SETUP
Lamp
| You will need to install a lamp prior to the initial operation of the fixture. An ELC 250W halogen lamp | |
| is included. | |
Warning! | When replacing the lamp, please wait 15 minutes after powering down to allow the | |
| unit to cool down! Always disconnect from main power prior to lamp replacement. | |
| Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp | |
| with alcohol and wipe it with a lint free cloth before installation. | |
| LAMP INST ALLAT ION | |
| 1) | Remove the 2 screws nearest the top of the fixture on both sides for a total of 4 screws |
|
| removed. |
| 2) | Remove the top cover completely to expose lamp cage. |
| 3) | Make sure the lamp is no longer hot before handling. Hold the lamp by its base and slide it |
|
| upwards until it is free from the retaining clips. Disconnect lamp from lamp socket. |
| 4) | Connect a new lamp to the lamp socket and follow the same procedure as above to insert lamp |
|
| into lamp cage. |
| 5) | Replace top cover and screws. |
| 6) | No lamp alignment is necessary for this fixture. |
Remove Philips screws to remove unit top cover!
Unit with top cover removed and lamp exposed
Power
Your product is equipped with
| setting. |
Warning! | Verify that the power select switch on your unit |
| matches the line voltage applied. All fixtures must be |
| connected to circuits with a suitable Earth Ground. |
Slide switch up or down depending on your line voltage.
∙To determine the power requirements for a particular fixture,’s specificationssee the label chart. affixed to the back plate of the fixture or refer to the fixture
∙A fixture’s listed current rating is its average current draw under normal conditions.
∙All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
∙Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.