Miller Electric S-74S, S-74D manual Equipment DIP Switch Settings For Models With Meters Only

Page 20

5-8. Equipment DIP Switch Settings (For Models With Meters Only)

 

 

 

 

 

 

 

Remove wrapper.

 

 

 

 

 

 

 

Install wrapper when finished.

Digital Meter Functions

 

 

 

Standard

 

 

Standard

High Speed

 

 

High Speed

Motor

 

 

Motor

Motor

 

 

Motor

Inches/Minute

Meters/Minute

Inches/Minute

Meters/Minute

5

 

 

5

5

 

 

5

4

 

 

4

4

 

 

4

3

Or

3

3

Or

3

 

 

 

 

2

 

 

2

2

 

 

2

1

 

 

1

1

 

 

1

 

 

Tools Needed:

 

 

 

 

 

 

 

1/4 in

 

 

 

 

 

 

 

 

 

 

Ref. 802 946

OM-1500-10 Page 16

 

 

 

 

 

 

 

Image 20
Contents OM-1500-10 207 748K ProcessesDescription File MIG GmawFrom Miller to You Table of Contents Directives StandardsSymbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux LE Soudage peut provoquer un Incendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaques+ + Symbols And Definitions Rating Label For CE ProductsSpecifications Type of Input Welding Power Wire Feed OverallSite Selection RatingRear Panel Connections And Rotating Drive Assembly Wire Type, Size, And Feed Speed Capability Table Motor Speed Wire Type Wire Size Feed Speed CapabilityPin Plug PLG12 Information Gun Recommendation TableInstalling And Threading Welding Wire Nonconductive SurfaceSetting Internal DIP Switches Setting Current Detect Override S1-1Current Detect Override OFF Factory Default S1-1 And S1-2 Automatic Run-In OFF S1-1 And S1-2Equipment DIP Switch Settings For Models With Meters Only Power Switch Jog/PurgeTrigger Hold Switch You can adjust the preset voltMonths Routine MaintenanceDisconnect power before maintaining Error Indications DiagnosticsIndicated Error Trouble Remedy TroubleshootingDisconnect power before troubleshooting − Electrical Diagram OM-1500-10 − Parts List Part Description Quantity Control Box Diagram Part Quantity Model Marking Description 74S 74D Drive Assembly, Wire PLG5 Roll Kit Drive Roll Drive Roll And Wire Guide Kits Wire Size GuideInletRoll Kit Drive Roll Fraction Metric Service SupportOwner’s Record Miller Electric Mfg. Co