Heath Zenith installation instructions Model SL-5656

Page 1

Model SL-5656

Compact Fluorescent Dusk-to-Dawn 70 Watt Security Light

Installation Instructions

READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.

NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system.

Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.

Photocontrol

Ground Screw

Lens/Reflector

Assembly

Cover Plate

Fixture Wires Thru

This Hole

WARNING: Turn power off at the fuse or circuit breaker.

1.Select a location on a flat wall with structurally sound wood and from 10 to 25 feet (3 to 7.6 m) from the ground. The wood should be at least one inch thick to safely secure the fixture.

2.Using the mounting template as a guide, mark the 3 mounting holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the lag screws.

3.Install the two bottom lag screws first. Screw in the lag screws so that there is about 3/8" (9.5 mm) of space under the head.

4.Place the fixture on these two screws and install the top lag screw. Tighten the top lag screw first, then tighten the remaining lag screws.

5.Secure your outdoor cable or flexible conduit to the cover plate with a fitting in accordance with the National Electrical Code (Canadian Electrical Code in Canada).

6.Thread the black and white fixture wires through the hole in the cover plate as shown.

7.Connect the fixture wires to the service wires (black to black and white to white).

8.This fixture must be connected to ground. Secure the service ground wire under the head of the green ground screw.

9.Install the cover plate. Secure with the two screws, washers, and nuts provided.

10.Install the reflector/lens assembly. Secure with the two screws provided.

11.Plug in the 70 watt compact fluorescent lamp provided (NEMA designation CFTR70W/GX24Q with GX24Q-6 base).

Note: A 57 watt compact fluorescent lamp can also be used with this fixture. The NEMA designation is CFTR57W/GX24Q with GX24Q-5 base.

CAUTION: Do not use any other wattage lamps in this fixture.

ATTENTION: When removing, grasp bulb by the base. Do not grasp glass bulb to remove.

To test operation during daylight, cover the photocontrol with black electrical tape. Turn on the power. The light should come on immedi- ately and will take up to ten minutes to reach full brightness. Uncover the photocontrol and your unit will operate automatically—on at dusk, off at dawn.