MartinLogan MAC 500/E user manual Specification s

Page 34

S p e c i f i c a t i o n s

M e a s u r e m e n t s

Length

356 mm (14.0 in)

Width

481 mm (18.9 in)

Height (head at tilt limit)

673 mm (26.5 in)

Weight, MAC 500

32.8 kg (72.1 lbs)

Weight, MAC 500 E

26.1 kg (57.4 lbs)

E l e c t r i c a l , M A C 5 0 0

Ballast taps

200/230/245V @ 50 Hz;

208/ 227V @ 60 Hz

Power and current*

750 W, 3.4 A @ 230 V / 50 Hz; 750 W, 4.3

A @ 208 V / 60 Hz

Power factor (PF)*

0.85

E l e c t r i c a l , M A C 5 0 0 E

Transformer taps

100/110/120/200/210/220/230/240 @ 50 - 60

Hz

Power and current*

690 W, 3.2 A @ 230 V / 50

Hz

Power factor (PF)*

................................. 0.94

F u s e s

Main fuse, MAC 500, MAC 500 E wired between 200 - 240 V

............. time-delay 6.3 A / 250 V, P/N 05020020

Main fuse, MAC 500 E wired between 100 - 120 V

time-delay 10.0 A / 250 V, P/N 05020025

Fuse F601

time-delay 5.0 A / 25 0

V, P/N 05020018

Fuse F602

time-delay 4.0

A / 25 0

V, P/N 05020016

Fuse F603

time-delay 0.315

A / 250 V, P/N 05020004

C o m m u n i c a t i o n

Hardware standard

........................... RS-485

Protocols

USITT DMX512 (1990) / Martin RS-485

DMX start code

....................................... 0

Recommended cable

24 AWG (min.), low capacitance, 85-150 Ω shielded twisted pair

Connector type

3-pin XLR male/female (pin 1 = screen, pins 2 and 3 configurable +/-)

C o m p a t i b l e l a m p s

Osram HSR-575/2

575

W, 85 lm/W, 1000 h avg. life, 6000K,

P/N 97010200

Osram HSD-575

575

W, 78 lm/W, 3000 h avg. life, 7200K,

P/N 9701020 7

Philips MSD-575

575

W, 75 lm/W, 2000 h avg. life, 5700K,

P/N 97010202

Philips MSR-575/2

575 W, 85 lm/W, 1000 h avg. life, 6100K,

P/N 9701020 1

P h o t o m e t r i c

Center intensity w/ standard 17° lens set

246,000 cd

Center intensity w/ optional 23.5° lens set

134,000 cd

Total integrated luminous flux (with standard lens, MSR 575/2)

9000 lm

T h e r m a l

Maximum ambient temperature

40° C (104° F)

Maximum surface temperature under normal operating conditions

80° C (176° F)

34

MAC 500/E User Manual

Image 34
Contents MAC 500/E Page Introduction C 5 0 0 / E s a f e t y i n f o r m a t i o n T R O D U C T I O NC t i o n T U P Install i n g o r c h a n g i n g t h e l a m pP a c k i n g W e r i n g t h e f i x t u r e Install a p l u g o n t h e p o w e r c o r dWire Pin Marking Screw US G g i n gP s f o r b u i l d i n g a s e r i a l l i n k N n e c t i n g t h e s e r i a l l i n kN n e c t i n g f i x t u r e s Page X 5 1 2 c o n t r o l E R a T I O NR t i n R S 4 8 5 c o n t r o l Tr a c k i n g c o n t r o lN t r o l l a b l e e f f e c t s T a t i n g p r i s m / v a r i a b l e f r o s t T a t i n g g o b o sI s M m e r / s h u t t e rN T R O L P a N E L N u n a v i g a t i o nR s o n a l i t y s e t t i n g s D r e s s a n d p r o t o c o l s e l e c t i o n A d o u t sN u a l c o n t r o l A n d a l o n e s e q u e n c e sL i b r a t i o n C a L S e t d e Fault o f f s e t s SPEC/dFOFI l i t i e s L o a d m o d e UPLdB o o r i e n t a t i o n a n d p o s i t i o n s B o Specification sB O S a N D C O L O R F I L T E R S A s s g o b o sT a l a n d i m a g e g o b o s Fault g o b o l a y o u tO s e r o t a t i n g g o b o f i T h o u t t o o l s A n g i n g r o t a t i n g g o b o sA n g i n g s t a t i c g o b o s T h n e e d l e n o s e p l i e r sFault c o l o r f i l t e r p o s i t i o n s A n g i n g c o l o r f i l t e r sM o v i n g t h e p r i n t e d c i r c u i t b o a r d I N T E N a N C E a N D B a S I C S E R V I C EC e s s i n g p a r t s E n i n g t h e h e a dA n g i n g t h e X L R p i n o u t P l a c i n g f u s e sC 5 0 0 w i t h m a g n e t i c b a l l a s t R m a l u p l o a d C 5 0 0 E w i t h e l e c t r o n i c b a l l a s tO t m o d e u p l o a d A n g i n g l e n s e s P l a c i n g t h e l a m pT i m i z i n g l a m p a l i g n m e n t I n t e n a n c e s c h e d u l eT i c a l c o m p o n e n t s E a n i n gB r i c a t i o n N sDMX Channel Start code = P E N D I C E SX p r o t o c o l Percent FunctionAlternate Functions Enable on channel Value Percent FunctionFixed Gobos Value Combined Rotating Prism and Gobo MacrosS s a g e s Display readout Appears if What to doProblem Probable causes Remedy Tr o u b l e s h o o t i n gR c u i t b o a r d l a y o u t Specification s C e s s o r i e s MAC 500 DMX Protocol