Sanyo SPW-FTR124EH56 operation manual Special Precautions

Page 2

IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operat- ing standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

This product is intended for professional use. Permission from the power supplier is required when installing an outdoor unit that is connected to a 16 A distribution network.

Pay close attention to all warning and caution notices given in this manual.

This symbol refers to a hazard or

WARNING unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or

CAUTION unsafe practice which can result in personal injury or product or

property damage.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance service, including fail- ure to follow the instructions in this document.

SPECIAL PRECAUTIONS

WARNING When Wiring

ELECTRICAL SHOCK CAN CAUSE

SEVERE PERSONAL INJURY OR DEATH.

ONLY A QUALIFIED, EXPERIENCED

ELECTRICIAN SHOULD ATTEMPT TO

WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this sys- tem. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inad- equate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause over- heating at connection points and a possible fire hazard.

When Transporting

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.

When Installing…

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

…In Moist or Uneven Locations

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

…In an area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

…In a Snowy Area (for Heat Pump-type Systems)

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

Ventilate the room well, in the event that is refrigerant gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas.

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free con- nection.

Check carefully for leaks before starting the test run.

NOTE

Depending on the system type, liquid and gas lines may

be either narrow or wide. Therefore, to avoid confusion

the refrigerant tubing for your particular model is speci-

fied as either “narrow” or “wide” than as “liquid” or “gas.”

When Servicing

Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

CAUTION

Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.

Confirm after installation that no refrigerant gas is leak- ing. If the gas comes in contact with a burning stove, gas water heater, electric room heater or other heat source, it can cause the generation of poisonous gas.

2

Image 2
Contents Optional Controllers SPW-FTR124EH56 SPW-FTR164EH56 SPW-FTR184EH56Outdoor Units Sanyo Airconditioners Europe S.r.lSpecial Precautions Check of Density Limit Contents GeneralDimensions mm Wall installation HOW to Install the UnitFloor installation Under ceiling installation10 mm Outdoor unit Power supply Electrical WiringGeneral Precautions on Wiring Wire size Max. length Circuit capacityWiring System Diagrams 7P terminal boardOutdoor unit Indoor unit How to connect wiring to the terminal For stranded wiring Driver. FigFlaring Procedure with a Flare Tool HOW to Process TubingConnecting the Refrigerant Tubing Use of the Flaring Method DeburringTube diameter Tightening torque Tube thickness Approximate · cm 140 180 kgf Φ9.52 3/8Insulation material Precautions for Packed Valve OperationInsulating the Refrigerant Tubing Tubing Insulation After a tube has been insu Lated, never try to bend itFinishing the Installation Taping the TubesSpecial Remarks Installing the Control UnitAccessories Qty PartsAIR Clean Filter Accessory Supplied on Request Care and CleaningFilter Cleaning How to install the Air clean filterTips for Energy Saving TroubleshootingShould the power fail while the unit is running Trouble Possible Cause RemedyEntretien et nettoyage Filtre AIR a Haute Efficacite Accessoire SUR DemandeApplication de laccessoire Nettoyage DU FiltrePanne Cause possible Remède Guide de dépannageConseils pour économiser l’énergie RemarqueFilterreinigung Pflege und ReinigungHerausnehmen des Filters Luftfilter MIT GROßER Leistungsfähigkeit AUF AnfrageStörung Mögliche Ursache Abhilfe FehlersucheNützliche Hinweise für Energieeinsparung Bei einem Stromausfall während des Betriebs des GerätsLato presa d’aria e uscita d’aria unità interna Come applicare laccessorioCura e manutenzione Pulizia FiltroSuggerimenti per risparmiare energia Problema Causa probabile RimedioPrima di chiamare il tecnico Mancanza di corrente durante il funzionamento dell’unitàPrecaução Cuidados e limpezaLado de entrada e saída de ar unidade interior Limpeza do FiltroAvaria Causa possível Solução Resolução de problemasSugestões para poupar energia Se ocorrer uma falha de energia com a unidade a funcionarEnergoá Αντιµετώπιση προβληµάτων Limpieza DEL Filtro Cuidados y limpiezaLados de entrada y salida de aire Unidad interior Cómo se aplica el accesorioAvería Causa posible Remedio Localización de averíasSugerencias para ahorrar energía

SPW-FTR124EH56 specifications

The Sanyo SPW-FTR124EH56 is a cutting-edge air conditioning unit that combines energy efficiency with advanced technology, making it ideal for both residential and commercial applications. As a part of Sanyo's renowned product line, this model stands out for its sleek design and innovative features, aimed at providing optimal comfort throughout the year.

One of the key attributes of the SPW-FTR124EH56 is its inverter technology. This feature allows the compressor to adjust its speed dynamically, ensuring that the unit operates at the most efficient level for the given conditions. Consequently, this results in significant energy savings, with reduced power consumption compared to traditional air conditioning systems. The inverter technology also contributes to quieter operation, making it a perfect choice for living spaces, offices, and other environments where noise can be a concern.

The SPW-FTR124EH56 boasts a high cooling and heating capacity, making it versatile for varying climates. It is equipped with a powerful rotary compressor that ensures rapid temperature adjustment, providing relief during hot summer days and warmth during chilly winters. The unit's continuous heating capability allows it to maintain comfortable indoor temperatures even in extreme outdoor conditions.

Another notable feature is its advanced filtration system. The air conditioning unit comes with a built-in air purifying filter that effectively removes dust, allergens, and other airborne particles. This not only enhances indoor air quality but also contributes to the longevity of the unit by reducing the accumulation of dirt and debris.

The SPW-FTR124EH56 offers a user-friendly interface, with an intuitive remote control that allows for easy temperature adjustments and mode selections. Additionally, it features a programmable timer, enabling users to set the unit to operate at specific times, ensuring the space is always at a comfortable temperature without wasting energy when it’s unnecessary.

Moreover, the compact design of the Sanyo SPW-FTR124EH56 makes installation straightforward, allowing it to fit seamlessly into various settings. Its high energy efficiency rating highlights its environmental friendliness, appealing to eco-conscious consumers seeking sustainable climate control solutions.

In summary, the Sanyo SPW-FTR124EH56 is a highly efficient air conditioning unit that combines powerful performance with modern technology. With features like inverter technology, effective air filtration, and user-friendly controls, it is designed to provide year-round comfort while being mindful of energy consumption and environmental impact. Whether for home or office use, it represents an excellent choice for those seeking reliability and efficiency in climate control.