Cisco Systems ASR 903 manual OL-25178-04

Page 34

Chapter 2 Preparing for Installation

Safety Guidelines

Warning Do not use this product near water; for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement, or near a swimming pool. Statement 1035

Warning Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Statement 1036

Warning Before opening the unit, disconnect the telephone-network cables to avoid contact with telephone-network voltages. Statement 1041

Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector or 2) while the housing is open, or both. Statement 1043

Warning This product requires short-circuit (overturned) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045

Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046

Warning Never install an AC power module and a DC power module in the same chassis. Statement 1050

Warning Failure to securely tighten the power and relay connector captive screws can result in an electrical arc if the connector is accidentally removed. Statement 1058

Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.

Warning If you connect or disconnect the console cable with power applied to the switch or any device on the network, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. To verify switch operation, perform POST on the switch in a nonhazardous location before installation. Statement 1065

Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074

Cisco ASR 903 Router Hardware Installation Guide

2-6

OL-25178-04

 

 

Image 34
Contents Cisco ASR 903 Router Hardware Installation Guide Page N T E N T S Site Planning RSP Installation Pinouts Fan Tray LEDs Viii Document Audience Document Revision HistoryRevision Date Change Summary Title Description Document OrganizationDocument Conventions Convention IndicationObtaining Documentation and Submitting a Service Request Xii Cisco ASR 903 Router Features Cisco ASR 903 Router OverviewSystem Specifications Cisco ASR 903 Router Chassis DesignPower Supply Features Dying Gasp DC Power SpecificationsRedundancy Status LEDsAC Power Specifications Fan TrayRSP Modules 2shows the fan traySupported RSPs Supported RSP FeaturesRSP Redundancy RSP Interfaces Network Timing InterfacesLabel Interface Interface Modules Gigabit Ethernet SFP Interface ModuleGigabit Ethernet RJ45 Interface Module 8 x 1 GE Gigabit Ethernet RJ45 Copper Interface ModuleGigabit Ethernet XFP Interface Module 1 x 10 GE Gigabit Ethernet XFP Interface ModuleDWDM-XFP-C ONS-XC-10G-EP T1/E1 Interface Module 16 x T1/E1 Interface ModuleOC-3 Interface Module 8shows the interface moduleInterface Numbering Temperature SensorSerial Number Label Location Regulatory Compliance Cisco ASR 903 Router Overview Regulatory CompliancePreparing for Installation Safety GuidelinesStandard Warning Statements Safety Precautions for Module Installation and Removal Safety with Electricity Page OL-25178-04 Preparing for Installation Safety Guidelines Power Supply Considerations Preventing ESD DamageSite Planning Checklist General PrecautionsSite Planning Site Selection Guidelines Physical CharacteristicsEnvironmental Requirements Air Flow Guidelines Air exhaust Room airAir Flow Guidelines for Enclosed Rack Installation Site Power GuidelinesFloor Loading Considerations Electrical Circuit Requirements Site Cabling GuidelinesHardware components Asynchronous Terminal Connections Interference ConsiderationsRack-Mounting Guidelines Precautions for Rack-MountingRack Selection Guidelines Locating for Safety Equipment Rack GuidelinesLocating for Proper Airflow Installation Checklist Verified Task DateReceiving the Cisco ASR 903 Router Creating a Site LogChassis-Lifting Guidelines Tools and EquipmentUnpacking and Verifying the Shipped Contents Component Description Installing the Router in a Rack PrerequisitesInstalling the Chassis Brackets Attaching Mounting Brackets for a 19-inch EIA RackInstalling the Router Chassis in the Rack Installing the Chassis in a 19-inch EIA RackInstalling the Chassis in a 300 mm Etsi Cabinet Attaching the Cable Management BracketsInstalling the Chassis Ground Connection Grounding lug 300 mm Etsi cabinetStripping a Ground Wire 10 Crimping a Ground Lug onto the Ground Wire Installing the Fan Tray Removing and Replacing the Fan Tray12 Detaching the Fan Tray RSP Installation 13 Fan Tray RemovalInstalling an RSP Module 14 Cisco ASR 903 Router RSP InstallationRemoving an RSP Module Hot-Swapping an RSP Module Interface Module Installation Installing an Interface ModuleRemoving an Interface Module Hot-Swapping an Interface ModuleOL-25178-04 Installing the Power Supply Preventing Power LossGuidelines for DC-Powered Systems Power Connection GuidelinesGuidelines for AC-Powered Systems Installing the DC Power Supply Installing the DC Power Supply ModuleInstalling the Terminal Block 16 Installing the DC Power Supply17 DC Power Supply with Lead Wires 18 Torquing the DC Power Supply Terminal Block Plug Screws Activating the DC Power Supply Removing and Replacing the DC Power Supply Supply has been removed or replacedInstalling the AC power Supply Installing the AC Power Supply ModuleRemoving and Replacing the AC Power Supply Activating the AC Power SupplyConnecting the Cisco ASR 903 Router to the Network Connecting Console CablesConnecting to the Serial Port using Microsoft Windows 2404 Connecting to the Console Port using Linux Connecting to the Console Port using Mac OSTo disconnect the OS X USB console from the Terminal window Installing the Cisco Microsoft Windows USB Device Driver Installing the Cisco Microsoft Windows XP USB DriverUsing the Add Remove Programs Utility Uninstalling the Cisco Microsoft Windows USB DriverUsing the Setup.exe Program Connecting to the Auxiliary Port Uninstalling the Cisco Microsoft Windows Vista USB Driver23 Connecting a Modem to the Cisco ASR 903 Router Installing and Removing SFP and XFP Modules Connecting a Management Ethernet CableConnecting a USB Flash Device Connecting Cables to the Bits Interface Connecting Timing CablesRemoving a USB Flash Device OL-25178-04 Connecting Cables to a GPS Interface Connecting Cables to the Input 10Mhz or 1PPS InterfaceConnecting Ethernet Cables Connecting T1/E1 cables Connecting Cables to SFP ModulesInstalling the Cable Connector Connecting Cables to the Patch Panel RJ45 Cable PinoutsConnecting the Fan Tray Alarm Port Recommended Patch PanelConnector and Cable Specifications OL-25178-04 Cisco ASR 903 Router Initial Configuration Checking Conditions Prior to System StartupPowering Up the Cisco ASR 903 Router Example 4-1 Loading the Default System Boot ImageCisco ASR 903 Router Hardware Installation Guide OL-25178-04 CPP Verifying the Front Panel LEDs Configuring the Cisco ASR 903 Router at StartupVerifying the Hardware Configuration Checking Hardware and Software CompatibilityUsing the Console Interface Configuring Global ParametersChecking the Running Configuration Settings Saving the Running Configuration to NvramSafely Powering Off the Cisco ASR 903 Router Pinouts Pin Signal Name Direction DescriptionBits Port Pinout Time of Day Port Pinout GPS Port PinoutMhz input and output 1PPS input and output Pin Signal Name Description Alarm Port PinoutConsole/Aux RJ45 RS232 Serial Port Pinout Board Telco Line Pins Signal Name Jack Pin Telco RX T1/E1 Port PinoutManagement Ethernet Port Pinout USB Console Port Pinout Fiber-Optic SpecificationsUSB Flash/MEM Port Pinout RSP LEDs LED SummaryColor/State Description two LEDs for eachT1/E1 port Interface Module LEDs Color/State DescriptionOC-3 Interface Module LEDs T1/E1 Interface Module LEDsPower Supply LEDs Fan Tray LEDsAlarm Conditions Alarm Type Alarm MeaningOL-25178-04 Site Log Date InitialsD E IN-2
Related manuals
Manual 132 pages 11.71 Kb