONTAL RUNS AND 40’ ON VERTICAL RISERS.

Precautions

Refer to the chart below for the minimum recommended tube outside diameter sizes on liquid and suction lines. Ensure that vapor and liquid tube diameters are appropriate for unit capacity. Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.

Undersized line sets will increase the refrigerant pressure drop between the indoor evaporator and outdoor unit, resulting in a decrease in system capacity. Oversizing the line sets may result in excessive refrigerant charge, thereby making the system more susceptible to liquid migration.

When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon based caulk

Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls

Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing

When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation

Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation

Condensing units are available with pre-charged, sweat-type copper connecting fittings

Units are factory charged for 15’ of line set tubing.

 

 

 

118

 

OUTDOOR

 

 

 

LIQUID

 

SECTION

 

 

 

 

LINE

 

 

 

20’

Can only be

 

 

20’ vertical

 

 

 

 

INDOOR

 

separation

 

COIL

 

without

 

 

 

additional

 

SUCTION

 

accessories.

 

LINE

 

 

 

WARNING

 

 

 

IF THE INSTALLER IS MAKING UP HIS OWN LINE SETS, HE MUST MAKE SURE THE TUBING IS CLEAN OF ANY IMPURITIES OR MOISTURE. USE ONLY CLEAN AIR CONDITIONING AND REFRIGERATION GRADE SEAMLESS COPPER TUBING. PLUMBING GRADE COPPER IS INADEQUATE. TO ENSURE A CLEAN SYSTEM FREE OF ANY CONTAMINANTS, PURGING WITH DRY NITROGEN AND A DEEP VACUUM IS NECESSARY ON ALL SWEAT-TYPE MODELS AND ON THE UNCHARGED PORTIONS OF ALL MODELS NOT INCORPORATING PRECHARGED LINES. IT IS DESIRABLE TO PULL A VACUUM TO 1,000 MICRONS (29.96”

HG) TO ENSURE TROUBLE FREE OPERATION.

Adjust charge 0.66 oz per foot of variation from chart for 3/8” and 3/4” line set.

Adjust charge 0.67 oz per foot of variation from chart for 3/8" and 7/8" line set.

Adjust charge 0.72 oz per foot of variation from chart for 1/2" and 1 1/8" line set.

Liquid Line Sizes

HEAT PUMP

 

LINE SET LENGTH AND SIZE

 

 

 

 

 

 

 

MODEL

15 FT

 

25 FT

50 FT

 

75 FT

NUMBER

 

 

LINE SET

 

LINE SET

LINE SET

 

LINE SET*

 

 

 

 

 

 

 

 

 

 

CH18ABD1

3/8”

 

3/8”

3/8”

 

3/8”

 

 

 

 

 

 

 

CH24ACD1

3/8”

 

3/8”

3/8”

 

3/8”

 

 

 

 

 

 

 

CH30ACD1

3/8”

 

3/8”

3/8”

 

3/8”

 

 

 

 

 

 

 

CH36ACD1

3/8”

 

3/8”

3/8”

 

3/8”

CH42ACD1

3/8”

 

3/8”

3/8”

 

3/8”

 

 

 

 

 

 

 

CH48ACD1

3/8”

 

3/8”

1/2”

 

1/2”

 

 

 

 

 

 

 

Suction Line Sizes

HEAT PUMP

 

LINE SET LENGTH AND SIZE

 

 

 

 

 

MODEL

15 FT

 

25 FT

50 FT

75 FT

NUMBER

 

LINE SET

 

LINE SET

LINE SET

LINE SET*

 

 

 

 

 

 

 

 

CH18ABD1

3/4”

 

3/4”

3/4”

3/4”

 

 

 

 

 

 

CH24ACD1

3/4”

 

3/4”

3/4”

3/4”

 

 

 

 

 

 

CH30ACD1

7/8”

 

7/8”

7/8”

7/8”

 

 

 

 

 

 

CH36ACD1

7/8”

 

7/8”

7/8”

7/8”

CH42ACD1

7/8”

 

7/8”

7/8”

1 1/8”

 

 

 

 

 

 

CH48ACD1

7/8”

 

1 1/8”

1 1/8”

1 1/8”

 

 

 

 

 

 

* DO NOT EXCEED 75 FT MAXIMUM LINE SET LENGTH

4

Image 5
Contents Through 5 Ton Heat Pump Table of ContentsWhat You Need To Know About Safety Instructions Recognize Safety SYMBOLS, Words and LabelsIntroduction CodesCondensing Unit Location InstallationElectrical Connections 114117 Service Valve ConnectionsConnect Refrigerant Piping Precautions118 Liquid Line SizesModel Final Checks for InstallerSUB-COOLING Charging Cooling OperationDefrost Operation Maintenance InstructionsModel C10 Limited Warranty

CH18ABD1 specifications

The Fedders CH18ABD1 is a powerful and efficient air conditioning unit that is designed for residential and light commercial applications. This model is particularly popular for its ability to deliver rapid cooling and heating, making it an ideal choice for various climates and seasonal changes.

One of the standout features of the Fedders CH18ABD1 is its robust 18,000 BTU cooling capacity. This allows it to efficiently cool large spaces, making it suitable for medium to large rooms. The unit also offers a heating capacity, which provides flexibility for year-round comfort. The ability to switch between cooling and heating modes allows users to enjoy a comfortable indoor environment no matter the weather outside.

The Fedders CH18ABD1 is designed with advanced technologies that enhance its efficiency and performance. A key technology is its use of a high-efficiency compressor, which significantly reduces energy consumption while maintaining effective temperature control. Additionally, this model includes a programmable thermostat that allows users to set precise temperatures and schedules, promoting energy savings and convenience.

In terms of noise levels, the Fedders CH18ABD1 operates quietly, making it suitable for settings where noise is a concern, such as bedrooms or offices. The unit’s design incorporates sound-dampening features that minimize operational sound, ensuring an unobtrusive climate control experience.

Installation and maintenance of the Fedders CH18ABD1 is relatively straightforward. The unit is designed for easy mounting in windows or through walls, providing flexibility in placement. Regular maintenance is facilitated by accessible filters that can be easily cleaned or replaced, helping sustain optimal performance over time.

Furthermore, the unit is equipped with various modes, such as fan-only and auto-restart functions. The fan mode allows for air circulation without cooling, while the auto-restart function ensures the unit resumes its previous settings after a power outage.

In summary, the Fedders CH18ABD1 stands out for its powerful cooling and heating capabilities, advanced efficiency technologies, and user-friendly features. Its flexible operation, quiet performance, and ease of maintenance make it a reliable choice for anyone seeking an effective and efficient air conditioning solution. This unit is an excellent investment for those aiming to maintain a comfortable living environment throughout the year.