6-4. Troubleshooting
|
|
|
|
|
|
|
|
|
|
| Trouble |
| Remedy | |
|
| |||
No weld output; unit completely inop- | Place line disconnect device in On position (see Section | |||
erative; pilot light PL1 off. |
|
| ||
|
|
|
| |
|
|
| Check for open line fuse(s), and replace if open (see Section | |
|
|
|
| |
|
|
| Check for proper input power connections (see Section | |
|
|
|
| |
|
|
| Check for proper jumper link position (see Section | |
|
|
|
| |
|
|
| Check fuse F1, and replace if necessary (see Section | |
|
| |||
Meter displays a HELP message. | If meters display a HELP message, see Section | |||
|
| |||
No weld output; pilot light PL1 on. | Unit overheated. Allow unit to cool with fan On (see Section | |||
|
|
|
| |
|
|
| If using remote control, place Panel/Remote control switch in Remote position, and connect remote | |
|
|
| control (see Sections | |
|
|
| Section | |
|
|
|
| |
|
|
| Check position of Mode switch (see Section | |
|
|
|
| |
|
|
| Check, repair, or replace remote control. | |
|
| |||
Limited weld output and low | Check position of Panel/Remote control switch (see Section | |||
|
| |||
|
|
|
| |
|
|
| Check for open line fuse(s), and replace if open (see Section | |
|
|
|
| |
|
|
| Check for proper input power connections (see Section | |
|
|
|
| |
|
|
| Check for proper jumper link position (see Section | |
|
|
|
| |
|
|
| Clean and tighten all weld output connections. | |
|
| |||
Unit provides only maximum or mini- | Check position of Panel/Remote control switch (see Section | |||
mum weld output. |
|
| ||
|
|
|
| |
|
|
| Have Factory Authorized Service Agent check control board PC1, front panel display board PC2, | |
|
|
| pulser interface board PC3, and hall device HD1. | |
|
| |||
Erratic or improper weld output. | Use proper size and type of weld cable (see Section | |||
|
|
|
| |
|
|
| Clean and tighten all weld connections. | |
|
|
|
| |
|
|
| Check wire feeder installation according to Owner’s Manual. | |
|
|
|
| |
|
|
| Check position of Mode switch (see Section | |
|
|
|
| |
|
|
| Have Factory Authorized Service Agent check control board PC1, front panel display board PC2, | |
|
|
| pulser interface board PC3, and hall device HD1. | |
|
| |||
No 115 volts AC output at duplex re- | Reset circuit breaker CB1 (see Section | |||
ceptacle or Remote 14 receptacle. |
|
| ||
|
| |||
No 24 volts AC output at Remote 14 | Reset circuit breaker CB2 (see Section | |||
receptacle. |
|
| ||
|
| |||
Fan not operating. Note: If unit has | Check for and remove anything blocking fan movement. | |||
|
| |||
when cooling is required. |
|
| ||
|
|
|
| |
|
|
| Have Factory Authorized Service Agent check fan motor. | |
|
| |||
Wandering arc; poor control of arc di- | Reduce gas flow rate. | |||
rection. |
|
| ||
|
|
|
| |
|
|
| Select proper size tungsten. | |
|
|
|
| |
|
|
| Properly prepare tungsten. | |
|
| |||
Tungsten electrode oxidizing and not | Shield weld zone from drafts. | |||
remaining bright after conclusion of |
|
| ||
weld. |
|
| ||
|
|
|
| |
|
|
| Increase postflow time. | |
|
|
|
| |
|
|
| Check and tighten all gas fittings. | |
|
|
|
| |
|
|
| Properly prepare tungsten. | |
|
|
|
| |
|
|
| Check for water in torch, and repair torch if necessary. See torch Owner’s Manual. | |
|
| |||
Digital meter not working properly. | Have Factory Authorized Service Agent check front panel display board PC2 and connections, and re- | |||
|
|
| place if necessary. | |
|
|
|
|
|