Safety Instructions For Power Tools

9.USE PROPER EXTENSION CORD. Make sure your extension cord is in good condi- tion. Conductor size should be in accor- dance with the chart below. The amperage rating should be listed on the motor or tool nameplate. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Your extension cord must also contain a ground wire and plug pin. Always repair or replace exten- sion cords if they become damaged.

Minimum Gauge for Extension Cords

 

 

LENGTH

 

 

 

 

 

 

AMP RATING

25ft

 

50ft

100ft

 

 

 

 

 

0-6

16

 

16

16

 

 

 

 

 

7-10

16

 

16

14

 

 

 

 

 

11-12

16

 

16

14

 

 

 

 

 

13-16

14

 

12

12

 

 

 

 

 

17-20

12

 

12

10

21-30

10

 

10

No

 

 

 

 

 

10.WEAR PROPER APPAREL. Do not wear loose clothing, gloves, neckties, rings, bracelets, or other jewelry which may get caught in moving parts. Non-slip footwear is recommended. Wear protective hair cov- ering to contain long hair.

11.ALWAYS USE SAFETY GLASSES. Also use face or dust mask if cutting operation is dusty. Everyday eyeglasses only have impact resistant lenses, they are NOT safety glasses.

12.SECURE WORK. Use clamps or a vise to hold work when practical. It is safer than using your hand and frees both hands to operate tool.

13.NEVER OVERREACH. Keep proper foot- ing and balance at all times.

14.MAINTAIN TOOLS WITH CARE. Keep tools sharp and clean for best and safest performance. Follow instructions for lubri- cating and changing accessories.

15.DISCONNECT TOOLS before servicing and changing accessories, such as blades, bits, cutters, and the like.

16.REDUCE THE RISK OF UNINTENTIONAL STARTING. Make sure switch is in OFF position before plugging in.

17.USE RECOMMENDED ACCESSORIES. Consult the owner’s manual for recom- mended accessories. The use of improper accessories may cause risk of injury.

18.CHECK DAMAGED PARTS. Before fur- ther use of the tool, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended func- tion. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced.

19.NEVER LEAVE TOOL RUNNING UNATTENDED. TURN POWER OFF. Do not leave tool until it comes to a complete stop.

20.NEVER USE UNDER THE INFLUENCE of alcohol or drugs, or when tired.

21. NEVER ALLOW UNSUPERVISED OR

UNTRAINED PERSONNEL TO OPERATE THE MACHINE. Make sure any instruc- tions you give in regards to the operation of the machine are approved, correct, safe, and clearly understood.

Extreme Duty Planers

-3-

Image 11
Contents EXTREME-DUTY Planers Page Important Update Updated Main Wiring Diagram Model G9740/G9740Z/G9741 Wiring Safety Instructions WiringG9740/G9740Z/G9741/G9961/G9967 Update Mfg. Since 1/11 G9740/G9740Z/G9741/G9961/G9967/ Wiring 220V 440V Table Of Contents Safety Instructions For Power Tools Safety25ft 50ft 100ft Length AMP RatingRead this Entire Manual Before Turning the Planer on Additional Safety Instructions For PlanersGeneral Information Total Amperage Draw at Circuit RequirementsG9967/G9967Z G9740/G9740Z Recommended Plug and ReceptacleExtension Cords G9741/G9961GroundingTo rewire the planer Rewire toAbout this Section Machine FeaturesAbout this Section Unpacking SET UPG9740Z/G9961/G9967Z Spiral Cutterheads Part Qty Piece InventoryG9740/G9741/G9967 4-Knife Cutterheads Part Qty Hardware Recognition Chart Site Considerations Clean UpBeginning Assembly Dust Hood AssemblyTable Rollers To adjust the table rollers correctlyTest Run Operational Tips OperationsWood Characteristics Lubrication MaintenanceCleaning GeneralTo loosen/tighten belt tension BeltDate Approximate Hours Of Use Maintenance Performed Maintenance LogAdjustment Controls Service AdjustmentsAbout Service Cutterhead Knives To adjust the knife setCarbide Cutters Aftermarket Knife Setting JigsDisconnect the planer from the power source To install/adjust the carbide cuttersPage Cutterhead Page Hardwood Blocks Feed Rollers Pressure BarPage Chip deflector spring pressure controls Extreme Duty Planers Feed Roller Tension Chip DeflectorClosure Motors Machine Data SheetExtreme Duty Planer Model G9741/G9961 G9740/G9740Z/G9967/G9967Z/G9741/G9961 210 G9740/G9740Z/G9967/G9967Z/G9741/G9961 301 319 318 338 340 339341 337 336 335 322 324 325 320 PSS73M G9740/G9740Z/G9967/G9967Z/G9741/G9961 Table Roller 503 509 507 505 506 501 502 504 510 511 609 604 610 608 611 607 612 606 605 603 601 602 G9740/G9740Z/G9967/G9967Z/G9741/G9961 Outfeed Roller G9740/G9740Z/G9967/G9967Z/G9741/G9961 904 903 901 902 1010 1009 1008 1001 1006 1005 10031004 1011 1012 1002 PUSH-BUTTON Switch T1 G9740/G9740Z/G9967/G9967Z/G9741/G9961 G9740/G9740Z/G9967/G9967Z/G9741/G9961 G9740/Z Motor Cover G9740/G9740Z/G9967/G9967Z/G9741/G9961 1411 1407 1410 1401 1416 1409 1401-2 1401-1 1408 Transmission BOX 1502 1507 1509 1508 1510 1506 1505 15111506 1512 1503 1504 G9740/G9967/G9741 4-Knife Cutterhead G9740Z/G9967Z/G9961 Spiral Cutterhead Discharge Cover G9967/G9967Z Motors Voltage Diagram Volt Single PhaseTable Limit Switch Main Hook Up Panel Volt Single Phase G9740/G9740Z Volt 3-PhaseSwitch Plate Diagram Main Hook Up Panel Volt 3-Phase G9741/G9961 G9741/G9961 Main Hook Up Panel Volt 3-Phase Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC Page Call Today For a Free Full Color Catalog
Related manuals
Manual 76 pages 48.89 Kb Manual 82 pages 12.34 Kb