Simer Pumps 3988, 3985, 3983 Specifications and Safety, Description, General Safety Information

Page 2

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home sumps. The permanent split capacitor motor is oil filled, sealed for cooler running, and has automatic-reset thermal protection. Ball bearings on the motor shaft never need lubrication. The power cord is a 3-wire, grounding-type cord.

SPECIFICATIONS

Power supply

115V, 60 HZ., 15 Amp Circuit

Liquid Temp. Range

32°F to 70°F(0°-21°C)

Individual Branch Circuit Required (min.)

.........15 Amps

Discharge:

1-1/2" Female NPT

This pump is designed for use in a residential sump only. Pump water only with this pump.

NOTICE: This unit is not designed as a waterfall or foun- tain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.

Do not use where water recirculates.

Not designed for use as a swimming pool drainer.

NOTICE: Read this Owner’s Manual for installation, operation, and safety information.

GENERAL SAFETY INFORMATION

Your automatic sump pump should give years of trouble-free service when correctly installed, main- tained, and used. However, interruption of power to the pump, dirt/debris in the sump, flooding that exceeds the pump’s capacity, electrical or mechanical failure in the pump, etc., may prevent normal pump operation. To help prevent damage from flooding, purchase a secondary AC sump pump, a DC backup sump pump, and/or a high water alarm. See the “Troubleshooting Chart” in this manual for informa- tion about common sump pump problems and reme- dies. For more information,call Simer customer service at 1-800-468-7867.

Hazardous voltage. To reduce the risk of hazardous or fatal electrical shock, follow instructions A through D, below:

A.This pump has an approved 3-conductor power cord with 3-prong, grounding-type plug. Connect the pump only to a properly grounded, 3-prong outlet. If the sump pump circuit has a 2-prong out- let, replace it with a grounded 3-prong outlet installed according to code.

B.Unplug the pump before handling or servicing it. If your basement floor is wet, turn off all power before walking on it. If the shut-off box is in the basement, call your electric company or hydro authority to shut off service to the house, or call your local fire department for instructions. After turning off the power, remove the pump for service.

C.Protect the electrical cords from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cords. Replace damaged or worn cords.

D.Do not lift the pump by the power cord.

Plastic pipe glue is extremely flammable. Follow the glue manufacturer’s instructions when assembling glued plastic pipe.

Burn hazard. Modern motors may run hot. Allow 20 minutes to cool before handling.

1.Know the pump application, limitations, and potential hazards.

2.Do not use this pump in water with fish present.

3.Drain the system completely before servicing it.

4.To prevent a flexible discharge line from whip- ping, which could cause injury or damage, fasten it down before starting the pump.

5.Before each use, check any hoses in the system for weakness or wear. Make certain that all con- nections are tight.

6.Periodically inspect the sump, the pump, and the piping for debris and foreign objects. Perform routine cleaning as required.

7.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep your work area clean, uncluttered and properly lighted; put away all unused tools and equipment.

c.Keep visitors at a safe distance from the work area.

d.Make workshop child-proof with padlocks and master switches. Remove any starter keys.

8.This pump installation must meet all applicable laws, codes, and ordinances.

Tools Required:

Pipe wrench, Strap Wrench, or Slip-Joint Pliers, Hacksaw,

Screw Driver, File or Sandpaper

Materials Required:

1-1/2" ABS or PVC Pipe with Cement to match Threaded Adapter (Pipe to Pump)

Check Valve – Purchase a check valve that goes in the discharge line or in the pump discharge. If your check valve does not have a 1/8" anti-airlock hole, drill one in the discharge pipe just below the check valve. Be sure to install the check valve so that the flow will be away from the pump.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 2
Contents 3988 39843986 PhoneGeneral Safety Information Specifications and SafetySpecifications DescriptionInstallation 2B. Tighten the pipe into the pump hand tight + 1-1/2 turnsInstallation Operation PerformanceRepair Parts 3983, 3984 3985, 3986Troubleshooting Symptom Probable Causes Corrective ActionThread the new impeller onto the motor shaft as Impeller ReplacementShown left-hand thread tightens to the left Warranty Simer Limited WarrantyCaractéristiques et sécurité CaractéristiquesInstallation Installation Fonctionnement DébitsPièces de rechange Diagnostic des pannes Incidents Causes Possibles RemèdesRemplacement de l’impulseur Gauche pour le visserGarantie Garantie limitée SimerEspecificaciones Especificaciones y SeguridadDescripción Información General Sobre LA SeguridadInstalación 1A. Tamaño mínimo del sumideroFigura Operación DesempeñoPiezas de reuesto Localización de fallas Síntoma Causas Probables Medida CorrectivaReemplazo del Impulsor Se afloja hacia la derecha3988, 3995, 3997 De por vida GarantiaGarantia Limitada de Simer Page

3984, 3988, 3985, 3986, 3983 specifications

Simer Pumps, a brand renowned for quality and performance, has a variety of models that cater to different needs within the pumping industry. Among these, the models 3983, 3986, 3985, 3988, and 3984 stand out due to their unique features and innovative technologies.

The Simer 3983 is designed for efficiency and reliability, tailored for residential and light commercial applications. It boasts a robust thermoplastic construction, ensuring durability in even the most demanding environments. With a powerful motor capable of delivering impressive flow rates, the 3983 is ideal for general water transfer, drainage, and irrigation tasks. Its energy-efficient design not only reduces operational costs but also minimizes environmental impact.

The Simer 3986 is a versatile pump that excels in both submerged and above-ground applications. This model features a built-in float switch that allows for automatic operation, making it perfect for areas prone to flooding. Its corrosion-resistant materials ensure a long lifespan, while the quiet operation is an added advantage for residential settings. This model is frequently chosen for basement water removal and protecting properties from water damage.

The Simer 3985, on the other hand, is engineered specifically for heavy-duty tasks. This pump features an intensive-duty motor and is capable of handling larger volumes of water efficiently. Equipped with a durable cast iron construction, the 3985 is built to withstand tough conditions. It is particularly suitable for construction sites, dewatering tasks, and other industrial applications where performance is crucial.

The Simer 3988 is an advanced model that integrates smart technologies for enhanced functionality. Its digital control panel allows users to customize settings according to their specific needs, making it versatile for various applications. This model is also known for its low noise pollution and energy-saving capabilities, appealing to eco-conscious users. Its automatic shut-off feature prevents dry running, protecting the pump from damage.

Lastly, the Simer 3984 is designed with the homeowner in mind. This residential pump features a compact design that allows for easy installation in tight spaces. With its user-friendly interface and reliable performance, it is perfect for handling standby water removal during heavy rain or for irrigation purposes. Additionally, its lightweight frame facilitates easy transport and setup.

In summary, Simer Pumps offers a comprehensive selection of models like the 3983, 3986, 3985, 3988, and 3984, each tailored to meet specific needs ranging from residential to industrial applications. These pumps combine durability, advanced technology, and user-friendly features, making them an excellent choice for effective water management.