Miller Electric S-64, S-62 Pin Plug Information, Wire Type, Size, And Feed Speed Capability Table

Page 18

4-5. 14-Pin Plug Information

 

 

 

Pin*

Pin Information

 

 

 

A

24 volts ac with respect to socket G.

 

 

 

B

Contact closure to A completes 24 volts ac contactor control circuit.

J

K

A

G

Circuit common for 24 volts AC circuit.

 

 

I

B

C

+10 volts dc output to remote control with respect to socket D.

 

 

 

 

L C

H

N

D

Remote control circuit common.

G

M

D

 

 

F

E

 

E

0 to +10 volts dc input command signal from remote control with respect to socket D.

 

 

 

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

 

 

 

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

*The remaining pins are not used.

4-6. Wire Type, Size, And Feed Speed Capability Table

Motor Speed

Wire Type

Wire Size

Feed Speed Capability

 

 

 

 

Standard

All

.023 To 5/64 in (0.6 To 2 mm)

50 To 780 ipm (1.3 To 19.8 mpm)

 

 

 

 

Standard

All

3/32 To 7/64 in (2.4 To 2.8 mm)

50 To 700 ipm (1.3 To 17.8 mpm)

 

 

 

 

 

Standard

All

1/8 in (3.2 mm)

50 To 300 ipm (1.3

To 7.6 mpm)

 

 

 

 

 

Optional High

All

.023 To 5/64 in (0.6 To 2 mm)

92 To 1440 ipm (2.3

To 35.6 mpm)

Speed

 

 

 

 

 

 

 

 

 

4-7. Motor Start Control

2

1

3

Tools Needed:

Non-Conductive

1/4 in

To change wire feed starting speed proceed as follows:

Turn Off unit and welding power source.

Remove wrapper.

1 Front Panel

Remove screw from upper left cor- ner, and open hinged front panel.

2Motor Board PC1

3Motor Start Control Potentiometer R70

Rotate potentiometer clockwise to increase time it takes the motor to ramp up to speed. Remove protec- tive white rubber cap before making adjustment. Adjust potentiometer R70 using a small nonconductive screwdriver.

Close and secure front panel, and reinstall wrapper.

802 479 / Ref. 183 121-C

OM-1579 Page 14

Image 18
Contents OM-1579 ProcessesDescription From Miller to You Table of Contents Directives StandardsArc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersUN Choc É Lectrique peut tuer Signification des symbolesConsignes DE Securite Lire Avant Utilisation LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Soudage peut provoquer un incendie ou une explosion DES Particules Volantes peuvent blesser les yeuxLE Bruit peut affecter l’ouïe ’EMPLOI Excessif peut Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sé curité Information sur les champs é lectromagné tiquesConsignes relatives aux stimulateurs cardiaques + + + DefinitionsSymbols And Definitions Rating Label For CE Products Introduction Installation Specifications Site SelectionEquipment Connection Diagrams Gun Recommendation TableRear Panel Connections And Rotating Drive Assembly Pin Plug Information Wire Type, Size, And Feed Speed Capability TableMotor Speed Wire Type Wire Size Feed Speed Capability Motor Start ControlInstalling And Threading Welding Wire To adjust drive roll pressure, hold nozzleOptional Equipment DIP Switch Settings Spot Time Range SelectionOption Interface Standard SettingsVoltage Sensing Function Operation Front Panel ControlsDisconnect power before maintaining Maintenance and TroubleshootingRoutine Maintenance Overload Protection And Optional Side Panel ControlsTroubleshooting Disconnect power before troubleshootingElectrical Diagram Circuit Diagram196 503-A Parts List Main AssemblyOptional Control Box Control Box -1 Item Control Panel Control Panel -2 Item Drive Assembly, Wire Drive Assembly, Wire -1 Item Drive Roll And Wire Guide Kits Fraction Metric Kit Roll Wire SizeRoll Drive Service SupportOwner’s Record Miller Electric Mfg. Co