Bryant 661S, 661G, 661C instruction manual Safety Considerations, Installation Recommendations

Page 1

installation and

661C, G

start-up instructions

661S

10SEER SPLIT-SYSTEM HEAT PUMP

NOTE: Read the entire instruction manual before starting the installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thor- oughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements.

Recognize safety information. This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

WARNING: Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch(es) with a suitable warning label. Electrical shock can cause personal injury or death.

INSTALLATION RECOMMENDATIONS

NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.

1.Locate unit away from windows, patios, decks, etc. where unit operation sounds may disturb customer.

2.Ensure that vapor and liquid tube diameters are appropriate to capacity of unit.

3.Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.

4.Leave some slack between structure and unit to absorb vibration.

5.When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon-based caulk. (See Fig. 3.)

Cancels: II 661C-18-6

II 661C-18-7

 

2-02

A94355

Fig. 1—Models 661C

A98524

Fig. 2—Models 661G and 661S

6.Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls.

7.Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing. (See Fig. 3.)

8.Ensure that tubing insulation is pliable and completely surrounds vapor tube.

9.When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 3.)

10.Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.

—1—

Image 1
Contents Installation Recommendations Safety ConsiderationsII. Install on a SOLID, Level Mounting PAD Installation Check Equipment and JOB SiteDimensions III. Clearance RequirementsVIII. Make Piping Connections VII. Check Defrost ThermostatIX. Make Electrical Connections XII. Install Electrical AccessoriesCompressor Crankcase Heater XI. Compressor Crankcase HeaterBryant ONE Programmable Thermostat Other HP Thermostat Sequence of Operation l Phase Monitor ControlCare and Maintenance Heating Check Chart ProcedureXIV. Check Charge Defrost Control SPEED-UP Timing Sequence

661S, 661C, 661G specifications

The Bryant 661 series, comprising the models 661G, 661C, and 661S, represents a significant advance in heating and cooling technology, offering efficiency, reliability, and smart capabilities for modern homes. These models are designed to cater to various climate conditions while ensuring optimal comfort and energy savings.

The Bryant 661G model is primarily a gas furnace that boasts impressive AFUE (Annual Fuel Utilization Efficiency) ratings, which can exceed 96%. This efficiency translates into substantial savings on energy bills, making it an environmentally friendly choice. The 661G features a variable-speed blower motor, which adjusts airflow to meet specific heating needs. Additionally, its dual-stage gas valve allows for enhanced comfort and efficiency, providing a quiet operation and steady temperature control throughout the home.

The Bryant 661C model stands out with its focus on air conditioning capabilities. It utilizes advanced inverter technology that allows for precise temperature control and enhanced energy efficiency. With high SEER (Seasonal Energy Efficiency Ratio) ratings, the 661C significantly reduces energy consumption during hot months. Furthermore, the model is equipped with advanced filtration systems that ensure high indoor air quality by capturing allergens and pollutants, making it an excellent choice for allergy sufferers.

Lastly, the Bryant 661S is a comprehensive solution combining both heating and cooling in a single unit. This model is designed for versatility and efficiency, making it suitable for various residential applications. It offers smart technology integration, allowing homeowners to control their HVAC systems remotely via smartphone apps. The 661S's high-efficiency heat pump technology provides substantial savings in energy costs while maintaining optimal comfort year-round.

All three models feature durable construction with corrosion-resistant materials, ensuring longevity and minimal maintenance. The Bryant Comfort Shield technology enhances operational reliability by providing protection against environmental stressors. Moreover, the ease of installation and compatibility with existing Bryant systems adds to their appeal.

In conclusion, the Bryant 661G, 661C, and 661S models combine modern technology with energy-efficient performance, making them ideal choices for those looking to improve their home comfort while reducing energy costs. With their advanced features, homeowners can enjoy a cozy living environment while contributing to a more sustainable future.