Strong Enterprises 48057 manual Xenon Trouper Troubleshooting, Bulb fails to ignite

Page 21

XENON TROUPER TROUBLESHOOTING

Bulb fails to ignite.

1.MODE switch S3 set to “AUTO.” Place in “MAN.” position when not employing automated or remote lamphouse operation.

2.AC power not on to lamphouse. Turn switching power supply 30 A. circuit breaker ON. If 115 V.AC not read at 2 & 4, see power supply manual.

3.Top cover or side access panel interlock switch (S1, S5) open. Close and secure lamphouse top cover. Tighten all four mounting screws; check switch actuating screw. Tighten side access panel screws.

4.Faulty interlock switch(s). Check for 115 V.AC at 9 & 12; replace switch(s) if defective.

5.Faulty S2 “ON-OFF” switch. Check for voltage at 3 & 5; check for loose terminals or wiring. Replace if defective.

Bulb fails to ignite; ping audible, bulb flash visible.

1.Inadequate DC output from xenon power supply. Set power supply output to correct range required for bulb wattage (65 A. for 1.6 kW, 75 A. for 2 kW).

2.If bulb flash is visible but faint, check for defective glass capacitor 65216 in igniter (capacitor body cracked or leaking oil). Replace if defective.

3.Faulty or expired xenon bulb. Replace as required.

Bulb fails to ignite; ping audible, no bulb flash.

1.Faulty xenon bulb. Check for cracked electrodes or darkened envelope. Replace if defective.

2.Ignition pulse shorting to ground. Inspect DC leads for burned insulation; dress leads away from grounded metal components.

No high voltage ping audible; MODE switch in “MAN.” and LAMP switch in “ON.”

1.Loss of AC control voltage. Check xenon power supply for tripped circuit breaker or open thermal switch. See power supply manual.

2.Little or no DC “No Load” voltage. Measure DC “No Load” voltage at 10 & 15. See power supply manual.

3.Open fuse F1 (600 V.) on switching power supply. SEE POWER SUPPLY MANUAL. Allow (20) minutes for capacitor discharge before replacing.

4.Faulty igniter. Check for adequate DC “No Load” at 10 & 15. If present, and igniter does not fire, replace igniter.

Bulb goes out during operation.

1.Xenon power supply overheated; thermal switch open. Check power supply blower(s), air inlets and outlets unobstructed. See power supply manual.

Image 21
Contents Xenon Trouper Page Preface Lamphouse Power Supply Installation & SET-UP Read Carefully Before Installing Xenon Bulb Safety ProceduresPage Watt Xenon Bulb Installation Page Operation Page REMOTE/AUTO Operation Handling the SpotlightExhaust System Installation Operation of Optical System Operation of Color Boomerang Maintenance Lamphouse Wiring Diagram Xenon Trouper DS1 Parts ListNormal Operation Trouble ChartPage Bulb fails to ignite Xenon Trouper TroubleshootingPower supply does not energize when actuated Color gels burning or fading prematurely Page Not Shown Page Elapsed Time Meter, 50 Hz. Export Page Parts List Items 20 & 21 shown offset for clarity. See , Items Friction Brake Screw, 1/4-20 x 1 Hex Head Nylon 48891 Page See a for current configuration Bracket, Chopper Control Handle 41-51530 Shoulder Bolt 48402 Iris Control Handle Boomerang Assembly Boomerang Parts List Folding Base & Stand Assemblies Page

48057 specifications

Strong Enterprises 48057 is a cutting-edge organization that integrates state-of-the-art technologies and innovative practices to deliver exceptional solutions across various industries. With a focus on enhancing productivity and efficiency, Strong Enterprises offers a diverse range of products and services designed to meet the evolving needs of its clients.

One of the main features of Strong Enterprises is its commitment to research and development. This dedication allows the organization to stay ahead of industry trends and harness the latest technological advancements. The company invests significantly in exploring emerging technologies such as artificial intelligence, machine learning, and the Internet of Things (IoT), enabling it to provide smart solutions that optimize operations and streamline processes.

Strong Enterprises is renowned for its robust software development capabilities. The company offers custom software solutions that are tailored to the specific requirements of its clients. By employing agile methodologies, Strong Enterprises ensures that projects are delivered on time and within budget while maintaining flexibility to adapt to changing client needs. The company’s development team is proficient in various programming languages and frameworks, allowing them to create scalable and secure applications.

In addition to software development, Strong Enterprises provides comprehensive consulting services. The organization’s team of experts works closely with clients to assess their operational needs and identify areas for improvement. By leveraging data analytics and strategic planning, Strong Enterprises helps businesses implement effective solutions that drive growth and enhance decision-making processes.

Strong Enterprises also emphasizes sustainability and environmental responsibility in its operations. The company actively seeks out eco-friendly practices and solutions, ensuring that its technologies contribute to a more sustainable future. This commitment not only aligns with global efforts to combat climate change but also resonates with clients who value environmental stewardship.

Collaboration and communication are integral to Strong Enterprises’ operational philosophy. The organization fosters a culture of teamwork, encouraging cross-functional collaboration among its employees. This not only enhances innovation but also ensures that clients receive well-rounded solutions that address all aspects of their challenges.

In conclusion, Strong Enterprises 48057 stands out as a leader in technological innovation and service excellence. With its focus on research and development, custom software solutions, consulting services, sustainability, and collaboration, Strong Enterprises is well-equipped to meet the dynamic demands of its clients and drive success in the ever-evolving business landscape.