SECTION 6 − OPERATION
6-1. Power Switch
1 Power Switch
1
802
6-2. Jog/Purge
2
3
1
1Jog/Purge Push Button
2Wire Speed Control
3Gun Trigger Receptacle
Pressing the Jog/Purge switch al- lows the operator to jog wire without energizing the weld power or gas valve circuit.
•The wire feeder can also be jogged by using the gun trigger. However, the contactor is ener- gized for 3 seconds.
•If the welding arc does not initiate in 3 seconds after the gun trigger is activated the unit will perform a jog operation for a maximum of two minutes. If the gun trigger is still activated after two minutes, the jog operation is terminated to prevent complete despooling of the wire, as in the case of a dam- aged gun.
•Jog speed can be adjusted with the Wire Speed control when the unit is jogging wire. If equipped with meters, the unit displays jog speed while the unit is being jogged.
•Pressing the Jog/Purge button also allows the operator to purge gas lines before welding and to preset gas pressure at the regu- lator.
802