Miller Electric 1250, 1000 Connecting Input Power, Welding Power Source Input Power Connections

Page 24

4-13. Connecting Input Power

 

 

= GND/PE Earth Ground

9

 

 

 

 

 

8

 

 

 

11

 

 

 

10

 

 

 

 

2

4

 

 

 

 

7

 

 

 

 

1

 

 

 

IMPORTANT

 

 

6

Input Terminal Board

 

 

 

 

 

L1 (U)

 

 

7

L2 (V)

 

4

 

L3 (W)

 

 

 

 

5

4

 

 

 

3

 

 

 

 

 

 

GND/ PE Earth Ground

Tools Needed: 3/8 in

3/8 in

YInstallation must meet all National and Local Codes − have only quali- fied persons make this installation.

YDisconnect and lockout/tagout in- put power before connecting input conductors from unit.

YMake input power connections to the welding power source first.

YAlways connect green or green/ yellow conductor to supply grounding terminal first, and never to a line terminal.

See rating label on unit and check input voltage available at site.

1Input Power Conductors (Customer Supplied Cord)

Select size and length of conductors using Section 4-11.Conductors must comply with national, state, and local electrical codes. If applicable, use lugs of proper amperage capacity and correct hole size.

Welding Power Source Input Power Connections

2 Strain Relief

Route conductors (cord) through strain re- lief and tighten screws.

3Machine Grounding Terminal

4Green Or Green/Yellow Grounding Conductor

5Reed Switch (Ground Current Sensor) (Optional)

Connect green or green/yellow grounding conductor to welding power source grounding terminal first. If unit is equipped with optional ground current sensor, route grounding conductor through reed switch two times and connect to grounding termi- nal.

6Welding Power Source Line Terminals

7Input Conductors L1 (U), L2 (V) And L3 (W)

Connect input conductors L1 (U), L2 (V) and L3 (W) to welding power source line terminals.

Close and secure access door on welding power source.

Disconnect Device Input Power Con- nections

8Disconnect Device (switch shown in OFF position)

9Disconnect Device (Supply) Grounding Terminal

Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.

10 Disconnect Device Line Terminals

Connect input conductors L1 (U), L2 (V) And L3 (W) to disconnect device line terminals.

11 Overcurrent Protection

Select type and size of overcurrent protec- tion using Section 4-11(fused disconnect switch shown).

Close and secure door on line disconnect device. Remove lockout/tagout device, and place switch in the On position.

Ref. 800 103-C / Ref. 802 295

OM-2223 Page 20

Image 24 Contents
OM-2223 ProcessesDescription From Miller to You Table of Contents Directives StandardsSymbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers Identifie un message de sécurité particulier − Consignes DE Sécurité − À Lire Avant UtilisationLE Soudage peut causer un incen- die ou une explosion LES Particules Projetées peu- vent blesser les yeuxLES Pièces Chaudes peuvent cau- ser des brûlures graves LE Bruit peut affecter l’ouïeRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut Faire LES Pièces Mobiles peuvent cau- ser des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiquesConsignes relatives aux stimulateurs cardiaques General Precautionary Label − DefinitionsNameplate Safety Symbols Input Connection LabelElectric Shock And Airflow Label ? aSymbol Definitions Manufacturer’s Rating Label For CE ProductsI1max I1eff− Installation SpecificationsDuty Cycle And Overheating CC Mode CV Mode Volt-Ampere CurvesSelecting a Location Movement Location And AirflowDimensions And Weights DimensionsWeight Be careful when placing or moving unit over uneven surfaces Turn Off power before connecting to receptacle Tipping VAC Receptacle And Circuit BreakersWeld Output Terminals And Selecting Cable Sizes Remote 14 Receptacle And Terminal Strip 1T InformationConnecting Remote Control Electrical Service GuideAmpere Rated Welding Output Placing Jumper Links 50 Hz Input VoltageConnecting Input Power Welding Power Source Input Power ConnectionsDisconnect Device Input Power Con- nections Work like a Pro Dimension 1000 Nameplate Dimension 1250 Nameplate − OperationControls Amperage/Voltage Adjustment Control − Maintenance & Troubleshooting Routine MaintenanceDisconnect power before maintaining Fuse F1Troubleshooting Trouble Remedy− Electrical Diagrams Circuit Diagram for 60 HZ ModelCircuit Diagram for 50 HZ Model Hz Models Only Main Assembly PLG14Panel, Front w/Components -1Item PC1 207 Rectifier, SCR Main -1Item Panel, Rear w/Components -1Item Page Service SupportOwner’s Record Miller Electric Mfg. Co