Miller Electric DB1712RDI25 Maintenance & Troubleshooting, Routine Maintenance, Trouble Remedy

Page 11

SECTION 4 − MAINTENANCE & TROUBLESHOOTING

4-1. Routine Maintenance

Y Disconnect torch before maintaining.

 

40 Hours

 

 

Replace

Repair or

Clean and

replace

tighten weld

unreadable

cracked

terminals.

labels.

weld cable.

 

 

 

 

Replace cracked parts

 

 

 

 

Torch Body

Torch Cable

4-2.

Troubleshooting

 

 

NOTE

Before using troubleshooting table, check selection and preparation of tungsten electrode according to Section 5.

Trouble

Remedy

 

 

 

 

Arc will not start. High frequency present

Check cable and work connections. Be sure weld circuit is complete (see Section 3-3).

and visible at the torch.

 

Check and be sure shielding gas is present.

 

 

 

Lack of high frequency; difficulty in es-

Select proper size and type of tungsten. Properly prepare tungsten according to Section 5.

tablishing arc.

 

Check cables and torch for cracks or bad connections. Be sure that torch cables are not close to any

 

 

grounded metal. Repair or replace necessary parts.

 

 

 

Check torch consumables. Be sure collet and collet body are correctly installed and tightened (see Sec-

 

tion 3-1).

 

 

 

Check welding power source High Frequency control, and if necessary, check and adjust spark gaps.

 

 

Torch gas valve not working properly (if

Have Factory Authorized Service Station/Service Distributor check valve.

applicable).

 

 

 

No shielding gas flow from torch.

Be sure valves on gas supply are open.

 

 

 

Check cable for kinks or blockage.

 

 

 

Check and tighten all gas supply fittings.

 

 

 

Check cables and torch for cracked insulation or bad connections. Repair or replace (see Section 4-1).

 

 

 

Make sure collet is installed correctly (see Section 3-1).

 

 

Tungsten electrode oxidizing and not re-

Shield weld zone from drafts.

maining bright after conclusion of weld.

 

Increase postflow time.

 

 

 

 

Increase gas flow rate. Check manufacture’s recommendations.

 

 

 

Check and tighten all gas fittings.

 

 

 

Check gas valve and flow meter/regulator.

 

 

 

Select proper size and type of tungsten. Properly prepare tungsten (see Section 5).

 

 

Excessive tungsten electrode con-

Select proper size and type of tungsten. Properly prepare tungsten according to Section 5.

sumption.

 

Check polarity setting on welding power source (see welding power source Owner’s manual).

 

 

 

 

Check for proper gas flow rate. Check manufacture’s recommendations.

 

 

 

If torch is water cooled, check torch and cables for water leaks. Repair or replace if necessary (see Sec-

 

tion 4-1).

 

 

OM-1600 Page 7

Image 11
Contents Description OM-1600199 525EProcesses From Miller to You Table of Contents Page Gtaw Torch Hazards −SAFETY Precautions for Gtaw Torches − Read Before UsingSymbol Usage About Pacemakers EMF InformationDuty Cycle − SpecificationsSpecifications Exceeding Rated Amperage can damage torch and void warrantyInstalling Tungsten − InstallationRequired Torch Parts And Torch Assembly International Style Connector AssemblyOperating Torch Gas Valve Connecting TorchConnecting Torch With One-Piece Cable ConnectionsConnecting Torch With Flow-Through Type Connection Connecting Torch With Two-Piece CableDisconnect torch before maintaining Hours − Maintenance & TroubleshootingRoutine Maintenance TroubleshootingEssary 50-150 Amperage Range Gas Type PolarityPreparing Tungsten For Conventional AC Welding − Guidelines for TIG Welding GtawPreparing Tungsten Electrode For Welding Positioning The TorchTungsten With Filler Rod Torch Movement During WeldingPositioning Torch Tungsten For Various Weld Joints Tungsten Without Filler RodComplete Torch Assembly − Parts ListEnglish 194 ADAPTER, intl style flow through Torch Models With Gas Valve 17V12R Page Page Support ServiceMiller Electric Mfg. Co Owner’s Record