Chicago Electric 66439 operating instructions Extension Cords, Symbology, See Table a, 25’ 50’ 75’

Page 6

Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using exten- sion cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and pos- sible tool damage.

(See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

4.When using more than one exten- sion cord to make up the total length, make sure each cord contains at least the minimum wire size required.

(See Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is prop- erly wired and in good electrical con- dition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and

damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

EXTENSION CORD

 

LENGTH

 

AMPERES

 

 

25’

50’

75’

100’

150’

(at full load)

 

 

 

 

 

 

 

 

 

 

 

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

Symbology

Double Insulated

 

Canadian Standards Association

 

 

 

Underwriters Laboratories, Inc.

 

 

V~

Volts Alternating Current

A

Amperes

 

 

 

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)

SKU 66439

For technical questions, please call 1-800-444-3353.

Page 6

Image 6
Contents For technical questions or replacement parts, please call Distributed exclusively by Harbor Freight ToolsGeneral Safety Rules Important Safety rules Save This ManualFor technical questions, please call General Safety Rules Work area safetyElectrical safety Use safety equipment. AlwaysWear eye protection. Safety Power source before making anyGrounded Tools Tools with Three Prong Plugs ServiceGrounding Prong Plug and OutletSee Table a SymbologyExtension Cords 25’ 50’ 75’Light Assembly SpecificationsSet Up Instructions UnpackingStand Assembly Figure BMaintenance Servicing Cleaning, maintenance, LubricationOperating Instructions Assembly diagram Part Description QtySKU For technical questions, please call Limited 90 DAY Warranty Record Product’s Serial Number Here