Dell T5610 owner manual Troubleshooting Your Computer, Diagnostic LEDs

Page 59

6

Troubleshooting Your Computer

You can troubleshoot your computer using indicators like Diagnostic Lights, Beep Codes, and Error Messages during the operation of the computer.

Diagnostic LEDs

NOTE: The diagnostic LEDs only serve as an indicator of the progress through the Power-On Self Test (POST) process. These LEDs do not indicate the problem that caused the POST routine to stop.

The diagnostic LEDs are located on the front of the chassis next to the power button. These diagnostic LEDs are only active and visible during the POST process. Once the operating system starts to load, they turn off and are no longer visible.

Each LED has two possible states of OFF or ON. The most significant bit is labeled with the number 1, and the other three are labeled 2, 3, and 4, as you go down or across the LED stack. The normal operating condition after POST is for all four LEDs to be ON and then turn off as the BIOS hands control over to the operating system.

NOTE: The diagnostic lights will blink when the power button is amber or off, and will not blink when it is white.

Table 13. POST Diagnostic LED Patterns

Diagnostic LEDs

• The computer is either turned off or is not receiving power

• The computer is booted and operating normally.

PCI device configuration activity is in progress or PCI device failure was detected.

If the computer is turned off , connect the AC power-supply and power-on the computer.

Remove all peripheral cards from the PCI and PCI-E slots and reboot the computer. If the computer boots, add the peripheral cards back one by one until you find the bad one.

A possible processor failure has

Re-seat the processor.

occurred.

 

Memory modules are detected, but a

• If two or more memory modules

memory power failure has occurred.

are installed, remove the modules,

 

then reinstall one module and re-

 

start the computer. If the

 

computer starts normally,

 

continue to install additional

 

memory modules (one at a time)

 

until you have identified a faulty

 

module or reinstalled all modules

 

without error. If only one memory

 

module is installed, try moving it to

 

a different DIMM connector and

 

re-start the computer.

59

Image 59
Contents Regulatory Model D01T Regulatory Type D01T003 Page Contents Technical Specifications Contacting Dell System SetupDiagnostics Troubleshooting Your ComputerBefore Working Inside Your Computer Working on Your ComputerClick Shut Down Turning Off Your ComputerAfter Working Inside Your Computer Page Page Recommended Tools Removing and Installing ComponentsSystem Overview Removing the Power Supply Unit PSUInstalling the Power Supply Unit PSU Removing the Cover Removing the Front Bezel Installing the CoverRemoving the Optical Drive Installing the Front BezelPage Page Removing the Hard Drive Installing the Optical DriveRemoving the Thermal Sensor Installing the Hard DriveInstalling the Thermal Sensor Removing the Input/Output I/O Panel Installing the Input/Output I/O Panel Removing the Memory Installing the Air TunnelRemoving the Air Tunnel Installing the Coin-Cell Battery Installing the MemoryRemoving the Coin-Cell Battery Removing the Heatsink Removing the Heatsink Fan Installing the HeatsinkInstalling the Heatsink Fan Removing the Processor Removing the System Fan Installing the ProcessorPage Page Page Page Removing the PSU Card Installing the System FanPage Removing the Speaker Installing the PSU CardInstalling the Speaker Removing the System Board Page Installing the System Board System Board Components Page Page Memory Module Guidelines Power Supply Unit PSU LockAdditional Information Page Keys Navigation System SetupBoot Sequence Navigation KeysAdvanced Boot Options System Setup OptionsBoot Sequence Boot List OptionSata Operation Option Description Date/TimeOption Description Integrated NIC Serial PortPCI Buses Default Default Setting All drives are enabledUSB Configuration PCI Bus ConfigurationPassword Change Strong PasswordPassword Bypass Disabled DefaultOption Description Multi Core Support Admin Setup LockoutOption Description Secure Boot Enable Power Off Default Default Setting Enable Intel SpeedStepDefault Setting Enable Intel TurboBoost Option Description AC RecoveryFan Speed Control Keyboard ErrorsFastboot Option Description Deep Sleep ControlUpdating the Bios Computer System and Setup PasswordDisabling a System Password Page Enhanced Pre-Boot System Assessment ePSA Diagnostics DiagnosticsPage Diagnostic LEDs Troubleshooting Your ComputerRe-seat all power and data cables Error Message Error MessagesErrors That Do Not Halt Your Computer Error Message Page Feature Specification Technical SpecificationsFeature PCI SLOT1 USB T7610 Serial With the system board or power supply Feature Specification Codes Cm/sec 20 in/sec Page Contacting Dell