TROUBLESHOOTING

This section describes how to find and resolve problems users may experience. If a situation occurs that is not covered, call your Stanley Customer Service represen- tative for assistance.

WARNING

Inspecting the tool or installing parts with the hydraulic hoses connected can result in severe personal injury or equipment damage. To prevent accidental startup, disconnect the hydraulic power before beginning any inspection or installation task.

If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.

When diagnosing faults in operation of the tool, always check that the hydraulic power source is supplying the correct hydraulic flow and pressure to the tool as listed in the table below. Use a flowmeter known to be accu- rate. Check the flow with the hydraulic oil temperature at least 80 °F/27 °C.

PROBLEM

CAUSE

SOLUTION

Breaker will not fire.

Low hydraulic oil level.

Fill reservoir.

 

No flow to breaker.

Have hydraulic circuit tested by

 

Main relief set low.

authorized dealer/distributor per

 

 

approved procedure.

 

Internal damage.

Have unit serviced by an authorized

 

 

dealer/distributor.

 

Damaged quick couplers.

Replace.

Breaker runs slowly.

Low hydraulic flow

Have hydraulic circuit tested by an

 

Excessive heat build up.

authorized dealer/distributor per

 

 

approved procedure.

 

Excessive nitrogen pressure.

Have unit serviced by an authorized

 

 

dealer/distributor.

 

Internal leakage.

Breaker runs erratically.

Low or excessive back-pressure.

Have carrier serviced by an authorized

 

 

dealer/distributor.

 

Damaged switch or connection.

 

Relief set too low.

 

 

Internal damage.

 

 

Tool binding.

Add grease to tool shank. Do not pry

 

 

while operating.

Breaker runs but at reduced

Low accumulator charge.

Have unit serviced by an authorized

power.

Excessive back-pressure.

dealer/distributor.

 

Relief set too low.

 

Breaker leaks oil around tool bit

Lower seals failed.

Have unit serviced by an authorized

and tool bushing.

 

dealer/distributor.

Hydraulic system overheats.

Main relief set low.

Have unit serviced by an authorized

 

 

dealer/distributor.

 

Insufficient cooling capability in

 

hydraulic circuit.

 

 

Line/hose size too small.

 

 

Excessive back-pressure.

 

MB656 User Manual ◄ 15

Image 15
Contents MB656 Weisbeck, Andy Declaration of ConformityTable of Contents Local Safety Regulations Safety SymbolsSafety Precautions Obey Safety Rules Be Thoroughly Trained Before Operating the Unit AloneKnow the Work Conditions Parking Brake Tool Stickers & Tags 66219 Guaranteed Sound Power Level StickerPRE-INSTALLATION Instructions PRE-OPERATION ProceduresOperation Positioning the Carrier Operating a BreakerLong Term Storage Preparation for USEBackhoes Positioning the Breaker Tool on the Work MaterialBreaking Maintain Down PressureBlank Firing Grease the BIT Underwater UsageProblem Cause Solution TroubleshootingMaintenance Daily Maintenance ChecksTool Stop and Lower Bushing Normal Charging the AccumulatorHose Routings Flow Control KIT InstructionsRetainer PIN Item Wear TolerancesLower Bushing Item Tool Stop ItemBlank Firing or Free Running Tool Failure not Covered Under WarrantyWORN-OUT Front Bushings or Retainer Pins Proper USE & Care of Tool BitsCorrosion PryingInternal Material Flaw Tool Failure Covered Under WarrantyMoil ChiselBlunt Test Procedure Flow Test ProceduresHeat Load Test TroubleshootingTool DefinitionsDimensions and Weights SpecificationsMiscellaneous AccessoriesMB656 Power Cell Illustration Housing Parts Illustration Charge Valve Assy Incl MB656 Parts ListMB656 Mounting Brackets Page Stanley Hydraulic Tools SE Naef Road Milwaukie, Oregon