Bryant 213A warranty Outdoor Air Temperature Sensor

Page 6

Accessory Description and Usage (Listed Alphabetically) - CONTINUED

213A

10. Outdoor Air Temperature Sensor

Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for all Bryant thermostats listed in this publication.

11. Outdoor Thermostat

An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point.

Usage Guideline:

Electric supplemental heat applications in non-variable speed indoor units when electric heat staging is desired.

12. Secondary Outdoor Thermostat

An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point.

Usage Guideline:

Outdoor thermostat applications where electric heater is capable of 3-stage operation.

13. Snow Stand Rack

Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base.

Usage Guideline:

Suggested in the following applications:

Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations.

Heat pump installations in areas of prolonged subfreezing temperatures.

All commercial installations.

14. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft.

(4.577 m) to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft. (3.05 m) apart.

15. Thermostatic Expansion Valve (TXV) Bi-Flow

Amodulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Usage Guideline:

Accessory required to meet ARI rating and system reliability, where indoor not equipped.

Required in all heat pump applications designed with Puron refrigerant.

16. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

Accessory required to meet ARI rating, where indoor not equipped.

6

Image 6
Contents Industry Leading Features / Benefits Product DataSeer Standard FeaturesModel Number Nomenclature RNCPhysical Data Vapor Line Sizing and Cooling Capacity LossTSTATXXSEN01---B AccessoriesAccessory Thermostats PHPAccessory Usage Guideline Over 80 ft. / 24.38 m Within 2 miles / 3.22 kmYes Outdoor Air Temperature Sensor Electrical Data Weighted Sound PowerWeighted Sound Power with Sound Hood Charging Subcooling TXV-TYPE Expansion DeviceDimensions English Dimensions SI 213A Balance Point Worksheet Heat LOSS, Unit Integrated Heating CAPACITY, Mbtuh BuildingWall 609.6 Service 457.2 ClearancesCombination Ratings Combination Ratings FF1ENP036 FY4ANF036FY4ANF042 Combination Ratings FE4ANB006+UI FV4BNB006FY4ANF048 Combination Ratings FY4ANB060 59500 11.2 13.50 57000 36000 3027414 213ANA060---D Combination Ratings Detailed Cooling CAPACITIES# 213ANA018---E Outdoor Section With FY4ANF018 Indoor Section800 213ANA024---C Outdoor Section With FY4ANF024 Indoor Section700 9001000 213ANA030---D Outdoor Section With FY4ANF030 Indoor Section875 1125Detailed Cooling CAPACITIES# 1200 213ANA036---D Outdoor Section With FY4ANF036 Indoor Section1050 1350Detailed Cooling CAPACITIES# 1225 Capacity MBtuh Total213ANA042--- COutdoor Section With FY4ANF042 Indoor Section 1400213ANA042---C Outdoor Section With FY4ANF042 Indoor Section 1800 213ANA048---D Outdoor Section With FY4ANF048 Indoor Section1600 FY4ANB060Model 213ANA060---D Outdoor Section With FY4ANB060 Indoor Section Heat Pump Heating Performance Section With FY4ANF018 Indoor Section213ANA024---C Outdoor Section With FY4ANF024 Indoor Section 213ANA030---D Outdoor Section With FY4ANF030 Indoor Section 213ANA036---D Outdoor Section With FY4ANF036 Indoor Section See notes on 213ANA042---C Outdoor Section With FY4ANF042 Indoor Section Heat Pump Heating Performance 213ANA048---D Outdoor Section With FY4ANF048 Indoor Section 213ANA060---D Outdoor Section With FY4ANB060 Indoor Section Guide Specifications General ProductsCatalog No. PDS213A
Related manuals
Manual 32 pages 35.64 Kb

213A specifications

The Bryant 213A is a cutting-edge system known for its impressive performance and reliability in heating and cooling applications. Designed for residential and light commercial use, it stands out due to its efficiency and innovative features, making it a popular choice among homeowners and contractors alike.

One of the main features of the Bryant 213A is its advanced two-stage cooling and heating capability. This allows for more precise temperature control and enhanced comfort. By adjusting its output based on the current demand, the unit operates at lower speeds during moderate conditions, which helps in saving energy while still maintaining desired comfort levels.

Efficiency is another hallmark of the Bryant 213A. It boasts a high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER), making it one of the most energy-efficient systems in the market. This efficiency not only contributes to lower energy bills but also helps in reducing the environmental footprint of the home, making it a greener choice for those conscious of their energy consumption.

The 213A leverages state-of-the-art technology such as a variable-speed compressor and advanced refrigerant management. This technology facilitates smooth operation and minimizes temperature fluctuations. Additionally, the unit is designed for quiet operation, which means it can efficiently cool or heat a home without intrusive noise, resulting in a more comfortable living environment.

Installation flexibility is another significant advantage of the Bryant 213A. The system is compatible with various ductwork configurations and can be easily integrated into existing HVAC systems. This adaptability makes it suitable for different home sizes and layouts, providing solutions for both new constructions and retrofits.

Durability is a core characteristic of the Bryant 213A. Crafted with high-quality materials and backed by a robust warranty, it ensures longevity and dependable performance. The unit is built to withstand various weather conditions and is designed with low maintenance in mind, further enhancing its appeal.

In conclusion, the Bryant 213A combines efficiency, advanced technology, and durability, making it an exceptional choice for heating and cooling needs. Its innovative features, quiet operation, and adaptability to different home environments set it apart in the HVAC landscape. Selecting the Bryant 213A ensures a comfortable, energy-efficient, and reliable climate control solution for any modern home.