Q-Logic ISR6142 manual

Page 92

A – Log Messages Error Log Messages

S

21Failed memory allocation for Get LUN List API.

22Failed memory allocation for Get Presented Targets List API.

23Failed memory allocation for Get LUN Mask API.

24Failed memory allocation for Initiator API.

25Failed memory allocation for Target Device API.

32Failed memory allocation for FC Target API.

33Failed memory allocation for System Status API.

34Failed memory allocation for Diagnostic API.

35Failed memory allocation for Diagnostic Log API.

36Failed memory allocation for FRU Image API.

37Failed memory allocation for OEM Manufacturing API.

38Failed memory allocation for Status API.

39Failed memory allocation for TCP/IP Statistics API.

40Failed memory allocation for NTP Status API.

41Failed memory allocation for LUN List API.

51

RPC free resources entry point.

 

 

289

Detected duplicate IP address for management port.

 

 

A-24

SN0051102-00 A

Image 92
Contents ISR6142 Intelligent Storage Router Document Revision History Table of Contents Planning Installation Removal/Replacement List of Figures ISR6142 Intelligent Storage Router Installation Guide Intended Audience Related MaterialsSafety Communications Statements Federal Communications Commission FCC Class a Statement CE Statement Vcci Class a Statement Laser Safety InformationElectrostatic Discharge Sensitivity Esds Precautions Accessible Parts License AgreementsGeneral Public License PreambleIntroduction General Public License Introduction General Public License Introduction General Public License Introduction General Public License No Warranty How to Apply These Terms to Your New Programs Copyright C yyyy name of authorTraining Technical SupportAvailability Contact Information Support HeadquartersGeneral Description SmartWrite Licensed FeaturesRouter Capabilities Additional Server/Ports Remote SAN Island Connectivity Remote SAN Island ConnectivityLocal SAN Island Connectivity Chassis LEDs Local SAN Island ConnectivityFcip Fibre Channel over IP Input Power LED Green System Fault LED AmberSystem Fault LED Blink Patterns Chassis ControlsMaintenance Button Reset a RouterEnable Dhcp Fibre Channel PortsFibre Channel Port LEDs Port LEDsFibre Channel SFP Transceivers ISCSI/Gigabit Ethernet Port LEDs Ethernet Port ManagementRJ-45 to DB-9 Adapter Pin Identification Serial PortSerial Port Pin Identification DB-9F Planning DevicesDevice Access FC PerformanceFibre Channel ISCSIISCSI/Gigabit Ethernet Performance DistanceBandwidth LatencyPerformance Tuning T1 / DS-1 1.554 Mbits/SecT3 / DS-3 45 Mbits/Sec DS-5 400 Mbits/SecOC-1 50 Mbits/Sec OC-3 150 Mbits/SecTopology OC-12 and Above 621 Mbits/SecFibre Channel Switch Ports and Zoning Requirements Multiple RoutersRecovery ManagementServices SecurityManagement Workstation Requirements Site RequirementsManagement Workstation Environmental Conditions ISR6142 Router InstallationPower Requirements ISR6142 Router and Accessories Mount the Router Pre-installation Check ListPre-installation Checklist Connect the Management Workstation to the Router Install the TransceiversConfigure the Management Workstation Setting the Workstation IP Address Install the SANsurfer Router Manager Select the Intelligent Storage Routers iconLinux Installation Start the SANsurfer Router ManagerConnect the Router to AC Power DemkoConfigure the Router Telnet 10.0.0.1 username guest passwordCable Devices to the Router Firmware InstallationUsing the SANsurfer Router Manager to Install Firmware Using the CLI to Install Firmware Type set toImage unpack isr-6142-220x.bin Installation Firmware Installation SN0051102-00 a Diagnostics Troubleshooting Chassis DiagnosticsSystem Fault LED is On Power-On Self-Test DiagnosticsInput Power LED is Off Heartbeat Blink Pattern System Error Blink PatternLED Blink Patterns Over-Temperature Blink Pattern Management Port IP Address Conflict Blink PatternRecovering a Router Page Removal/Replacement SFP Transceiver Removal and ReplacementRemoval Router Removal and ReplacementReplacement Log Data Informational Log MessagesApplication Modules Table A-1. Application Modules-Informational Log MessagesTable A-1. Application Modules-Informational Log Messages ISCSI Driver Table A-2. iSCSI Driver-Informational Log MessagesFibre Channel Driver Table A-3. Fibre Channel Driver-Informational Log MessagesUser Modules Table A-4. User Modules-Informational Log MessagesTable A-4. User Modules-Informational Log Messages Fcip Table A-5. FCIP-Informational Log MessagesTOE Driver SystemTable A-6. TOE-Informational Log Messages Table A-7. System-Informational Log MessagesError Log Messages Table A-8. Application Module-Error Log MessagesCapacity Table A-8. Application Module-Error Log Messages Table A-8. Application Module-Error Log Messages Page Log Messages Error Log Messages Page Page Table A-9. iSCSI Driver-Error Log Messages Page Table A-10. Fibre Channel Driver-Error Log Messages Log MessagesTable A-10. Fibre Channel Driver-Error Log Messages Table A-11. User Modules-Error Log Messages Table A-11. User Modules-Error Log Messages Page Table A-13. iSCSI Driver-Fatal Log Messages Table A-12. System-Error Log MessagesFatal Log Messages Etpassthroughstatus Table A-13. iSCSI Driver-Fatal Log Messages FC Driver Table A-14. Fibre Channel Driver-Fatal Log MessagesTable A-14. Fibre Channel Driver-Fatal Log Messages Table A-15. TOE-Fatal Log Messages Table A-16. System-Fatal Log Messages Log Messages Fatal Log Messages SN0051102-00 a Table B-1. Snmp Properties IntroductionSnmp Properties Snmp Trap Configuration Table B-2. Snmp Trap Configuration ParametersManagement Information Base MIB System InformationNetwork Port Table QsrNwPortEntryQsrNwPortRole QsrNwPortIndexQsrNwPortAddressMode QsrIPAddressTypeFibre Channel Port Table QsrFcPortEntry QsrFcPortRoleQsrFcPortIndex QsrFcPortNodeWwnSensor Table QsrSensorEntry QsrSensorTypeQsrSensorIndex QsrSensorUnitsQsrSensorValue QsrUpperThresholdQsrLowerThreshold QsrSensorStateNotifications Notification ObjectsQsrEventSeverity QsrEventDescriptionAgent Start Up Notification Agent Shut Down NotificationNetwork Port Down Notification Fibre Channel Port Down NotificationSensor Notification Generic NotificationPage Index Index-2 SN0051102-00 a Fcip A-8 MIB MIB B-3
Related manuals
Manual 154 pages 40.65 Kb

ISR6142 specifications

The Q-Logic ISR6142 is a state-of-the-art intelligent storage router that plays a crucial role in modern data centers. This high-performance solution has been specifically designed to address the growing demands of cloud computing, big data, and virtualization environments. With its innovative features and technologies, the ISR6142 significantly enhances data management and accessibility while ensuring high throughput and low latency.

One of the standout features of the ISR6142 is its ability to support advanced storage protocols. It seamlessly integrates with various networking protocols like Fibre Channel, iSCSI, and NFS, allowing for versatile connectivity options. This flexibility ensures compatibility with existing storage and network infrastructures, making it an ideal solution for businesses looking to optimize their storage efficiency without overhauling their entire system.

The ISR6142 is powered by cutting-edge data management technologies, including data deduplication and compression. These capabilities help organizations greatly reduce storage space requirements and improve overall efficiency by eliminating duplicate data and minimizing file sizes. This not only saves costs associated with storage but also enhances data transfer rates, enabling faster operations and improved performance.

Scalability is another key characteristic of the ISR6142. It can easily accommodate the growing data needs of organizations by expanding storage capacities and supporting multiple array types. This adaptability allows businesses to scale their storage solutions without major disruptions, ensuring continuous operations even as data volumes increase.

Security is a top priority for any data storage solution, and the ISR6142 excels in this area as well. It incorporates robust security features such as end-to-end encryption and multi-factor authentication, safeguarding sensitive data from unauthorized access and potential breaches. This level of protection is vital for companies that handle critical information and need to comply with various regulatory requirements.

Additionally, the ISR6142 offers comprehensive management tools that provide real-time monitoring and analytics. These tools allow administrators to gain insights into storage performance and health, enabling proactive management and maintenance. The user-friendly interface simplifies operations, making it easier for IT teams to monitor and troubleshoot.

In summary, the Q-Logic ISR6142 storage router is a powerful and versatile solution tailored to meet the demands of contemporary data management. With its advanced protocol support, data efficiency technologies, scalability, robust security measures, and comprehensive management capabilities, the ISR6142 is well-equipped to help organizations tackle the challenges of today’s data-driven landscape. Investing in this intelligent storage router means guaranteeing a more efficient, secure, and scalable storage architecture for any enterprise.