Fedders A6X05F2G Power Cord with Arc Detection Device, Electrical Shock Hazard, Resetting

Page 2

Room Air Conditioner

Power Cord with Arc Detection Device

The power cord supplied with this air conditioner is equipped with an Arc Detection Device designed to shut off power to the unit when it senses an arc fault condition. An arc fault is an unintentional electrical discharge that occurs when electrical products or wires are damaged, aged, or improperly used. An arc fault can be potentially hazardous if left undetected.

WARNING

Do not remove or modify this plug

Do not use as an on/off switch

Do not use outdoors

Do not push furniture against or place furniture on the electrical cord. This can trip the test switch and/or damage the cord and become a potential condition for arcing

Do not attempt to repair the cord. If the cord requires replacement, call an authorized servicer.

The Arc Detection Device is not a Ground Fault Interrupter and should not be used as such

The Arc Detection Device contains an electronic circuit board and should not be submerged or exposed to water spray

Resetting

If the Arc Detection Device has tripped, the reset button will pop up.

Follow these steps to reset the Arc Detection Device:

1.Unplug unit from electrical outlet

2.Press the reset button

3.Plug the unit back into electrical outlet

4.Check to see if power has returned to the unit

Testing

You should test the Arc Detection Device equipped power cord monthly, after every major electrical storm, or if power to your Room Air Conditioner has been interrupted.

Follow these steps to test the Arc Detection Device:

1.Unplug unit from electrical outlet

2.Press the reset button

3.Plug the unit back into electrical outlet

4.Press test button.

Unit should trip and reset button will pop up.

5.Press reset button again for use

If above test fails, stop using the air conditioner and contact customer service by calling the following toll- free number:

1-800-332-6658

or email: customerservice@fedders.com

WARNING

Do not operate this air conditioner without proper time delay circuit protection (circuit breaker or fuse). Refer to serial plate for proper power supply requirements.

Recommended Wire Sizes

(As installed per building code) :

PROTECTOR SIZEWIRE

GAUGE 15 AMP #14 MINIMUM

20 AMP #12 MINIMUM

125V

250V

250V

250V

30 AMP #10 MINIMUM

15A

20A

15A

30A

 

 

 

 

WARNING

Electrical Shock Hazard

• Plug unit only into a grounded electrical outlet.

Do not use an extension cord or plug adapter with this unit.

Do not operate unit with decorative front or filter removed.

Failure to follow these precautions could result in electrical shock, fire or personal injury.

If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps, it must have its own fuse or circuit breaker, and no other device or unit should be operated on that fuse or circuit breaker.

If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on that fuse or circuit breaker.

We recommend that a qualified electrician install unit in accordance with the National Electrical Code and local codes and ordinances.

Use copper conductors of correct wire gauge and protector size only.

Do not alter cord or plug end. Do not remove warning label on cord.

Important Grounding Requirements

Air conditioner has a three-prong grounding plug on the power supply cord, which must be plugged into a properly grounded three-prong wall receptacle for your protection against possible shock hazard. For models up to and including 7.5 amperes, use a grounding type wall receptacle to match the cord plug.

For models above 7.5 amperes use a single outlet grounding type wall receptacle to match the cord plug.

1

Image 2
Contents Pour dautres questions For additional questions please callPara mayor información por favor llame al Testing Power Cord with Arc Detection DeviceResetting As installed per building codeInstallation in window 23 to 34 wide Additional Safety PrecautionsFiller Panel Installation Window RequirementsInstallation in window 19 to 22 wide Timer Control Decorative Front Removal Air Conditioner Remote ControlCleaning the Air Filter Air from unit does not Proof of Purchase Date Limited One Year WarrantyExceptions For Additional AssistanceRequerimientos Importantes para la Puesta a Tierra Cordón con dispositivo de detección de arco eléctricoRiesgo de Choque Eléctrico Tamaños Recomendados de los conductores del circuitoPrecauciones de Seguridad Adicionales Requisitos de la ventanaInstalación del panel de relleno Partes de InstalaciónTornillos para madera de 1,59cm 5/8 pulg Controles de temperatura/hora Control de alimentaciónPantalla de temperatura/hora Control de modoPara retirar el frente decorativo Control Remoto de Acondicionador de AireLimpieza del filtro de aire Localización y Solución de Averías Garantía limitada de un año Customerservice@fedders.comGarantía del Acondicionador de Aire Individual ExcepcionesTests Cordon électrique avec dispositif de détection darcRéarmement Liaison à la terre Exigences importantesMesures de sécurité additionnelles Installation du panneau de remplissageSpécifications de la fenêtre Outils nécessairesClimatiseur d’air individuel Affichage de la température et du nombre d’heures Commande principaleCommande de la minuterie Température/DuréeTélécommande de Climatiseur Dépose du panneau frontal décoratifLors de l’utilisation au mode de Symptôme Causes possibles SolutionsFonctionnement au mode de Suffisamment froidExceptions Garantie du climatiseurGarantie limitée d’un an Pour obtenir de l’aidePage Installation Guide/Guía de instalación/Guide d’installation

A6X05F2G specifications

The Fedders A6X05F2G is a powerful and efficient air conditioning unit designed to provide optimal comfort for residential and commercial spaces. With its advanced engineering and cutting-edge technology, this model stands out in the HVAC market for its impressive performance and user-friendly features.

One of the main features of the A6X05F2G is its robust cooling capacity. With a cooling power of 6,000 BTUs, this unit is capable of effectively cooling medium-sized rooms, making it an ideal choice for living rooms, bedrooms, or small offices. The energy efficiency of the unit is also notable, with a SEER (Seasonal Energy Efficiency Ratio) rating that ensures lower electricity bills while maintaining a comfortable indoor environment.

The A6X05F2G is equipped with a quiet operation system that minimizes noise levels during operation. This is particularly beneficial for users who seek a serene atmosphere in their living or working spaces. The unit’s design incorporates sound-dampening technology that allows it to function discreetly without compromising on performance.

Additionally, the air conditioner features multiple fan speeds and an adjustable thermostat, providing users with customizable settings to suit their comfort preferences. The unit also includes a programmable timer, allowing for convenient scheduling of operation, which can enhance energy savings by ensuring the system runs only when needed.

In terms of air quality, the Fedders A6X05F2G includes a built-in air filtration system that helps to remove dust, allergens, and other particles from the air, promoting a healthier indoor environment. This feature is particularly valuable for individuals with allergies or respiratory conditions.

Installation of the A6X05F2G is straightforward, thanks to its compact design and lightweight structure, which allows for easy handling and placement in various settings. The durable construction materials ensure longevity and reliability over time.

Overall, the Fedders A6X05F2G air conditioning unit is a top-tier choice for anyone looking for an effective cooling solution. With its energy efficiency, customizable features, quiet operation, and air filtration capabilities, it delivers comfort and convenience for users seeking a high-quality HVAC option.