PicoScope 6 User Guide

6.5.2.4.1 Lookup-table Scaling dialog

This dialog allows you to enter a look-up table to calibrate a custom probe. You can

get here by clicking the Create a Look-up Table button or Edit the Lookup Table...

button in the Scaling Method dialog 32.

Editing the Look-up Table

First, select suitable values in the Input units and Scaled units drop-down boxes. For example, if your probe is a current clamp that outputs one millivolt per ampere over the range -600 to +600 amperes, select Input units of millivolts and Output units of amperes.

Next, enter some data in the scaling table. Click the first empty cell at the top of the table and type "-600", then hit the Tab key and type "-600". When you are ready to enter the next pair of values, press the Tab key again to start a new row. You can also right-click on the table to obtain a more detailed menu of options, as shown in the picture. In the example above, we have entered a slightly nonlinear response; if the response had been linear then it would have been easier to use the linear option in the Scaling Method Dialog 32.

Import/Export

Using the Import and Export buttons, you can fill the look-up table from data in a comma-separated or tab-delimited text file, and save the look-up table to new file.

Finishing

Clicking OK or Cancel will return you to the Scaling Method dialog

32.

PSW044-2.0

Copyright 2006 Pico Technology Limited. All rights reserved.

Image 36
Contents PicoScope PC Oscilloscope Software Table of Contents How to ReferenceIndex How to use this manual Whats new in this version? WelcomeVersion 6.0 update Version 6.0 updateNew features Higher performanceHow to use PicoScope IntroductionLegal statement How to use this manual Contact informationSystem requirements Using PicoScope for the first time Using PicoScope for the first timeIt didnt do what I expected PicoScope and oscilloscope primer Oscilloscope basicsPCO basics PicoScope basicsPicoScope and oscilloscope primer Capture window To open a new capture windowTo arrange the scope views within the capture window Custom probes Frequency legendMeasurements table To edit a measurementTo change the width of a measurement column Procedure How to choose the oversampling factorOversampling Post-trigger arrow Ruler legendScope view Cursor position tool tipTime rulers Ruler tool tipTrigger marker Signal rulers Ruler tooltipWindows, views and viewports Upgrading from PicoScopeMenus File menu MenusSettings files *.pssettings Save As dialogData files *.psdata Menus Text Tab delimited *.txt Bitmap Image *.bmpGIF Image *.gif PNG Image *.pngEdit menu Help menu Measurements menu Add / Edit Measurement dialog Tools menu Custom Probes dialogCustom Probe wizard Adding a new probe to your libraryHow to use the dialog Create New Custom Probe dialogEdit Existing Custom Probe dialog Probe Output Units dialog Scaling Method dialog Editing the Look-up Table Import/ExportFinishing What is Auto-ranging? Range Management dialogManual Ranges Setup dialog How to use a new custom rangeAutomatic mode Fixed range modeWhat is an input range? What is a scaled range?PicoScope 6 User Guide Range utilisation bar Custom Probe Identification dialog Custom Probe Finished dialog Where to find it Preferences dialogGeneral dialog Performance dialog How to use it Toolbar menuWindow menu Toolbars ToolbarsCustomizing Buffer Navigation toolbar Capture Windows toolbarWaveform buffer Demo mode Open Device dialogChannel Setup toolbar Probe Drop-Down menuCustomization dialog Customization Toolbars Customization Commands Customization Options Options tab of the Customization dialog ToolbarsHelp toolbar Measurements toolbarMeasurements toolbar controls the measurements table Add MeasurementScope Setup toolbar Standard controlsAdditional controls Signal Generator toolbar Signal Generator dialogLeft Signal generator dialog for the PicoScope 3206 PicoScope 6 User Guide How to use it Start / Stop toolbar Trigger Mode Triggering toolbarTechnical Note Zooming and Scrolling toolbar Demo Signals toolbar Demo Signals dialogHow to How toHow to change to a different scope device How to use rulers to measure a signalUsing a single ruler for signal-to-ground measurements Using two rulers for differential measurementsHow to measure a time difference How to move a viewReference Measurement typesReference Peak To Peak The difference between maximum and minimumTrigger timing part Tip Keyboard shortcuts Glossary Index Index PicoScope 6 User Guide PSW044-2.0

PSW044-2.0 specifications

The Pico Macom PSW044-2.0 is a versatile and efficient satellite signal splitter designed for seamless distribution of satellite signals in residential and commercial settings. This innovative device stands out for its exceptional performance, solid build quality, and user-friendly features, making it a reliable choice for installers and system integrators.

One of the main features of the PSW044-2.0 is its four-way signal distribution capability, allowing users to connect multiple devices such as satellite receivers, DVRs, or televisions to a single satellite dish. This is particularly beneficial in multi-room setups where each room may require access to satellite signal without the need for multiple dishes. The splitter effectively reduces the clutter of additional cables while maintaining signal integrity.

The PSW044-2.0 is built on advanced technologies that ensure minimal signal loss and high-frequency stability. Featuring a wide frequency range from 5 MHz to 2300 MHz, this splitter is compatible with a broad range of satellite frequencies, including both standard and high-definition signals. This makes it an ideal choice for modern homes equipped with advanced satellite systems.

Another characteristic that sets the Pico Macom PSW044-2.0 apart is its robust construction. The device is engineered with high-quality materials to enhance durability and longevity. Its compact design makes it easy to install in tight spaces, while the LED indicators facilitate monitoring of signal transmission.

For enhanced performance, the PSW044-2.0 incorporates advanced isolation techniques that prevent signal interference between outputs. This ensures that connected devices can operate without cross-talk, which is crucial for clear and uninterrupted viewing experiences. Additionally, the splitter is designed to handle varying line voltages and has built-in surge protection to safeguard connected equipment from electrical surges.

Overall, the Pico Macom PSW044-2.0 is a sophisticated solution for anyone needing to distribute satellite signals efficiently and effectively. With its combination of high performance, durability, and user-friendly features, it significantly enhances the satellite signal distribution experience, making it a valuable component in any satellite communication setup.