Sanyo SPW-FTR124EH56 Troubleshooting, Tips for Energy Saving, Trouble Possible Cause Remedy

Page 18

Troubleshooting

If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center.

Trouble

 

Possible Cause

 

 

Remedy

 

 

 

 

 

Air conditioner does not run at all.

1. Power failure.

 

1.

After a power outage, press ON/

 

 

 

 

 

OFF operation button on the

 

 

 

 

 

wired remote control unit.

 

2.

Leakage circuit breaker has

2.

Contact service center.

 

 

tripped.

 

 

 

 

3.

Line voltage is too low.

 

3.

Consult your electrician or dealer.

 

4.

Operation button is turned off.

4.

Press the button again.

 

5.

The wired remote control unit or

5.

Consult your dealer.

 

 

heat pump is malfunctioning.

 

 

 

 

(The inspection mark

and the

 

 

 

 

letters E, F, H, L, P in

 

 

 

 

 

combination with numbers

 

 

 

 

appear on the LCD of the wired

 

 

 

 

remote control unit.)

 

 

 

 

 

 

 

Compressor runs but soon stops.

1. Obstruction in front of condenser

1.

Remove obstruction.

 

 

coil.

 

 

 

 

 

 

 

 

Poor cooling (or heating)

1. Dirty or clogged air filter.

 

1.

Clean air filter to improve the

performance.

 

 

 

 

airflow.

 

2.

Heat source or many people in

2.

Eliminate heat source if possible.

 

 

room.

 

 

 

 

3.

Doors and/or windows are open.

3.

Shut them to keep the heat (or

 

 

 

 

 

cold) out.

 

4.

Obstacle near air intake or air

4.

Remove it to ensure good airflow.

 

 

discharge port.

 

 

 

 

5.

Thermostat is set too high for

5.

Set the temperature lower (or

 

 

cooling (or too low for heating).

 

higher).

 

6.

(Defrosting system does not work.)

6.

(Consult your dealer.)

 

 

 

 

 

 

Tips for Energy Saving

Avoid • Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.

Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.

Do • Always try to keep the air filter clean. (Refer to “Care and Cleaning”.) A clogged filter will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

NOTE

Should the power fail while the unit is running

If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same settings before the power was cut off.

18

Image 18
Contents Optional Controllers SPW-FTR124EH56 SPW-FTR164EH56 SPW-FTR184EH56Outdoor Units Sanyo Airconditioners Europe S.r.lSpecial Precautions Check of Density Limit Contents GeneralDimensions mm Wall installation HOW to Install the UnitFloor installation Under ceiling installation10 mm Outdoor unit Power supply Electrical WiringGeneral Precautions on Wiring Wire size Max. length Circuit capacityWiring System Diagrams 7P terminal boardOutdoor unit Indoor unit How to connect wiring to the terminal For stranded wiring Driver. FigFlaring Procedure with a Flare Tool HOW to Process TubingConnecting the Refrigerant Tubing Use of the Flaring Method DeburringTube diameter Tightening torque Tube thickness Approximate · cm 140 180 kgf Φ9.52 3/8Insulation material Precautions for Packed Valve OperationInsulating the Refrigerant Tubing Tubing Insulation After a tube has been insu Lated, never try to bend itFinishing the Installation Taping the TubesSpecial Remarks Installing the Control UnitAccessories Qty PartsAIR Clean Filter Accessory Supplied on Request Care and CleaningFilter Cleaning How to install the Air clean filterTips for Energy Saving TroubleshootingShould the power fail while the unit is running Trouble Possible Cause RemedyEntretien et nettoyage Filtre AIR a Haute Efficacite Accessoire SUR DemandeApplication de laccessoire Nettoyage DU FiltrePanne Cause possible Remède Guide de dépannageConseils pour économiser l’énergie RemarqueFilterreinigung Pflege und ReinigungHerausnehmen des Filters Luftfilter MIT GROßER Leistungsfähigkeit AUF AnfrageStörung Mögliche Ursache Abhilfe FehlersucheNützliche Hinweise für Energieeinsparung Bei einem Stromausfall während des Betriebs des GerätsLato presa d’aria e uscita d’aria unità interna Come applicare laccessorioCura e manutenzione Pulizia FiltroSuggerimenti per risparmiare energia Problema Causa probabile RimedioPrima di chiamare il tecnico Mancanza di corrente durante il funzionamento dell’unitàPrecaução Cuidados e limpezaLado de entrada e saída de ar unidade interior Limpeza do FiltroAvaria Causa possível Solução Resolução de problemasSugestões para poupar energia Se ocorrer uma falha de energia com a unidade a funcionarEnergoá Αντιµετώπιση προβληµάτων Limpieza DEL Filtro Cuidados y limpiezaLados de entrada y salida de aire Unidad interior Cómo se aplica el accesorioLocalización de averías Sugerencias para ahorrar energíaAvería Causa posible Remedio

SPW-FTR124EH56 specifications

The Sanyo SPW-FTR124EH56 is a cutting-edge air conditioning unit that combines energy efficiency with advanced technology, making it ideal for both residential and commercial applications. As a part of Sanyo's renowned product line, this model stands out for its sleek design and innovative features, aimed at providing optimal comfort throughout the year.

One of the key attributes of the SPW-FTR124EH56 is its inverter technology. This feature allows the compressor to adjust its speed dynamically, ensuring that the unit operates at the most efficient level for the given conditions. Consequently, this results in significant energy savings, with reduced power consumption compared to traditional air conditioning systems. The inverter technology also contributes to quieter operation, making it a perfect choice for living spaces, offices, and other environments where noise can be a concern.

The SPW-FTR124EH56 boasts a high cooling and heating capacity, making it versatile for varying climates. It is equipped with a powerful rotary compressor that ensures rapid temperature adjustment, providing relief during hot summer days and warmth during chilly winters. The unit's continuous heating capability allows it to maintain comfortable indoor temperatures even in extreme outdoor conditions.

Another notable feature is its advanced filtration system. The air conditioning unit comes with a built-in air purifying filter that effectively removes dust, allergens, and other airborne particles. This not only enhances indoor air quality but also contributes to the longevity of the unit by reducing the accumulation of dirt and debris.

The SPW-FTR124EH56 offers a user-friendly interface, with an intuitive remote control that allows for easy temperature adjustments and mode selections. Additionally, it features a programmable timer, enabling users to set the unit to operate at specific times, ensuring the space is always at a comfortable temperature without wasting energy when it’s unnecessary.

Moreover, the compact design of the Sanyo SPW-FTR124EH56 makes installation straightforward, allowing it to fit seamlessly into various settings. Its high energy efficiency rating highlights its environmental friendliness, appealing to eco-conscious consumers seeking sustainable climate control solutions.

In summary, the Sanyo SPW-FTR124EH56 is a highly efficient air conditioning unit that combines powerful performance with modern technology. With features like inverter technology, effective air filtration, and user-friendly controls, it is designed to provide year-round comfort while being mindful of energy consumption and environmental impact. Whether for home or office use, it represents an excellent choice for those seeking reliability and efficiency in climate control.