Checking and Replacing the V-Belt and Clutch
1.After 200 hours of operation, remove the belt cover to check the
Figure 30. V-Belt Check
Replacing the V-belt
Remove the belt cover. Engage an offset wrench 3/4”(19 mm) or the like to vibrator pulley (lower) fastening bolt. Engage waste cloth or the like at midway of
Reinstalling the V-belt
Engage
Checking Clutch
Check the clutch simultaneously with
Replacing Clutch
Remove
CAUTION
Wheneverthecompactor'svibrationbecomesweakorlostduring
MVH-406GH—MAINTENANCE
Vibrator Oil Level Check
CAUTION
Always clean the area around the vibrator oil level check plug before removing oil check plug.This will prevent dirt and debris from entering the system.
1.In every 100 hours of operation, with the machine positioned horizontally, use a 3/4” (19 mm) wrench and remove vibrator oil level check plug (Figure 31).Visually inspect and see if vibrator oil level is up to filler port. Use engine oil
Figure 31. Vibrator Oil Drain and Check Plugs
DrainingVibrator Oil
1.Replace vibrator oil after first 200 hours and in every 1,000 hours of operation.
2.Position handle bar vertically (storage position).
3.Using a 14 mm wrench remove the vibrator oil drain plug (Figure 31) from the vibrating plate assembly.
For draining oil through level check hole, have the machine inclined with a sleeper or the like placed under the compaction plate on opposite side.
4.After hydraulic oil has been completely drained from machine, fill with
5.Reinstall drain plug into vibrating plate assembly.Apply seal tape or Loctite #575 to thread portion of drain plug.
Draining Hydraulic Oil
1.Disconnect the hydraulic hose (Figure 32) connected to the hydraulic oil cylinder.
MVH406GH PLATE COMPACTOR — OPERATION AND PARTS MANUAL — REV. #3 (02/04/14) — PAGE 23