SPECIFICATIONS

DIMENSIONS AND WEIGHTS

 

 

 

 

 

 

Weight w/Tool Bit, & Mounting Bracket

.................................................................................................

 

 

 

 

872 lbs/396 kg

Length w/Tool Bit & Mounting Bracket

 

 

 

66.5 in./1689 mm

Tool Working Length

 

 

 

 

18 in./457 mm

Tool Diameter

 

 

 

 

 

 

3 in./76 mm

Hydraulic Pressure (working)

 

 

1700–1900 psi/117–131 bar

Flow Range

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

16 gpm/60 lpm

Maximum

 

 

 

 

 

 

24 gpm/91 lpm

System Relief (min. cracking)

 

 

 

2500 psi/172 bar

Return Line Pressure (max.)

 

 

 

 

350 psi/24 bar

Operating Oil Temperature (max.)

 

 

 

 

190 °F/88 °C

Adapter Fitting Size

 

 

 

 

-12 SAE O-ring

Recommended Min. Hose ID

 

 

 

 

3/4 in.

Blows Per Minute

 

 

 

 

 

600 min./1000 max.

Impact Energy Class

 

 

 

875 ft lb/1200 J

Sound Power Level

 

 

 

 

121 dBA

Carrier Size (Skidsteer)

 

12000-14400 lb / 5448-6538 kg

Carrier Size (Mini Excavator)

 

 

9100-20000 lb / 4131-9000 kg

Carrier Size (Backhoe)

 

 

9100-20000 lb / 4131-9000 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TORQUE TABLE

 

 

 

 

 

 

Item No.

 

Illustration

 

Description

Apply

 

Ft/Lb

 

Nm

 

46

 

Power Cell

 

Hollow Hex Plug -12 SAE

Loctite™ 242

 

150

 

203

 

32

 

Power Cell

 

Tie Rod Nut

Kopr Kote™

 

650

 

881

 

6

 

Power Cell

 

Charge Valve

Loctite™ 242

 

80

 

108

 

13

 

Power Cell

 

Capscrew

Loctite™ 242

 

85

 

115

 

60

 

Housing

 

Capscrew

Kopr Kote™

 

455

 

617

 

58

 

Housing

 

Nut

Kopr Kote ™

 

455

 

617

 

11

 

Power Cell

 

Accumulator Cap

Anti-Seize

 

200

 

271

 

NOTES FOR ITEM 30 ASSEMBLY:

Tighten in a cross pattern.

Thread into nut by hand.

Thread tie rod into nut by hand.

Use Loctite™ to prevent plug from falling out. If plug falls out, the housing will fill with grease. The power cell must be removed to repair.

NOTE: Weights, dimensions and operating specifications listed on this sheet are subject to change with- out notice. Where specifications are critical to your application, please consult the dealer.

MB656 User Manual ◄ 27

Image 27
Contents MB656 Weisbeck, Andy Declaration of ConformityTable of Contents Local Safety Regulations Safety SymbolsSafety Precautions Obey Safety Rules Be Thoroughly Trained Before Operating the Unit AloneKnow the Work Conditions Parking Brake Tool Stickers & Tags 66219 Guaranteed Sound Power Level StickerPRE-INSTALLATION Instructions PRE-OPERATION ProceduresOperation Positioning the Carrier Operating a BreakerLong Term Storage Preparation for USEBackhoes Positioning the Breaker Tool on the Work MaterialBreaking Maintain Down PressureBlank Firing Grease the BIT Underwater UsageProblem Cause Solution TroubleshootingMaintenance Daily Maintenance ChecksTool Stop and Lower Bushing Normal Charging the AccumulatorHose Routings Flow Control KIT InstructionsRetainer PIN Item Wear TolerancesLower Bushing Item Tool Stop ItemBlank Firing or Free Running Tool Failure not Covered Under WarrantyWORN-OUT Front Bushings or Retainer Pins Proper USE & Care of Tool BitsCorrosion PryingInternal Material Flaw Tool Failure Covered Under WarrantyMoil ChiselBlunt Test Procedure Flow Test ProceduresHeat Load Test TroubleshootingTool DefinitionsDimensions and Weights SpecificationsMiscellaneous AccessoriesMB656 Power Cell Illustration Housing Parts Illustration Charge Valve Assy Incl MB656 Parts ListMB656 Mounting Brackets Page Stanley Hydraulic Tools SE Naef Road Milwaukie, Oregon