Q-Logic ISR6142 manual Table A-10. Fibre Channel Driver-Error Log Messages

Page 89

A

A – Log Messages Error Log Messages

Table A-10. Fibre Channel Driver—Error Log Messages (Continued)

ID

Log Messages

No.

 

 

 

107254

#%d: QLUpdateSinglePortCont 0x%x: out of slots in host

758

 

database

 

 

 

 

107267

#%d: QLFcipIsrEventHandler: System error event (%x),

771

 

MB1=%x, MB2=%x, MB3=%x, MB4=%x, MB5=%x, MB6=%x,

 

 

MB7=%x

 

 

 

 

87The FC processor received a SCSI command for an unknown target path or has run out of resources to execute additional commands.

93The FC processor was disabled by an IOCTL request to the driver.

94The FC processor firmware failed initialization. The request to initialize was received by the driver in an IOCTL request.

96The FC processor failed the external loopback test.

97The FC processor failed to re-initialize in response to an IOCTL disable request.

99

Invalid Virtual Port loop ID.

307 The FC processor reported a link down condition.

317The FC processor reported an unexpected asynchronous event. The mailbox registers provide status, event code, and data related to the event.

350 FCIP Response queue entry TRB pointer is NULL.

357The driver has determined that the FC link is unreliable and unusable due to the number of errors encountered. The link has been taken down.

416The FC processor was unable to obtain the number of loop IDs required. This failure occurs only when the FC processor is running multi-ID firmware.

432The driver was unable to re-establish connection to the target within the timeout and retry counts, and is therefore marking it offline.

452The FC processor is unable to log into the FC fabric name server.

533The driver’s host (initiator) database is full.

545The driver’s target database is full.

560The driver’s host (initiator) database is full. Maximum host database is 64.

562FC processor "Get VP Database entry command" failed.

SN0051102-00 A

A-21

Image 89
Contents ISR6142 Intelligent Storage Router Document Revision History Table of Contents Planning Installation Removal/Replacement List of Figures ISR6142 Intelligent Storage Router Installation Guide Related Materials Intended AudienceSafety Communications Statements Federal Communications Commission FCC Class a Statement CE Statement Vcci Class a Statement Laser Safety InformationElectrostatic Discharge Sensitivity Esds Precautions License Agreements Accessible PartsGeneral Public License PreambleIntroduction General Public License Introduction General Public License Introduction General Public License Introduction General Public License No Warranty Copyright C yyyy name of author How to Apply These Terms to Your New ProgramsTraining Technical SupportAvailability Support Headquarters Contact InformationGeneral Description SmartWrite Licensed FeaturesRouter Capabilities Additional Server/Ports Remote SAN Island Connectivity Remote SAN Island ConnectivityLocal SAN Island Connectivity Chassis LEDs Local SAN Island ConnectivityFcip Fibre Channel over IP System Fault LED Amber Input Power LED GreenSystem Fault LED Blink Patterns Chassis ControlsReset a Router Maintenance ButtonFibre Channel Ports Enable DhcpPort LEDs Fibre Channel Port LEDsFibre Channel SFP Transceivers Ethernet Port Management ISCSI/Gigabit Ethernet Port LEDsRJ-45 to DB-9 Adapter Pin Identification Serial PortSerial Port Pin Identification DB-9F Devices PlanningFC Performance Device AccessFibre Channel ISCSIDistance ISCSI/Gigabit Ethernet PerformanceBandwidth LatencyT1 / DS-1 1.554 Mbits/Sec Performance TuningDS-5 400 Mbits/Sec T3 / DS-3 45 Mbits/SecOC-3 150 Mbits/Sec OC-1 50 Mbits/SecOC-12 and Above 621 Mbits/Sec TopologyMultiple Routers Fibre Channel Switch Ports and Zoning RequirementsManagement RecoverySecurity ServicesManagement Workstation Requirements Site RequirementsManagement Workstation Environmental Conditions ISR6142 Router InstallationPower Requirements ISR6142 Router and Accessories Mount the Router Pre-installation Check ListPre-installation Checklist Connect the Management Workstation to the Router Install the TransceiversConfigure the Management Workstation Setting the Workstation IP Address Select the Intelligent Storage Routers icon Install the SANsurfer Router ManagerStart the SANsurfer Router Manager Linux InstallationDemko Connect the Router to AC PowerTelnet 10.0.0.1 username guest password Configure the RouterCable Devices to the Router Firmware InstallationUsing the SANsurfer Router Manager to Install Firmware Type set to Using the CLI to Install FirmwareImage unpack isr-6142-220x.bin Installation Firmware Installation SN0051102-00 a Chassis Diagnostics Diagnostics TroubleshootingSystem Fault LED is On Power-On Self-Test DiagnosticsInput Power LED is Off Heartbeat Blink Pattern System Error Blink PatternLED Blink Patterns Management Port IP Address Conflict Blink Pattern Over-Temperature Blink PatternRecovering a Router Page SFP Transceiver Removal and Replacement Removal/ReplacementRemoval Router Removal and ReplacementReplacement Informational Log Messages Log DataTable A-1. Application Modules-Informational Log Messages Application ModulesTable A-1. Application Modules-Informational Log Messages Table A-2. iSCSI Driver-Informational Log Messages ISCSI DriverTable A-3. Fibre Channel Driver-Informational Log Messages Fibre Channel DriverTable A-4. User Modules-Informational Log Messages User ModulesTable A-4. User Modules-Informational Log Messages Table A-5. FCIP-Informational Log Messages FcipSystem TOE DriverTable A-6. TOE-Informational Log Messages Table A-7. System-Informational Log MessagesTable A-8. Application Module-Error Log Messages Error Log MessagesCapacity Table A-8. Application Module-Error Log Messages Table A-8. Application Module-Error Log Messages Page Log Messages Error Log Messages Page Page Table A-9. iSCSI Driver-Error Log Messages Page Log Messages Table A-10. Fibre Channel Driver-Error Log MessagesTable A-10. Fibre Channel Driver-Error Log Messages Table A-11. User Modules-Error Log Messages Table A-11. User Modules-Error Log Messages Page Table A-13. iSCSI Driver-Fatal Log Messages Table A-12. System-Error Log MessagesFatal Log Messages Etpassthroughstatus Table A-13. iSCSI Driver-Fatal Log Messages Table A-14. Fibre Channel Driver-Fatal Log Messages FC DriverTable A-14. Fibre Channel Driver-Fatal Log Messages Table A-15. TOE-Fatal Log Messages Table A-16. System-Fatal Log Messages Log Messages Fatal Log Messages SN0051102-00 a Table B-1. Snmp Properties IntroductionSnmp Properties Table B-2. Snmp Trap Configuration Parameters Snmp Trap ConfigurationSystem Information Management Information Base MIBQsrNwPortEntry Network Port TableQsrNwPortIndex QsrNwPortRoleQsrNwPortAddressMode QsrIPAddressTypeFibre Channel Port Table QsrFcPortRole QsrFcPortEntryQsrFcPortIndex QsrFcPortNodeWwnSensor Table QsrSensorType QsrSensorEntryQsrSensorIndex QsrSensorUnitsQsrUpperThreshold QsrSensorValueQsrLowerThreshold QsrSensorStateNotification Objects NotificationsQsrEventSeverity QsrEventDescriptionAgent Shut Down Notification Agent Start Up NotificationNetwork Port Down Notification Fibre Channel Port Down NotificationGeneric Notification Sensor NotificationPage Index Index-2 SN0051102-00 a Fcip A-8 MIB MIB B-3
Related manuals
Manual 154 pages 40.65 Kb

ISR6142 specifications

The Q-Logic ISR6142 is a state-of-the-art intelligent storage router that plays a crucial role in modern data centers. This high-performance solution has been specifically designed to address the growing demands of cloud computing, big data, and virtualization environments. With its innovative features and technologies, the ISR6142 significantly enhances data management and accessibility while ensuring high throughput and low latency.

One of the standout features of the ISR6142 is its ability to support advanced storage protocols. It seamlessly integrates with various networking protocols like Fibre Channel, iSCSI, and NFS, allowing for versatile connectivity options. This flexibility ensures compatibility with existing storage and network infrastructures, making it an ideal solution for businesses looking to optimize their storage efficiency without overhauling their entire system.

The ISR6142 is powered by cutting-edge data management technologies, including data deduplication and compression. These capabilities help organizations greatly reduce storage space requirements and improve overall efficiency by eliminating duplicate data and minimizing file sizes. This not only saves costs associated with storage but also enhances data transfer rates, enabling faster operations and improved performance.

Scalability is another key characteristic of the ISR6142. It can easily accommodate the growing data needs of organizations by expanding storage capacities and supporting multiple array types. This adaptability allows businesses to scale their storage solutions without major disruptions, ensuring continuous operations even as data volumes increase.

Security is a top priority for any data storage solution, and the ISR6142 excels in this area as well. It incorporates robust security features such as end-to-end encryption and multi-factor authentication, safeguarding sensitive data from unauthorized access and potential breaches. This level of protection is vital for companies that handle critical information and need to comply with various regulatory requirements.

Additionally, the ISR6142 offers comprehensive management tools that provide real-time monitoring and analytics. These tools allow administrators to gain insights into storage performance and health, enabling proactive management and maintenance. The user-friendly interface simplifies operations, making it easier for IT teams to monitor and troubleshoot.

In summary, the Q-Logic ISR6142 storage router is a powerful and versatile solution tailored to meet the demands of contemporary data management. With its advanced protocol support, data efficiency technologies, scalability, robust security measures, and comprehensive management capabilities, the ISR6142 is well-equipped to help organizations tackle the challenges of today’s data-driven landscape. Investing in this intelligent storage router means guaranteeing a more efficient, secure, and scalable storage architecture for any enterprise.