SPECIFICATIONS

Pressure Range

1500–2000 psi/105–140 bar

Flow Range

7–9 gpm / 26–34 lpm

Nominal Flow

8 gpm / 30 lpm

Maximum Back Pressure

250 Psi/17 bar

Connect Size & Type

3/8 in. Male Pipe Hose Ends

Weight

80 lbs / 36 kg

Length

27 in. / 68 cm

Width

16 in. / 40 cm

System Type

Open or Closed Center

 

HTMA Type II

Port Size

SAE 8 O-ring

HTMA/EHTMA Category

Type 2

Nominal Pressure

1500 psi/103 bar

Max Pressure

2000 psi/138 bar

Max Relief Pressure

2150 psi/148 bar

BR87 SOUND AND VIBRATION DECLARATION

Test conducted on BR8713201,operated at 8 gpm input

 

Measured A-weighted sound power level, Lwa (ref. 1pW) in decibels

105 dBA

Uncertainty, Kwa, in decibels

1.6 dBA

Guaranteed sound power level

106 dBA

Measured A-weighted sound pressure level, Lpa (ref. 20 µPa) at operator's position, in decibels

102 dBA

Uncertainty, Kpa, in decibels

3 dBA

Values determined according to noise test code given in ISO 15744, using the basic standard ISO3744. Test conducted by independent notified body to comply with 2000/14/EC:2005 requirements.

NOTE- The sum of a measured noise emission value and its associated uncertainty represents an upper bound- ary of the range of values which is likely to occur in measurements.

Declared vibration emission value in accordance with EN 12096

 

Measured vibration emission value: 3-Axis

22.1m/sec²

Uncertainty: K

2.9 m/sec²

Measured vibration emission value with uncertainty: 3-Axis

25.0 m/sec²

Measured vibration emission value: Z-Axis

18.4 m/sec²

Uncertainty: K

2.6 m/sec²

Measured vibration emission value with uncertainty: Z-Axis

21.0 m/sec²

Values determined according to ISO 8662-5, ISO 5349-1,2

 

16 ► BR87 User Manual

Image 16 Contents
Hydraulic Breaker Declaration of Conformity Weisbeck, AndyTable of Contents Safety Symbols Local Safety RegulationsSafety Precautions Safety Precautions Tool Stickers & Tags N G E RHose Safety Tags Hose TypesHose Recommendations Tool to Hydraulic Circuit Hose RecommendationsHtma / Ehtma Requirements Htma / Ehtma RequirementsPRE-OPERATION Procedures Operation ProceduresOperation Cold Weather OperationTool Protection & Care Troubleshooting Problem Cause RemedyAccumulator Testing Procedure General Service NotesCharging the Accumulator Accumulator ChargingUnderwater Model Preventative Maintenance Specifications BR87 Sound and Vibration DeclarationService Tools AccessoriesTest Equipment BR87 Parts Illustration BR87 Parts Illustration BR87 Parts List Part Qty DescriptionUnderwater Models only Underwater Tools Depth GuidelineGPM