SETUP
Lamp
| The xenon 200 watt lamp comes |
Warning! | When replacing the lamp, please wait 15 minutes after powering down to allow the |
| unit to cool down! Always disconnect from main power prior to lamp replacement. |
| Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp |
| with alcohol and wipe it with a lint free cloth before installation. |
LAMP INSTALLATION
1) | Unscrew the three most left and right screws on the back of the | |
| carefully. The segment display can remain attached to the PCB during lamp replacement. | |
2) | Unscrew the three lamp wires from their respective terminals on the PCB as illustrated in Figure | |
| 3. You may need to clip the | |
| in order to free the lamp. |
|
3) | Slide lamp socket out of the thin metal plate one end at a time. | |
4) | Replace strobe with new lamp and | |
|
| |
| Top view |
Lamp side with 1 wire molded into ceramic base gets fastened to terminal labeled J3.
J3
J4
5)Replace front cover and screws.
Lamp side with 2 wires;
1. Wire molded into ceramic base is fastened to terminal labeled J4
2. Wire coiled around the envelope of the bulb gets fastened to terminal labeled J5.
J5
5 | Revision: |