Miller Electric 251 NT manual Principal Safety Standards, EMF Information, About Pacemakers

Page 8

H.F. RADIATION can cause interference.

DHigh-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.

DHave only qualified persons familiar with electronic equipment perform this installation.

DThe user is responsible for having a qualified electrician prompt- ly correct any interference problem resulting from the installa- tion.

DIf notified by the FCC about interference, stop using the equipment at once.

DHave the installation regularly checked and maintained.

DKeep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.

ARC WELDING can cause interference.

DElectromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots.

DBe sure all equipment in the welding area is electromagnetically compatible.

DTo reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

DLocate welding operation 100 meters from any sensitive elec- tronic equipment.

DBe sure this welding machine is installed and grounded according to this manual.

DIf interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.

1-5. Principal Safety Standards

Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126

Safety and Health Standards, OSHA 29 CFR 1910, from Superinten- dent of Documents, U.S. Government Printing Office, Washington, D.C. 20402.

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202.

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018.

Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

1-6. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from operator as practical.

5.Connect work clamp to workpiece as close to the weld as possi- ble.

About Pacemakers:

Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended.

OM-486 Page 4

Image 8
Contents Description OM-486Processes From Miller to You Table of Contents Page Symbol Usage Arc Welding HazardsElectric Shock can kill ARC Rays can burn eyes and skinEngine Hazards Battery Explosion can Blind Moving Parts can cause injuryEngine Exhaust Gases can kill Engine Heat can cause firePrincipal Safety Standards EMF InformationRadiation can cause interference ARC Welding can cause interferenceSignification des symboles Consignes DE SÉ Curité Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Soudage peut provoquer un in- cendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES PIÈ CES Chaudes peuvent provoquer des brû lures graves LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent provoquer des blessures ’EXPLOSION DE LA Batterie peutLA Chaleur DU Moteur peut pro- voquer un incendie LA Chute DE L’APPAREIL peut blesserPrincipales normes de sé curité Information sur les champs é lectromagné tiquesLE Soudage À L’ARC risque de provoquer des interfé rences Consignes relatives aux stimulateurs cardiaquesSpecifications Symbol DefinitionsWeld, Power, And Engine Specifications DefinitionsFuel Consumption Dimensions, Weights, and Operating AnglesDimensions Duty Cycle Auxiliary Power CurveExceeding duty cycle can damage unit and void warranty CC/DC Mode CV/DC ModeCC/AC Mode Volt-Ampere CurvesEngine Prestart Checks InstallationInstalling Welding Generator Activating The Dry Charge Battery If Applicable Do not overfill battery cellsRead and follow all instruc ChargerConnecting The Battery Installing Exhaust PipeConnecting To Weld Output Terminals Connect negative cable lastSelecting Weld Cable Sizes Remote 14 Receptacle Information100 ft 30 m Or Less 10 100% Duty CycleAdjusting MIG Weld Puddle Consistency Stop engineTo wet out weld puddle To stiffen weld puddleDC Polarity/AC Switch Do not switch under loadRemote Amperage/Voltage Switch Operating Welding GeneratorRemote Amperage/Voltage Control Weld Current 120 240 Auxiliary Power Receptacles And Circuit BreakersOperating Auxiliary Equipment Optional Auxiliary Power Receptacles Gfci Receptacle OptionMaintenance and Troubleshooting Maintenance Label Stop engine and let cool Servicing Air CleanerServicing Optional Spark Arrestor Changing Engine Oil, Oil Filter, And Fuel Filter Weld/Power Speed Adjustment Adjusting Engine SpeedIdle Speed Adjustment Troubleshooting Overload ProtectionWelding Trouble RemedyLow weld output Check control settings Check and clean air cleaner as necessary see SectionCheck and adjust engine speed see Section See engine manualAuxiliary Power Check receptacle wiring and connectionsEngine Check governor according to engine manualElectrical Diagram Circuit Diagram For Welding GeneratorST-190 578-B Grounding Generator To Truck Or Trailer Frame Auxiliary Power GuidelinesSelecting Equipment Grounding When Supplying Building Systems How Much Power Does Equipment Require?Earth ground if supplying Amperes x Volts = WattsApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP xTypical Connections To Supply Standby Power 240 120 GroundSelecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes24-Fig Parts ListMain Assembly Dia Part Description Mkgs Quantity Panel, Front w/Components Panel, Front w/Components -1 Item Generator -1 Item Page Page Page Support ServiceYour distributor also gives Owner’s Record Miller Electric Mfg. Co

251 NT specifications

The Miller Electric 251 NT is a highly regarded multi-process welding machine known for its versatility and advanced features, making it an ideal choice for professionals in various industries. With its robust construction and user-friendly interface, the 251 NT provides an efficient solution for MIG, TIG, and Stick welding applications.

One of the main features of the Miller Electric 251 NT is its impressive output range, which allows for welding on a variety of materials and thicknesses. It delivers up to 250 amps of power, enabling users to tackle both thin and thick metals with ease. Additionally, the machine is equipped with an Auto-Set feature, which automatically adjusts the welding settings according to the material thickness and type. This eliminates the guesswork, significantly enhancing productivity and reducing setup time.

Another noteworthy aspect of the Miller Electric 251 NT is its inverter technology. This advanced technology provides a compact, lightweight design without compromising performance. Inverter technology allows for greater energy efficiency, resulting in reduced operational costs over time. The 251 NT also features a Duty Cycle of 60% at 250 amps, which means it can handle demanding tasks while maintaining optimal performance.

The Miller Electric 251 NT is designed with user convenience in mind. The intuitive digital display offers clear visibility of the settings, allowing welders to make quick adjustments. Furthermore, the machine includes a built-in memory function to store frequently used parameters, enhancing workflow efficiency.

Safety is a key component of the 251 NT's design. It comes equipped with various safety features, including overload protection and a thermal overload warning system. These features ensure that the machine operates within safe limits, minimizing the risk of damage and ensuring longevity.

In terms of portability, the Miller Electric 251 NT's lightweight design and integrated handle make it easy to transport between job sites. The durable housing protects the internal components, making it suitable for rigorous use in demanding environments.

Overall, the Miller Electric 251 NT offers a combination of power, flexibility, and ease of use, making it a top choice for welders looking to enhance their capabilities across multiple welding processes. Whether in a professional shop or on a construction site, the 251 NT stands out as a reliable and efficient welding solution.