Cleaning Methods

Warning

Always remove the power plug from the wall outlet.

 

Electrolyzed Water Unit/Tank

Remove the cover, tank, and

2

1 electrolyzed water unit.

 

¡Lift the tank straight up.

 

 

Cover

Tank

Electrolyzed Water Unit

[Rear]

Note:

Remove the electrolyzed water cover.

¡Remove the cover from both sides (lift to remove the electrolyzed water cover).

HookLift

Electrolyzed

Water Cover

Hook

¡Use a towel to ensure that the floor does not get wet from water attached to the electrolyzed water unit and tank.

3 Wash the tank and electrolyzed water cover with water.

¡Rinse clean with water. Use a toothbrush to remove the dirt if extremely dirty.

4 In the event of limescale build up on the Sterile-Electrolytic Mist Generator, clean with white vinegar to remove the limescale. Do not use water as this may cause the unit to malfunction.

Cotton

Swab

Sterile-Electrolytic

Mist Generator

5

Wipe off any water and dry completely.

Re-assemble the electrolyzed water

 

6 unit and replace.

¡Place the side tabs of the electrolyzed water unit cover to the bottom and press the hooks on both sides.

Hooks

 

 

 

Tab

 

 

 

Hook

7

Close the cap on the tank and replace.

8

Replace the cover.

Cap

¡Push from above.

Cover

Note:

¡Do not wash any other components except the tank and electrolyzed water unit. This may cause an electric shock or malfunction.

¡Do not use detergents. This may cause malfunctions. E-13

Image 14
Contents ABC-VW24A Precautions This may cause a fire Part Names and Functions Odor Sensor Power Mist LampClean Indicator Electrolyzed Water LampOperating Unit Filter Replacement Lamp RedFilter Reset Button Add Water Lamp RedRemove the front cover Installing the FilterPreparations Before Use Remove the pre-filter filterReplenishing the Water WaterUnit Installation Unit InstallationAdjusting the Sensitivity of the Odor Sensor Adjust the sensor sensitivity adjustment slide tabOperation of the Odor Sensor Press the power on/off buttonMethod of Use Automatic OperationPower Mist Mode Timer OperationStopping Operation Electrolyzed WaterSelect Brightness Bright Dark OffReplacing the Filter Replacement PeriodsRefer to page E-5 regarding replacement methods Pre-filter Cleaning MethodsUnit FilterElectrolyzed Water Unit/Tank Troubleshooting SpecificationsPrecautions Précautions Ceci risquerait de causer un incendie Ventilateur Nom et fonctions des piècesIndicateur de propreté Filtre Préfiltre Couvercle avantUnité de commande Installation du filtre Préparatifs avant l’utilisationRemplissage du réservoir d’eau EauRéglage de la sensibilité du détecteur d’odeurs Installation de l’appareilInstallation de l’appareil ’extérieur de l’appareil, et e soulevez-leFonctionnement automatique Méthode d’utilisationFonctionnement du détecteur d’odeurs Appuyez sur l’interrupteur d’alimentationFonctionnement par minuterie Mode de brume électriqueFonctionnement manuel Heure 2 heures 8 heuresArrêt de l’opération Eau électrolyséeSélection de la luminosité Brillant Pâle ÉteintRemplacement du filtre Intervalles de remplacementFiltre AppareilPréfiltre Détecteur d’odeursRéservoir/unité d’eau électrolysée Remontez l’unité d’eau électrolysée et remettez-la en placeDépannage SpécificationsPrecautions Sanyo North America Corporation Consumer Solutions Division

ABC-VW24A specifications

The Sanyo ABC-VW24A is a highly efficient and advanced air conditioner that offers a perfect balance of comfort and energy savings. Designed to cater to various indoor environments, this model stands out for its impressive array of features and cutting-edge technologies, making it a popular choice among homeowners and businesses alike.

One of the main highlights of the Sanyo ABC-VW24A is its inverter technology, which enables the unit to adjust its power output according to the cooling needs of the space. This results in significantly lower energy consumption compared to traditional air conditioning systems, which can lead to reduced electricity bills. The inverter's ability to maintain a consistent temperature also provides a more stable and comfortable environment, eliminating the fluctuations associated with conventional units.

In addition to its inverter technology, the ABC-VW24A is equipped with a multi-stage filtration system. This feature enhances indoor air quality by removing dust, allergens, and other pollutants from the air. The filters are easy to clean and replace, ensuring that the unit operates efficiently while helping users maintain a healthier living space.

Moreover, the Sanyo ABC-VW24A boasts an eco-friendly refrigerant that complies with international standards for environmental safety. This refrigerant not only minimizes the unit's carbon footprint but also ensures effective cooling performance, highlighting Sanyo’s commitment to sustainability.

User convenience is at the forefront of the ABC-VW24A’s design. The air conditioner comes with a user-friendly remote control, allowing easy temperature adjustments and settings from various locations within the room. Additionally, the programmable timer feature enables users to schedule operations according to their routines, further optimizing energy use.

The Sanyo ABC-VW24A is noted for its quiet operation, allowing users to enjoy a tranquil environment without the disruptive noise often associated with air conditioning units. The sleek design of the unit also complements various interior designs, making it a stylish addition to any space.

Overall, the Sanyo ABC-VW24A is a sophisticated air conditioning solution that excels in energy efficiency, air purification, and user comfort, making it a standout option for anyone looking to improve their indoor climate.