Powermatic 60B operating instructions Troubleshooting Mechanical and Electrical Problems

Page 25

Troubleshooting – Mechanical and Electrical Problems

Trouble

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Probable Cause

Remedy

 

 

 

Verify unit is connected to power, on-

No incoming power.

button is pushed in completely, and

 

stop-button is disengaged.

 

 

 

When jointer overloads on the circuit

 

breaker built into the motor starter, it

 

takes time for the machine to cool

 

down before restart. Allow unit to

Overload automatic reset has not

adequately cool before attempting

reset.

restart. If problem persists, check

 

amp setting on the motor starter

 

inside the electrical enclosure – it

 

should match the amps on the motor

 

as indicated on the motor plate.

 

 

 

One cause of overloading trips which

 

are not electrical in nature is too

 

heavy a cut. The solution is to take a

 

lighter cut. If too deep a cut is not the

Jointer frequently trips.

problem, then check the amp setting

on the overload relay. Match the full

 

 

load amps on the motor as noted on

 

the motor plate. If amp setting is

 

correct then there is probably a loose

 

electrical lead.

 

 

 

Verify that jointer is on a circuit of

Building circuit breaker trips or fuse

correct size. If circuit size is correct,

there is probably a loose electrical

blows.

lead. Check amp setting on motor

 

 

starter.

 

 

 

Examine motor starter for burned or

 

failed components. If damage is

 

found, replace starter. If no visible

 

damage found, have starter tested.

 

If you have access to a voltmeter, you

 

can separate a starter failure from a

Switch or motor failure (how to

motor failure by first, verifying

incoming voltage at 220+/-20 and

distinguish).

second, checking the voltage

 

between starter and motor at 220+/-

 

20. If incoming voltage is incorrect,

 

you have a power supply problem. If

 

voltage between starter and motor is

 

incorrect, you have a starter problem.

 

If voltage between starter and motor

 

is correct, you have a motor problem.

 

 

 

Clean motor of dust or debris to allow

Motor overheated.

proper air circulation. Allow motor to

 

cool down before restarting.

 

 

25

Image 25
Contents Part No. M-0460282 Inch JointerMore Information Warranty and ServiceTable of Contents Page Page Page Features of the 60B Jointer SpecificationsCrate #1 contents Installation and AssemblyCrate #2 contents Tools required for assemblyMounting Drive Belt Aligning PulleysMounting Pulley Guard Mounting Dust ChuteGrounding Instructions Electrical ConnectionsExtension Cords Converting from 230 Volt to 460 Volt Three Phase OnlyCutter Guard AdjustmentsRemoving Guard Mounting GuardInstalling Knives Leveling Tables Rapid Adjust Adjusting Depth of CutFine Adjust If table will still not line upExamples of incorrect settings Setting Outfeed TableSpring Cutting Fence Stops Fence MovementDegree stop Jointing Short or Thin Work Basic Jointer OperationDegree forward stop Degree back stopDirection of Grain Hand PlacementSurfacing Jointing Warped SurfacesBeveling Edge JointingSkewing Shear Cutting Rabbeting Taper CutsSharpening Knives MaintenanceCutterhead Repairs Table Removal Trouble Troubleshooting Operating ProblemsProbable Cause Remedy Troubleshooting Mechanical and Electrical Problems Replacement Parts Optional AccessoriesTrouble Probable Cause Remedy Index No. Part No Description Size Qty Parts List Base Assembly6296166 Base Assembly Parts List Fence Assembly Fence Assembly Parts List Cutterhead Assembly Parts List Stand Assembly 6823013 Stand Assembly Electrical Connections 230 Volt, Single Phase Electrical Connections 230 Volt, 3 Phase Electrical Connections 460 Volt, Three Phase Checklist for Model 60B Jointer Preventive MaintenanceWMH Tool Group