Grizzly H8219 instruction manual Using the Sander, Daily Maintenance

Page 7

EYE INJURY

HAZARD!

Wear protective

equipment when

using this tool.

Using the Sander

1.Plug the tool into compressed air regu- lated at 90 PSI.

2.Hold the sander firmly and press the throttle lever (Figure 3) to turn it ON.

3.Turn the regulator knob (Figure 3) to adjust the speed of the air sander.

LUNG/EAR

INJURY HAZARD! Wear protective equipment when using this tool.

ACCIDENTAL

START HAZARD! Disconnect before service or tool changes.

AIR PRESSURE

HAZARD! Never exceed max PSI rating for tool.

Throttle Lever

Regulator Knob

Figure 3. Sander controls.

4.Remove pressure on the throttle lever to stop the sander.

5.When the sandpaper loses its effective- ness, remove sandpaper from the pad, and replace with a new piece.

To avoid accidental starting, disconnect the sander from the air supply when it is not in use.

Model H8219 Air Orbital Sander

Daily Maintenance

The air sander MUST have 2-6 drops of oil dropped directly into the air fitting before and after each use.

A filter/lubricator/regulator set up is not recommended, as excess oil in the tool could spray onto the workpiece.

Run the sander for a few minutes to eject excess oil, then wipe the tool down with a rag and begin sanding. Oil the tool after use or storage.

These procedures should be done after each use:

Wipe the housing with a dry cloth, or blow off the dust and debris with com- pressed air.

Check for damage to tooling, hoses, housing or other accessories.