Jet Tools PDS-12CS owner manual Disconnect the machine from the power source

Page 6

230 Volt Operation

If 230V, single phase operation is desired, the following instructions must be followed:

1.Disconnect the machine from the power source.

2.This POWERMATIC sander is supplied with four motor leads that are connected for 115V operation, as shown in Figure A. Reconnect these four motor leads for 230V operation, as shown in Figure B.

3.The 115V attachment plug (A), supplied with the sander, must be replaced with a UL/CSA listed plug suitable for 230V operation (D). Contact your local Authorized POWERMATIC Service Center or qualified electrician for proper procedures to install the plug. The sander must comply with all local and national codes after the 230 volt plug is installed.

4.The sander with a 230 volt plug should only be connected to an outlet having the same configuration

(D). No adapter is available or should be used with the 230 volt plug.

Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly grounded. If you are not sure, have a registered electrician check the receptacle.

6

Image 6
Contents PDS-12CS 12 Disc Sander Warranty & Service Volts Total Length of Cord in Feet AWGPage Grounding Instructions Volt OperationDisconnect the machine from the power source Specifications Table of ContentsContents of the Shipping Carton Tools Required for Assembly & AdjustmentsUnpacking Stand Assembly Sander AssemblyCollector Bag Assembly Table AdjustmentCenter Point Sanding Disc ReplacementOn/Off Switch Filler BarOptional Accessories Troubleshooting Possible Cause SolutionBase Assembly Breakdown Parts List for the PDS-12CS Base Assembly Index Part Description Size QtySander Assembly Breakdown Parts List for PDS-12CS Sander Assembly PDS12CS-RCPDS12CS-HK Wiring Diagram