6-7. Lower Display

5

Time

1

2

WFS

Amps

Arc Ctl

3 4

7

6

1 Lower Display

The lower display shows WFS (wire feed speed), AMPS (amperage), ARC CTL (arc control), or Time. The feeder displays only preset wire speed at idle (not welding). While welding, the average amperage is displayed. The lower display shows welding sequence time when the Time LED is illuminated.

2 WFS (Wire Feed Speed) LED

LED illuminates to indicate the preset wire feed value is being displayed and can be adjusted using the Adjust knob.

3 Amps LED

LED illuminates to indicate the average amperage is being displayed while welding and for 3 seconds after welding is terminated. The amperage must be above a minimum value of 25 amps for this function to operate.

4 Arc Ctl (Arc Control) LED

LED illuminates to indicate that inductance (MIG) or ARC [Pulse, Accu-pulse, or RMD (optional)] is being displayed and can be ad- justed using the Adjust knob.

5 Time LED

LED illuminates to indicate that a time value is being displayed for a sequence function and can be adjusted using the Adjust knob.

6Lower Display Push Button

7Lower Display Push Button LED

Pressing the button illuminates the LED and selects either WFS or Arc Ctl value for changing using the Adjust knob.

To select Arc Ctl, press and hold lower display button for 2 seconds. The top display will show either INDU for a MIG program or ARC for Pulse, Accu-pulse, or RMD (optional). To exit Arc Ctl or INDU, either press the upper display push button or press and hold the lower display push button for 2 seconds.

When the lower display push-button LED and the WFS LED are both illuminated, it is possible to change WFS while welding by using the Adjust knob. The value in the display will switch momentarily to show preset wire feed speed while turning the Adjust knob and revert back to actual value when adjustment is completed.

When the Arc Ctl LED is illuminated, it is pos- sible to change values while welding by using the Adjust knob. To return to actual values on the display, exit the Arc Ctl display.

.The lower display push button has addi-

tional functions when entering the se- quence and trigger control functions (see Section 6-8).

OM-222 394 Page 21

Image 25
Contents Processes OM-222 394FDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers LES Fumées ET LES GAZ peuvent être dangereux UNE Décharge Électrique peut entraîner la mortIndique un message de sécurité particulier Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéSpecifications − Installation− Introduction Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Gun Recommendation Table Pin Network Receptacle InformationInstalling And Threading Welding Wire Dual Schedule Switch Option Power Source Display At Power UpPower Source Upper Display Lower Display Voltage Range Operational Terms − OperationGeneral Terms Sequence Feeder Set UpPreflow StartLeft/Right Select Switch Power SwitchPower Switch Jog/Purge switch provides the following functions Jog/Purge Push Button Gun Trigger Receptacle Adjust KnobJog/Purge Front Panel Sections Program Push Button Volts Arc AdjustUpper Display Upper DisplayLower Display Adjust Knob Feeder Set Up Push ButtonSequence Trigger Control Trigger Hold Feeder Set Up CO2 Process Set Up Push ButtonPulse Reset ModeMild Steel Accu-pulseSequence Parameters In a Program − Setting Sequence ParametersSequence Parameters Routine Maintenance − MaintenanceDiagnostics Indicates a trigger Closed errorDisconnect power before troubleshooting TroubleshootingTrouble Remedy Circuit Diagram − Electrical Diagram218 564-D 21 − Figure − Parts ListPart Description Quantity Control Box PC1 Drive Assembly, Wire -1Item Drive Assembly, Wire1.2 mm Metric1.4 mm Page Your distributor also gives ServiceSupport Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s