Pico Macom PSW044-2.0 manual PicoScope 6 User Guide How to use it, Where to find it

Page 58

55

PicoScope 6 User Guide

How to use it

Signal On: Tick this box to enable the signal generator.

Frequency: Type in this box or use the spin buttons to select the frequency. If the scope device has a frequency sweep generator, then this box will set the start frequency of the sweep.

Sweep Mode Active. Tick this box to enable sweep mode. Otherwise, the generator will operate at a fixed frequency set by the Start Frequency box.

Repeat Signal. Tick this box to generate a repetitive sweep. Otherwise, the generator will reach Stop Frequency and then remain there.

Dual Slope. In normal mode, the generator will increase the frequency linearly from Start Frequency to Stop Frequency, and then immediately begin again at Start Frequency. In Dual Slope mode, it will reach Stop Frequency and then decrease the frequency linearly to Start Frequency before beginning again.

Stop Frequency. In Sweep Mode, the generator will stop increasing the frequency when it reaches Stop Frequency.

Frequency Increment. In Sweep Mode, the generator will increase or decrease the frequency by this amount every Increment Time Interval.

Increment Time Interval. In Sweep Mode, the generator will increase or decrease the frequency by Frequency Increment once every time interval of this duration.

Where to find it

Click the menu button on the Signal Generator toolbar

54.

PSW044-2.0

Copyright 2006 Pico Technology Limited. All rights reserved.

Image 58
Contents PicoScope PC Oscilloscope Software Table of Contents Reference How toIndex How to use this manual Whats new in this version? WelcomeNew features Version 6.0 updateVersion 6.0 update Higher performanceHow to use PicoScope IntroductionLegal statement Contact information How to use this manualSystem requirements Using PicoScope for the first time Using PicoScope for the first timeIt didnt do what I expected PicoScope and oscilloscope primer Oscilloscope basicsPicoScope basics PCO basicsPicoScope and oscilloscope primer To open a new capture window Capture windowTo arrange the scope views within the capture window Custom probes Frequency legendTo edit a measurement Measurements tableTo change the width of a measurement column How to choose the oversampling factor ProcedureOversampling Post-trigger arrow Ruler legendScope view Cursor position tool tipTime rulers Ruler tool tipTrigger marker Signal rulers Ruler tooltipWindows, views and viewports Upgrading from PicoScopeMenus File menu MenusSave As dialog Settings files *.pssettingsData files *.psdata GIF Image *.gif Menus Text Tab delimited *.txtBitmap Image *.bmp PNG Image *.pngEdit menu Help menu Measurements menu Add / Edit Measurement dialog Tools menu Custom Probes dialogCustom Probe wizard Adding a new probe to your libraryHow to use the dialog Create New Custom Probe dialogEdit Existing Custom Probe dialog Probe Output Units dialog Scaling Method dialog Import/Export Editing the Look-up TableFinishing What is Auto-ranging? Range Management dialogManual Ranges Setup dialog How to use a new custom rangeWhat is an input range? Automatic modeFixed range mode What is a scaled range?PicoScope 6 User Guide Range utilisation bar Custom Probe Identification dialog Custom Probe Finished dialog Preferences dialog Where to find itGeneral dialog Performance dialog How to use it Toolbar menuWindow menu Toolbars ToolbarsCustomizing Capture Windows toolbar Buffer Navigation toolbarWaveform buffer Demo mode Open Device dialogChannel Setup toolbar Probe Drop-Down menuCustomization dialog Customization Toolbars Customization Commands Customization Options Options tab of the Customization dialog ToolbarsMeasurements toolbar controls the measurements table Help toolbarMeasurements toolbar Add MeasurementStandard controls Scope Setup toolbarAdditional controls Signal Generator dialog Signal Generator toolbarLeft Signal generator dialog for the PicoScope 3206 PicoScope 6 User Guide How to use it Start / Stop toolbar Triggering toolbar Trigger ModeTechnical Note Zooming and Scrolling toolbar Demo Signals toolbar Demo Signals dialogHow to How toUsing a single ruler for signal-to-ground measurements How to change to a different scope deviceHow to use rulers to measure a signal Using two rulers for differential measurementsHow to measure a time difference How to move a viewReference Measurement typesReference Peak To Peak The difference between maximum and minimumTrigger timing part Tip Keyboard shortcuts Glossary Index Index PicoScope 6 User Guide PSW044-2.0

PSW044-2.0 specifications

The Pico Macom PSW044-2.0 is a versatile and efficient satellite signal splitter designed for seamless distribution of satellite signals in residential and commercial settings. This innovative device stands out for its exceptional performance, solid build quality, and user-friendly features, making it a reliable choice for installers and system integrators.

One of the main features of the PSW044-2.0 is its four-way signal distribution capability, allowing users to connect multiple devices such as satellite receivers, DVRs, or televisions to a single satellite dish. This is particularly beneficial in multi-room setups where each room may require access to satellite signal without the need for multiple dishes. The splitter effectively reduces the clutter of additional cables while maintaining signal integrity.

The PSW044-2.0 is built on advanced technologies that ensure minimal signal loss and high-frequency stability. Featuring a wide frequency range from 5 MHz to 2300 MHz, this splitter is compatible with a broad range of satellite frequencies, including both standard and high-definition signals. This makes it an ideal choice for modern homes equipped with advanced satellite systems.

Another characteristic that sets the Pico Macom PSW044-2.0 apart is its robust construction. The device is engineered with high-quality materials to enhance durability and longevity. Its compact design makes it easy to install in tight spaces, while the LED indicators facilitate monitoring of signal transmission.

For enhanced performance, the PSW044-2.0 incorporates advanced isolation techniques that prevent signal interference between outputs. This ensures that connected devices can operate without cross-talk, which is crucial for clear and uninterrupted viewing experiences. Additionally, the splitter is designed to handle varying line voltages and has built-in surge protection to safeguard connected equipment from electrical surges.

Overall, the Pico Macom PSW044-2.0 is a sophisticated solution for anyone needing to distribute satellite signals efficiently and effectively. With its combination of high performance, durability, and user-friendly features, it significantly enhances the satellite signal distribution experience, making it a valuable component in any satellite communication setup.