Heath Zenith 52-4474-4 Manual Mode, Mode Switching Summary, Adjustment of Coverage Area

Page 6

The sensor is less sensitive to motion directly towards it and more sensitive to motion across coverage area.

MotionMotion

 

Sensor

 

 

Least Sensitive

Most Sensitive

 

OPERATION

 

 

 

 

 

 

Mode:

On-Time

 

Works: Day

Night

Test

5 Seconds

 

x

x

Auto

1, 5, or 10

 

 

x

 

Minutes

 

 

 

Manual

To Dawn*

 

 

x

* resets to Auto Mode at dawn.

Note: When firstturned on wait about 1 1/2 minutes for the circuitry to calibrate.

MANUAL MODE

Mode Switching Summary

 

TEST

 

 

 

ON-TIME Switch at 1, 5, or 10

 

 

 

 

 

 

 

 

 

 

 

 

 

minutes

 

AUTO

 

 

 

 

Fliplightswitchoffforone

 

 

 

 

 

 

 

 

 

 

 

 

second then back on*

MANUAL MODE

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

Adjustment of Coverage Area

The sensor on this light fixture detects “motion” by the movement of heat across the coverage area. However, following are examples of objects that also produce heat and can cause the sensor to trigger:

• Pools of Water

• Air Conditioners

• Dryer Vents

• Animals

• Heating Vents

• Automobile Traffic

If you suspect that a heat source of this type is triggering the sensor, reduce the sensitivity.

 

SPECIFICATIONS

Range

................................Up to 30 ft.(9.1 m) [varies with

 

surrounding temperature].

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one sec- ond then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

Sensing Angle

180°

Electrical Load

Up to 100 Watt Maximum

 

Tungsten Incandescent

Bulb Type

Medium Base, Type “A”, 100

 

Watt Maximum

Sensor Capacity

360 Watt (3.0 A) Maximum

 

Tungsten Incandescent

Power Requirements

120 VAC, 60 Hz

Operating Modes

TEST, AUTO, and MANU-

 

AL MODE

ON-Timer

1, 5, 10 minutes

... back on.

Test Timer

5 Seconds

Manual Mode Timer

Dusk-to-Dawn

598-1286-01

Image 6
Contents Requirements FeaturesLantern Assembly UnpackingInstallation WiringRecommended Grounding Method Optional Wiring Install one medium base light bulb 100 Watt maxi- mum Final AssemblyTesting and Adjustments Set ON-TIME switch to Test Sensitivity dial to MidwayAdjustment of Coverage Area Manual ModeMode Switching Summary SpecificationsTroubleshooting If you experience a problem, follow this guideDéballage CaractéristiquesExigences Assemblage DE LA LanterneCâblage AVERTISSEMENTNEPASraccorderlefilROUGEVis de terre GND sur la plaque de montage Code du bâtimentCâblage Facultatif Supérieure à 360 W 3,0 aAssemblage Final Essais ET RéglagesPriorité Manuelle Revient au mode automatique au lever du soleilFonctionnement Réglage DE LA Zone DE CouvertureFiche Technique Dépannage598-1286-01 598-1286-01