Bryant 213A Accessory Usage Guideline, Over 80 ft. / 24.38 m Within 2 miles / 3.22 km, Yes

Page 5

ACCESSORY USAGE GUIDELINE

 

REQUIRED FOR LOW--- AMBIENT

REQUIRED FOR

REQUIRED FOR

Accessory

COOLING APPLICATIONS

LONG LINE APPLICATIONS*

SEA COAST APPLICATIONS

 

(Below 55°F / 12.8°C)

(Over 80 ft. / 24.38 m)

(Within 2 miles / 3.22 km)

 

 

 

 

Accumulator

Standard

Standard

Standard

Ball Bearing Fan Motor

Yes{

No

No

Compressor Start Assist Capacitor and

Yes

Yes

No

Relay

 

 

 

 

 

 

 

Crankcase Heater

Yes

Yes

No

 

 

 

 

Evaporator Freeze Thermostat

Yes

No

No

Hard Shutoff TXV

Yes

Yes

Yes

Isolation Relay

Yes

No

No

Liquid Line Solenoid Valve

No

See Long--- Line Application

No

Guideline

 

 

 

 

 

 

 

Motor MasterControl or

Yes

No

No

Low Ambient Switch

 

 

 

 

 

 

 

Support Feet

Recommended

No

Recommended

*For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline.

{Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control.

Accessory Description and Usage (Listed Alphabetically)

213A

1. Ball-Bearing Fan Motor

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

Usage Guideline:

Required on all units when using MotorMasterr

2. Compressor Start Assist - Capacitor and Relay

Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.

Usage Guideline:

Required for reciprocating compressors in the following applications:

Long line

Low ambient cooling

Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil

Required for single-phase scroll compressors in the following applications:

Long line

Low ambient cooling

Suggested for all compressors in areas with a history of low voltage problems.

3. Compressor Start Assist — PTC Type

Solid state electrical device which gives a ”soft” boost to the compressor at each start-up.

Usage Guideline:

Suggested in installations with marginal power supply.

4. Crankcase Heater

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.

Usage Guideline:

Required in low ambient cooling applications. Required in long line applications.

Suggested in all commercial applications.

5. Evaporator Freeze Thermostat

An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.

Usage Guideline:

Required when low ambient kit has been added.

6. Isolation Relay

An SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode.

Usage Guideline:

Required in all heat pumps where low ambient kit has been added.

7. Liquid-Line Solenoid Valve (LLS)

An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode.

Usage Guideline:

An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline.

8. Low-Ambient Pressure Switch Kit

A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low-ambient temperatures down to 0_F (-18_C) when properly installed.

Usage Guideline:

ALow-Ambient Pressure Switch or MotorMasterr Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

9.MotorMasterr Low-Ambient Controller

Afan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 6.5_C).

Usage Guideline:

A MotorMasterr Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

Suggested for all commercial applications.

5

Image 5
Contents Product Data Industry Leading Features / BenefitsModel Number Nomenclature Standard FeaturesSeer RNCVapor Line Sizing and Cooling Capacity Loss Physical DataAccessory Thermostats AccessoriesTSTATXXSEN01---B PHPYes Accessory Usage GuidelineOver 80 ft. / 24.38 m Within 2 miles / 3.22 km Outdoor Air Temperature Sensor Weighted Sound Power with Sound Hood Weighted Sound PowerElectrical Data Charging Subcooling TXV-TYPE Expansion DeviceDimensions English Dimensions SI Heat LOSS, Unit Integrated Heating CAPACITY, Mbtuh Building 213A Balance Point WorksheetClearances Wall 609.6 Service 457.2Combination Ratings Combination Ratings FY4ANF036 FF1ENP036FY4ANF042 Combination Ratings FV4BNB006 FE4ANB006+UIFY4ANF048 Combination Ratings FY4ANB060 59500 11.2 13.50 57000 36000 3027414 213ANA060---D Combination Ratings 213ANA018---E Outdoor Section With FY4ANF018 Indoor Section Detailed Cooling CAPACITIES#700 213ANA024---C Outdoor Section With FY4ANF024 Indoor Section800 900875 213ANA030---D Outdoor Section With FY4ANF030 Indoor Section1000 1125Detailed Cooling CAPACITIES# 1050 213ANA036---D Outdoor Section With FY4ANF036 Indoor Section1200 1350Detailed Cooling CAPACITIES# 213ANA042--- COutdoor Section With FY4ANF042 Indoor Section Capacity MBtuh Total1225 1400213ANA042---C Outdoor Section With FY4ANF042 Indoor Section 1600 213ANA048---D Outdoor Section With FY4ANF048 Indoor Section1800 FY4ANB060Model 213ANA060---D Outdoor Section With FY4ANB060 Indoor Section Section With FY4ANF018 Indoor Section Heat Pump Heating Performance213ANA024---C Outdoor Section With FY4ANF024 Indoor Section 213ANA030---D Outdoor Section With FY4ANF030 Indoor Section 213ANA036---D Outdoor Section With FY4ANF036 Indoor Section See notes on 213ANA042---C Outdoor Section With FY4ANF042 Indoor Section Heat Pump Heating Performance 213ANA048---D Outdoor Section With FY4ANF048 Indoor Section 213ANA060---D Outdoor Section With FY4ANB060 Indoor Section Products Guide Specifications GeneralCatalog No. PDS213A
Related manuals
Manual 32 pages 35.64 Kb

213A specifications

The Bryant 213A is a cutting-edge system known for its impressive performance and reliability in heating and cooling applications. Designed for residential and light commercial use, it stands out due to its efficiency and innovative features, making it a popular choice among homeowners and contractors alike.

One of the main features of the Bryant 213A is its advanced two-stage cooling and heating capability. This allows for more precise temperature control and enhanced comfort. By adjusting its output based on the current demand, the unit operates at lower speeds during moderate conditions, which helps in saving energy while still maintaining desired comfort levels.

Efficiency is another hallmark of the Bryant 213A. It boasts a high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER), making it one of the most energy-efficient systems in the market. This efficiency not only contributes to lower energy bills but also helps in reducing the environmental footprint of the home, making it a greener choice for those conscious of their energy consumption.

The 213A leverages state-of-the-art technology such as a variable-speed compressor and advanced refrigerant management. This technology facilitates smooth operation and minimizes temperature fluctuations. Additionally, the unit is designed for quiet operation, which means it can efficiently cool or heat a home without intrusive noise, resulting in a more comfortable living environment.

Installation flexibility is another significant advantage of the Bryant 213A. The system is compatible with various ductwork configurations and can be easily integrated into existing HVAC systems. This adaptability makes it suitable for different home sizes and layouts, providing solutions for both new constructions and retrofits.

Durability is a core characteristic of the Bryant 213A. Crafted with high-quality materials and backed by a robust warranty, it ensures longevity and dependable performance. The unit is built to withstand various weather conditions and is designed with low maintenance in mind, further enhancing its appeal.

In conclusion, the Bryant 213A combines efficiency, advanced technology, and durability, making it an exceptional choice for heating and cooling needs. Its innovative features, quiet operation, and adaptability to different home environments set it apart in the HVAC landscape. Selecting the Bryant 213A ensures a comfortable, energy-efficient, and reliable climate control solution for any modern home.